Conductometric Immunosensor for Escherichia coli O157:H7 Detection Based on Polyaniline/Zinc Oxide (PANI/ZnO) Nanocomposite

被引:18
|
作者
Mutlaq, Sawsan [1 ]
Albiss, Borhan [2 ]
Al-Nabulsi, Anas A. [1 ]
Jaradat, Ziad W. [3 ]
Olaimat, Amin N. [4 ]
Khalifeh, Mohammad S. [5 ]
Osaili, Tareq [1 ,6 ]
Ayyash, Mutamed M. [7 ]
Holley, Richard A. [8 ]
机构
[1] Jordan Univ Sci & Technol, Dept Nutr & Food Technol, POB 3030, Irbid 22110, Jordan
[2] Jordan Univ Sci & Technol, Dept Appl Phys, Nanomat Lab, POB 3030, Irbid 22110, Jordan
[3] Jordan Univ Sci & Technol, Dept Biotechnol & Genet Engn, POB 3030, Irbid 22110, Jordan
[4] Hashemite Univ, Fac Appl Med Sci, Dept Clin Nutr & Dietet, POB 330127, Zarqa 13133, Jordan
[5] Jordan Univ Sci & Technol, Dept Basic Med Vet Sci, POB 3030, Irbid 22110, Jordan
[6] Univ Sharjah, Coll Hlth Sci, Dept Clin Nutr & Dietet, POB 27272, Sharjah, U Arab Emirates
[7] United Arab Emirates Univ UAEU, Coll Agr & Vet Med, Dept Food Sci, POB 15551, Al Ain, U Arab Emirates
[8] Univ Manitoba, Dept Food & Human Nutr Sci, Winnipeg, MB R3T 2N2, Canada
关键词
E. coli O157:H7; polyaniline; zinc oxide nanoparticles; immunosensor; antibody; GOLD NANOPARTICLES; SALMONELLA-TYPHIMURIUM; SENSITIVE DETECTION; POLYMER; BIOSENSOR; CAPTURE; MWCNT; AU;
D O I
10.3390/polym13193288
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A conductometric immunosensor was developed for the detection of one of the most common foodborne pathogens, Escherichia coli O157:H7 (E. coli O157:H7), by conductometric sensing. The sensor was built based on a polyaniline/zinc oxide (PANI/ZnO) nanocomposite film spin-coated on a gold electrode. Then, it was modified with a monoclonal anti-E. coli O157:H7 antibody as a biorecognition element. The fabricated nanostructured sensor was able to quantify the pathogens under optimal detection conditions, within 30 min, and showed a good detection range from 10(1) to 10(4) CFU/mL for E. coli O157:H7 and a minimum detection limit of 4.8 CFU/mL in 0.1% peptone water. The sensor efficiency for detecting bacteria in food matrices was tested in ultra-heat-treated (UHT) skim milk. E. coli O157:H7 was detected at concentrations of 10(1) to 10(4) CFU/mL with a minimum detection limit of 13.9 CFU/mL. The novel sensor was simple, fast, highly sensitive with excellent specificity, and it had the potential for rapid sample processing. Moreover, this unique technique for bacterial detection could be applicable for food safety and quality control in the food sector as it offers highly reliable results and is able to quantify the target bacterium.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] An Aptamer-Based Biosensor for Colorimetric Detection of Escherichia coli O157: H7
    Wu, Wenhe
    Zhang, Jie
    Zheng, Meiqin
    Zhong, Yuhong
    Yang, Jie
    Zhao, Yuhong
    Wu, Wenping
    Ye, Wei
    Wen, Jie
    Wang, Qi
    Lu, Jianxin
    PLOS ONE, 2012, 7 (11):
  • [32] A Label-Free Electrochemical Immunosensor Modified with AuNPs for Quantitative Detection of Escherichia coli O157:H7
    Yanyan Huang
    Zunyi Wu
    Guangying Zhao
    Wenchao Dou
    Journal of Electronic Materials, 2019, 48 : 7960 - 7969
  • [33] QCM immunosensor detection of Escherichia coli O157:H7 based on beacon immunomagnetic nanoparticles and catalytic growth of colloidal gold
    Shen, Zhi-Qiang
    Wang, Jing-Feng
    Qiu, Zhi-Gang
    Jin, Min
    Wang, Xin-Wei
    Chen, Zhao-Li
    Li, Jun-Wen
    Cao, Fu-Huan
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (07) : 3376 - 3381
  • [34] Electropolymerization of Stable Leucoemeraldine Base Polyaniline Film and Application for Quantitative Detection of Escherichia coli O157:H7
    Xiaoyan Mo
    Guangying Zhao
    Wenchao Dou
    Journal of Electronic Materials, 2018, 47 : 6507 - 6517
  • [35] Rapid detection of Escherichia coli O157:H7 by a fluorescent microsphere-based immunochromatographic assay and immunomagnetic separation
    Li, Qianru
    Yang, Yuexi
    Hu, Fei
    Cai, Yanxue
    Liu, Xiaoyun
    He, Xiaowei
    ANALYTICAL BIOCHEMISTRY, 2019, 564 : 32 - 39
  • [36] A sensitive and regenerative electrochemical immunosensor for quantitative detection of Escherichia coli O157:H7 based on stable polyaniline coated screen-printed carbon electrode and rGO-NR-Au@Pt
    Mo, Xiaoyan
    Wu, Zunyi
    Huang, Jianfeng
    Zhao, Guangying
    Dou, Wenchao
    ANALYTICAL METHODS, 2019, 11 (11) : 1475 - 1482
  • [37] Electrochemical genosensor based on gold nanostars for the detection of Escherichia coli O157:H7 DNA
    Razmi, Nasrin
    Hasanzadeh, Mohammad
    Willander, Magnus
    Nur, Omer
    ANALYTICAL METHODS, 2022, 14 (16) : 1562 - 1570
  • [38] Hierarchical cystine flower based electrochemical genosensor for detection of Escherichia coli O157:H7
    Pandey, Chandra Mouli
    Tiwari, Ida
    Sumana, Gajjala
    RSC ADVANCES, 2014, 4 (59): : 31047 - 31055
  • [39] A giant magnetoimpedance-based biosensor for sensitive detection of Escherichia coli O157:H7
    Yang, Zhen
    Sun, Xue-cheng
    Wang, Tao
    Lei, Chong
    Liu, Yan
    Zhou, Yong
    Lei, Jian
    BIOMEDICAL MICRODEVICES, 2015, 17 (01)
  • [40] A giant magnetoimpedance-based biosensor for sensitive detection of Escherichia coli O157:H7
    Zhen Yang
    Xue-cheng Sun
    Tao Wang
    Chong Lei
    Yan Liu
    Yong Zhou
    Jian Lei
    Biomedical Microdevices, 2015, 17