Conductometric Immunosensor for Escherichia coli O157:H7 Detection Based on Polyaniline/Zinc Oxide (PANI/ZnO) Nanocomposite

被引:18
|
作者
Mutlaq, Sawsan [1 ]
Albiss, Borhan [2 ]
Al-Nabulsi, Anas A. [1 ]
Jaradat, Ziad W. [3 ]
Olaimat, Amin N. [4 ]
Khalifeh, Mohammad S. [5 ]
Osaili, Tareq [1 ,6 ]
Ayyash, Mutamed M. [7 ]
Holley, Richard A. [8 ]
机构
[1] Jordan Univ Sci & Technol, Dept Nutr & Food Technol, POB 3030, Irbid 22110, Jordan
[2] Jordan Univ Sci & Technol, Dept Appl Phys, Nanomat Lab, POB 3030, Irbid 22110, Jordan
[3] Jordan Univ Sci & Technol, Dept Biotechnol & Genet Engn, POB 3030, Irbid 22110, Jordan
[4] Hashemite Univ, Fac Appl Med Sci, Dept Clin Nutr & Dietet, POB 330127, Zarqa 13133, Jordan
[5] Jordan Univ Sci & Technol, Dept Basic Med Vet Sci, POB 3030, Irbid 22110, Jordan
[6] Univ Sharjah, Coll Hlth Sci, Dept Clin Nutr & Dietet, POB 27272, Sharjah, U Arab Emirates
[7] United Arab Emirates Univ UAEU, Coll Agr & Vet Med, Dept Food Sci, POB 15551, Al Ain, U Arab Emirates
[8] Univ Manitoba, Dept Food & Human Nutr Sci, Winnipeg, MB R3T 2N2, Canada
关键词
E. coli O157:H7; polyaniline; zinc oxide nanoparticles; immunosensor; antibody; GOLD NANOPARTICLES; SALMONELLA-TYPHIMURIUM; SENSITIVE DETECTION; POLYMER; BIOSENSOR; CAPTURE; MWCNT; AU;
D O I
10.3390/polym13193288
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A conductometric immunosensor was developed for the detection of one of the most common foodborne pathogens, Escherichia coli O157:H7 (E. coli O157:H7), by conductometric sensing. The sensor was built based on a polyaniline/zinc oxide (PANI/ZnO) nanocomposite film spin-coated on a gold electrode. Then, it was modified with a monoclonal anti-E. coli O157:H7 antibody as a biorecognition element. The fabricated nanostructured sensor was able to quantify the pathogens under optimal detection conditions, within 30 min, and showed a good detection range from 10(1) to 10(4) CFU/mL for E. coli O157:H7 and a minimum detection limit of 4.8 CFU/mL in 0.1% peptone water. The sensor efficiency for detecting bacteria in food matrices was tested in ultra-heat-treated (UHT) skim milk. E. coli O157:H7 was detected at concentrations of 10(1) to 10(4) CFU/mL with a minimum detection limit of 13.9 CFU/mL. The novel sensor was simple, fast, highly sensitive with excellent specificity, and it had the potential for rapid sample processing. Moreover, this unique technique for bacterial detection could be applicable for food safety and quality control in the food sector as it offers highly reliable results and is able to quantify the target bacterium.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Electrochemical aptasensor for Escherichia coli O157:H7 bacteria detection using a nanocomposite of reduced graphene oxide, gold nanoparticles and polyvinyl alcohol
    Qaanei, Masood
    Taheri, Ramezan Ali
    Eskandari, Khadijeh
    ANALYTICAL METHODS, 2021, 13 (27) : 3101 - 3109
  • [22] Rapid detection of Escherichia coli O157:H7 spiked into food matrices
    Shriver-Lake, Lisa C.
    Turner, Stephanie
    Taitt, Chris R.
    ANALYTICA CHIMICA ACTA, 2007, 584 (01) : 66 - 71
  • [23] Electrochemical biosensors for rapid detection of Escherichia coli O157:H7
    Xu, Meng
    Wang, Ronghui
    Li, Yanbin
    TALANTA, 2017, 162 : 511 - 522
  • [24] Preparation of the Cf-GQDs-Escherichia coli O157: H7 Bioprobe and Its Application in Optical Imaging and Sensing of Escherichia coli O157: H7
    Yang, Xiaozhan
    Feng, Luqiao
    Qin, Xiang
    FOOD ANALYTICAL METHODS, 2018, 11 (08) : 2280 - 2286
  • [25] Carbon dots and covalent organic frameworks based FRET immunosensor for sensitive detection of Escherichia coli O157:H7
    Wang, Sunli
    Liang, Nini
    Hu, Xuetao
    Li, Wenting
    Guo, Ziang
    Zhang, Xinai
    Huang, Xiaowei
    Li, Zhihua
    Zou, Xiaobo
    Shi, Jiyong
    FOOD CHEMISTRY, 2024, 447
  • [26] A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7
    Su, XL
    Li, YB
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) : 563 - 574
  • [27] Immunoliposome sandwich assay for the detection of Escherichia coli O157:H7
    Park, S
    Durst, RA
    ANALYTICAL BIOCHEMISTRY, 2000, 280 (01) : 151 - 158
  • [28] Recent trends in the detection of pathogenic Escherichia coli O157 : H7
    Si-Ying Wu
    John Hulme
    Seong Soo A. An
    BioChip Journal, 2015, 9 : 173 - 181
  • [29] CdS quantum dots/Au nanoparticles/ZnO nanowire array for self-powered photoelectrochemical detection of Escherichia coli O157:H7
    Dong, Xiuxiu
    Shi, Zengliang
    Xu, Chunxiang
    Yang, Chi
    Chen, Feng
    Lei, Milan
    Wang, Junjie
    Cui, Qiannan
    BIOSENSORS & BIOELECTRONICS, 2020, 149
  • [30] A Label-Free Electrochemical Immunosensor Modified with AuNPs for Quantitative Detection of Escherichia coli O157:H7
    Huang, Yanyan
    Wu, Zunyi
    Zhao, Guangying
    Dou, Wenchao
    JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (12) : 7960 - 7969