Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water

被引:7
作者
Gan, Tingting [1 ,2 ]
Zhao, Nanjing [1 ,2 ]
Yin, Gaofang [1 ,2 ]
Chen, Min [1 ,2 ,3 ]
Wang, Xiang [1 ,2 ,3 ]
Hua, Hui [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Peoples R China
[2] Key Lab Opt Monitoring Technol Environm, Hefei 230031, Anhui, Peoples R China
[3] Univ Sci & Technol China, Hefei, Peoples R China
基金
中国国家自然科学基金;
关键词
cadmium; X-ray fluorescence; algae; preconcentration; rapid detection; SOLID-PHASE EXTRACTION; MULTIELEMENT DETERMINATION; CARBON NANOTUBES; GRAPHENE OXIDE; DRINKING-WATER; SAMPLES PRIOR; CADMIUM; PB; BIOSORPTION; REMOVAL;
D O I
10.1098/rsos.200182
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Freshwater green algae Chlorella vulgaris was selected as an adsorbent, and a simple, rapid, economical and environmentally friendly method for the detection of heavy metal Cd in water samples based on preconcentration with C. vulgaris combined with energy dispersive X-ray fluorescence (EDXRF) spectrometry was proposed. Chlorella vulgaris could directly and rapidly adsorb Cd2+ without any pretreatment, and the maximum adsorption efficiency could be obtained when the contact time was 1 min with an optimal pH of 10. The obtained Cd-enriched thin samples after preconcentration with C. vulgaris by suction filtration of reaction solution had very good uniformity, which could be directly measured by EDXRF spectrometry, and the net integral fluorescence intensity of Cd K alpha characteristic peak had a very good linear relationship with the initial concentration of Cd in the range of 0.703-74.957 mu g ml(-1) with a correlation coefficient of 0.9979. When the Cd thin samples with a Cd-enriched region of 15.1 mm in diameter were formed by the developed preconcentration method with suction filtration of 10 ml reaction solution, the detection limit of this method was 0.0654 mu g ml(-1), which was lower than the maximum allowable discharge concentration of Cd in various industrial wastewaters. The proposed method was simple to operate, and could effectively remove the influence of matrix effect of water samples and effectively improve the sensitivity and stability of EDXRF spectrometry directly detecting heavy metals in water samples, which was successfully applied to detect Cd in real water samples with satisfactory results, and the recoveries ranged from 94.80% to 116.94%. Moreover, this method can be applied to the rapid detection and early warning of excessive Cd in discharged industrial wastewaters. This work will provide a methodological basis for the development of rapid and online monitoring technology and instrument of heavy metal pollutants in water.
引用
收藏
页数:14
相关论文
共 34 条
[11]   An integrated system for field analysis of Cd(II) and Pb(II) via preconcentration using nano-TiO2/cellulose paper composite and subsequent detection with a portable X-ray fluorescence spectrometer [J].
Lin, Xiaofeng ;
Li, Shun-Xing ;
Zheng, Feng-Ying .
RSC ADVANCES, 2016, 6 (11) :9002-9006
[12]   High-energy polarized-beam energy-dispersive X-ray fluorescence analysis combined with activated thin layers for cadmium determination at trace levels in complex environmental liquid samples [J].
Margui, Eva ;
Fontas, Claudia ;
Van Meel, Katleen ;
Van Grieken, Ren ;
Queralt, Ignasi ;
Hidalgo, Manuela .
ANALYTICAL CHEMISTRY, 2008, 80 (07) :2357-2364
[13]   Improved instrumental sensitivity for Cd determination in aqueous solutions using Wavelength Dispersive X-ray Fluorescence Spectrometry, Rh-target tube instrumentation [J].
Margui, Eva ;
Fontas, Claudia ;
Hidalgo, Manuela ;
Queralt, Ignacio .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (11) :1329-1332
[14]   Determination of cadmium by an improved double chamber electrothermal vaporization inductively coupled plasma atomic emission spectrometry [J].
Matsumoto, Akihiro ;
Osaki, Shusuke ;
Kobata, Toshitsugu ;
Hashimoto, Bunji ;
Uchihara, Hiroshi ;
Nakahara, Taketoshi .
MICROCHEMICAL JOURNAL, 2010, 95 (01) :85-89
[15]   Combination of extraction induced by microemulsion-breaking and pre-concentration using magnetic nanoparticles for multi-element determination of Cd, Cr, Cu and Pb in gasoline samples using energy dispersive X-ray fluorescence spectrometry [J].
Meira, Lucilia A. ;
Almeida, Jorge S. ;
Dias, Fabio de S. ;
Teixeira, Leonardo S. G. .
MICROCHEMICAL JOURNAL, 2019, 147 :660-665
[16]   Multi-element determination of Cd, Pb, Cu, V, Cr, and Mn in ethanol fuel samples using energy dispersive X-ray fluorescence spectrometry after magnetic solid phase microextraction using CoFe2O4 nanoparticles [J].
Meira, Lucilia A. ;
Almeida, Jorge S. ;
Dias, Fabio de S. ;
Pedra, Pablo P. ;
Costa Pereira, Amalia L. ;
Teixeira, Leonardo S. G. .
MICROCHEMICAL JOURNAL, 2018, 142 :144-151
[17]   A simple method for monitoring of removal of arsenic species from drinking water applying on-site separation with solid phase extraction and detection by atomic absorption and X-ray fluorescence based techniques [J].
Mihucz, Victor G. ;
Enesei, Daniel ;
Veszely, Adam ;
Bencs, Laszlo ;
Pap-Balazs, Terez ;
Ovari, Mihaly ;
Streli, Christina ;
Zaray, Gyula .
MICROCHEMICAL JOURNAL, 2017, 135 :105-113
[18]   Integrated sorption-energy-dispersive X-ray fluorescence detection for automatic determination of lead and cadmium in low-concentration solutions [J].
Perez-Serradilla, J. A. ;
de Castro, M. D. Luque .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (05) :1541-1547
[19]   Graphene oxide covalently modified with 2,2′-iminodiacetic acid for preconcentration of Cr(III), Cu(II), Zn(II) and Pb(II) from water samples prior to their determination by energy dispersive X-ray fluorescence spectrometry [J].
Pytlakowska, Katarzyna ;
Matussek, Marek ;
Hachula, Barbara ;
Pilch, Michal ;
Kornaus, Kamil ;
Zubko, Maciej ;
Pisarski, Wojciech A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 147 :79-86
[20]   Glycine modified graphene oxide as a novel sorbent for preconcentration of chromium, copper, and zinc ions from water samples prior to energy dispersive X-ray fluorescence spectrometric determination [J].
Pytlakowska, Katarzyna ;
Kozik, Violetta ;
Matussek, Marek ;
Pilch, Michal ;
Hachula, Barbara ;
Kocot, Karina .