Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring

被引:181
作者
Zafar, Hima [1 ]
Channa, Asma [2 ,3 ]
Jeoti, Varun [1 ]
Stojanovic, Goran M. [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, T Dositeja Obradovica 6, Novi Sad 21000, Serbia
[2] Univ Politehn Bucuresti, Comp Sci Dept, Bucharest 060042, Romania
[3] Mediterranea Univ Reggio Calabria, DIIES Dept, I-89100 Reggio Di Calabria, Italy
关键词
biosensor; diabetes; hypoglycemia; sweat based sensing; wearable electronics; non-invasive glucose monitoring; BLOOD-GLUCOSE; ELECTROCHEMICAL SENSOR; TATTOO SENSOR; CARBON NANOTUBES; ELECTROLYTE; EXERCISE; NANOPARTICLES; CALIBRATION; BIOSENSORS; SYSTEM;
D O I
10.3390/s22020638
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered.
引用
收藏
页数:35
相关论文
共 159 条
[1]  
Abd Salam N.A.B., 2016, J. Telecommun. Electron. Comput. Eng, V8, P59
[2]   A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration [J].
Abellan-Llobregat, A. ;
Jeerapan, Itthipon ;
Bandodkar, A. ;
Vidal, L. ;
Canals, A. ;
Wang, J. ;
Morallon, E. .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :885-891
[3]   Determination of the maximum rate of eccrine sweat glands' ion reabsorption using the galvanic skin conductance to local sweat rate relationship [J].
Amano, Tatsuro ;
Gerrett, Nicola ;
Inoue, Yoshimitsu ;
Nishiyasu, Takeshi ;
Havenith, George ;
Kondo, Narihiko .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (02) :281-290
[4]   Smart Sensor Systems for Wearable Electronic Devices [J].
An, Byeong Wan ;
Shin, Jung Hwal ;
Kim, So-Yun ;
Kim, Joohee ;
Ji, Sangyoon ;
Park, Jihun ;
Lee, Youngjin ;
Jang, Jiuk ;
Park, Young-Geun ;
Cho, Eunjin ;
Jo, Subin ;
Park, Jang-Ung .
POLYMERS, 2017, 9 (08)
[5]   A wearable multisensing patch for continuous sweat monitoring [J].
Anastasova, Salzitsa ;
Crewther, Blair ;
Bembnowicz, Pawel ;
Curto, Vincenzo ;
Ip, Henry M. D. ;
Rosa, Bruno ;
Yang, Guang-Zhong .
BIOSENSORS & BIOELECTRONICS, 2017, 93 :139-145
[6]  
[Anonymous], 2016, Wearable Technology Market Analysis By Product (Wrist Wear, Eye-Wear, Foot-Wear, Neck-Wear, Body-Wear), By Application (Fitness Wellness, Healthcare, Infotainment, Defense, Enterprise And Industrial) And Segment Forecasts To 2022
[7]   IRON, COPPER AND ZINC CONCENTRATIONS IN HUMAN SWEAT AND PLASMA - THE EFFECT OF EXERCISE [J].
ARUOMA, OI ;
REILLY, T ;
MACLAREN, D ;
HALLIWELL, B .
CLINICA CHIMICA ACTA, 1988, 177 (01) :81-87
[8]  
BACtrack Skyn, BACTRACK SKYN WEAR A
[9]   Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: potential application to ophthalmic diagnostics [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
TALANTA, 2005, 65 (03) :762-768
[10]   Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring [J].
Bae, Chan Wool ;
Phan Tan Toi ;
Kim, Bo Yeong ;
Lee, Won Il ;
Lee, Han Byeol ;
Hanif, Adeela ;
Lee, Eung Hyuk ;
Lee, Nae-Eung .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (16) :14567-14575