LC-MS/MS assay for the quantitation of the ATR kinase inhibitor VX-970 in human plasma

被引:4
|
作者
Kiesel, Brian F. [1 ,2 ]
Scemama, Jonas [1 ,3 ]
Parise, Robert A. [1 ]
Villaruz, Liza [1 ,4 ]
Iffland, Andre [5 ]
Doyle, Austin [6 ]
Ivy, Percy [6 ]
Chu, Edward [1 ,4 ]
Bakkenist, Christopher J. [7 ,8 ]
Beumer, Jan H. [1 ,2 ,4 ]
机构
[1] Univ Pittsburgh, Inst Canc, Canc Therapeut Program, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Sch Pharm, Dept Pharmaceut Sci, Pittsburgh, PA 15213 USA
[3] Aix Marseille Univ, Fac Pharm, Pharmacokinet, Toxicokinet Dept, Marseille, France
[4] Univ Pittsburgh, Sch Med, Dept Med, Div Hematol Oncol, Pittsburgh, PA 15213 USA
[5] Vertex Pharmaceut, Preclin Safety Assessment Bioanal, Boston, MA USA
[6] NCI, Invest Drug Branch, Canc Therapy Evaluat Program, Div Canc Treatment & Diag, Bethesda, MD 20892 USA
[7] Univ Pittsburgh, Sch Med, Dept Radiat Oncol, Pittsburgh, PA 15213 USA
[8] Univ Pittsburgh, Sch Med, Dept Pharmacol & Chem Biol, Pittsburgh, PA 15213 USA
关键词
VX-970; Tandem mass spectrometry; Clinical; TANDEM MASS-SPECTROMETRY; DNA-DAMAGE RESPONSE; CANCER-CELLS; CHROMATOGRAPHY; GENE;
D O I
10.1016/j.jpba.2017.08.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
DNA damaging chemotherapy and radiation are widely used standard-of-care modalities for the treatment of cancer. Nevertheless, the outcome for many patients remains poor and this may be attributed, at least in part, to highly effective DNA repair mechanisms. Ataxia-telangiectasia mutated and Rad3-related (ATR) is a key regulator of the DNA-damage response (DDR) that orchestrates the repair of damaged replication forks. ATR is a serine/threonine protein kinase and ATR kinase inhibitors potentiate chemotherapy and radiation. The ATR kinase inhibitor VX-970 (NSC 780162) is in clinical development in combination with primary cytotoxic agents and as a monotherapy for tumors harboring specific mutations. We have developed and validated an LC-MS/MS assay for the sensitive, accurate and precise quantitation of VX-970 in human plasma. A dilute-and-shoot method was used to precipitate proteins followed by chromatographic separation with a Phenomenex Polar-RP 80 A (4 mu m, 50 x 2 mm) column and a gradient acetonitrile-water mobile phase containing 0.1% formic acid from a 50 L sample volume. Detection was achieved using an API 4000 mass spectrometer using electrospray positive ionization mode. The assay was linear from 3 to 5,000 ng/mL, proved to be accurate (94.6-104.2%) and precise (<8.4% CV), and fulfilled criteria from the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be a crucial tool in defining the clinical pharmacokinetics and pharmacology of VX-970 as it progresses through clinical development. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:244 / 250
页数:7
相关论文
共 50 条
  • [1] LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma
    Kiesel, Brian F.
    Parise, Robert A.
    Wong, Alvin
    Keyvanjah, Kiana
    Jacobs, Samuel
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 : 130 - 136
  • [2] LC-MS/MS assay for the quantitation of the ribonucleotide reductase inhibitor triapine in human plasma
    Matsumoto, Julia
    Kiesel, Brian F.
    Parise, Robert A.
    Guo, Jianxia
    Taylor, Sarah
    Huang, Marilyn
    Eiseman, Julie L.
    Ivy, S. Percy
    Kunos, Charles
    Chu, Edward
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 154 - 160
  • [3] LC-MS/MS assay for the quantitation of the HDAC inhibitor belinostat and five major metabolites in human plasma
    Kiesel, Brian F.
    Parise, Robert A.
    Tjornelund, Jette
    Christensen, Mette K.
    Loza, Einars
    Tawbi, Hussein
    Chu, Edward
    Kummar, Shivaani
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 81-82 : 89 - 98
  • [4] Sensitive and selective LC-MS/MS assay for quantitation of flutrimazole in human plasma
    Shen, L.
    Liu, S. -J.
    Zhang, N. -S.
    Dai, G. -L.
    Zou, C.
    Li, C. -Y.
    Chen, X. -H.
    Ju, W. -Z.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2017, 21 (12) : 2964 - 2969
  • [5] Quantitation of Cabozantinib in Human Plasma by LC-MS/MS
    Jones, Reyna
    Holleran, Julianne
    Parise, Robert A.
    Rudek, Michelle A.
    Chan, Jennifer
    Wen, Yujia
    Gobburu, Joga
    Lewis, Lionel D.
    Beumer, Jan H.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (03) : 274 - 279
  • [6] LC-MS/MS assay for the simultaneous quantitation of the ATM inhibitor AZ31 and the ATR inhibitor AZD6738 in mouse plasma
    Kiesel, Brian F.
    Shogan, Jeffrey C.
    Rachid, Madani
    Parise, Robert A.
    Vendetti, Frank P.
    Bakkenist, Christopher J.
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 138 : 158 - 165
  • [7] LC-MS/MS assay for the quantitation of FdCyd and its metabolites FdUrd and FU in human plasma
    Holleran, Julianne L.
    Eiseman, Julie L.
    Parise, Robert A.
    Kummar, Shivaani
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 129 : 359 - 366
  • [8] Rapid and sensitive LC-MS/MS assay for the quantitation of 20(S)-protopanaxadiol in human plasma
    Zhang, Dan
    Wang, Yingwu
    Han, Jiangbin
    Yu, Weisong
    Deng, Lili
    Fawcett, J. Paul
    Liu, Zeyuan
    Gu, Jingkai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 581 - 585
  • [9] Quantification of the janus kinase 1 inhibitor upadacitinib in human plasma by LC-MS/MS
    Martens-Lobenhoffer, Jens
    Tomaras, Stylianos
    Feist, Eugen
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1188
  • [10] Quantitation of melatonin and n-acetylserotonin in human plasma by nanoflow LC-MS/MS and electrospray LC-MS/MS
    Carter, Melissa D.
    Calcutt, M. Wade
    Malow, Beth A.
    Rose, Kristie L.
    Hachey, David L.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (03): : 277 - 285