Kinematic Alignment in Cruciate Retaining Implants Improves the Biomechanical Function in Total Knee Arthroplasty during Gait and Deep Knee Bend

被引:10
作者
Kang, Kyoung-Tak [1 ]
Koh, Yong-Gon [2 ]
Nam, Ji Hoon [2 ]
Kwon, Sae Kwang [2 ]
Park, Kwan Kyu [3 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul, South Korea
[2] Yonsei Sarang Hosp, Joint Reconstruct Ctr, Dept Orthopaed Surg, Seoul, South Korea
[3] Yonsei Univ, Dept Orthoped Surg, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
total knee arthroplasty; kinematic alignment; mechanical alignment; finite element analysis; ALIGNED TOTAL KNEE; POSTERIOR CONDYLAR; CONTACT STRESSES; JOINT; FLEXION; AXIS; MALALIGNMENT; COMPONENT; VARUS; SATISFACTION;
D O I
10.1055/s-0039-1677846
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Kinematic alignment (KA), which co-aligns the rotational axes of the components with three kinematic axes of the knee by aligning the components to the prearthritic joint lines, has been a recently introduced surgical technique. However, whether KA and cruciate retaining (CR) implants provide better biomechanical function during activities than mechanical alignment (MA) in posterior stabilized (PS) implants is unclear. We evaluated the biomechanical functions during the stance phase gait and deep knee bend, with a computer simulation and measured forces in the medial and lateral collateral ligaments and medial and lateral contact stresses in the polyethylene insert and patellar button. The forces on the medial collateral ligament in KA were lower than those in MA in both CR and PS TKA in the stance phase gait and deep knee bend conditions, whereas those on the lateral collateral ligament did not show any difference between the two surgical alignment techniques in the stance phase gait condition. The maximum contact stresses on the medial PE inserts in KA were lower than those in MA in both CR and PS TKA in the stance phase gait and deep knee bend conditions. However, the maximum contact stresses on the lateral PE inserts and the patellar button did not differ between MA and KA. The biomechanical function was superior in KA TKA than in MA TKA, and KA was more effective in CR TKA. This comparison could be used as a reference by surgeons to reduce the failure rates by using KA TKA instead of MA TKA.
引用
收藏
页码:284 / 293
页数:10
相关论文
共 49 条
  • [1] The role of pain and function in determining patient satisfaction after total knee replacement - Data from the National Joint Registry for England and Wales
    Baker, P. N.
    van der Meulen, J. H.
    Lewsey, J.
    Gregg, P. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (07): : 893 - 900
  • [2] Verification of predicted specimen-specific natural and implanted patellofemoral kinematics during simulated deep knee bend
    Baldwin, Mark A.
    Clary, Chadd
    Maletsky, Lorin P.
    Rullkoetter, Paul J.
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (14) : 2341 - 2348
  • [3] Component rotational alignment in unexplained painful primary total knee arthroplasty
    Bell, Stuart W.
    Young, Peter
    Drury, Colin
    Smith, Jules
    Anthony, Iain
    Jones, Bryn
    Blyth, Mark
    McLean, Angus
    [J]. KNEE, 2014, 21 (01) : 272 - 277
  • [4] Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset
    Bellemans, J
    Banks, S
    Victor, J
    Vandenneucker, H
    Moemans, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 50 - 53
  • [5] The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional Varus
    Bellemans, Johan
    Colyn, William
    Vandenneucker, Hilde
    Victor, Jan
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) : 45 - 53
  • [6] Validation of a three-dimensional model of the knee
    Blankevoort, L
    Huiskes, R
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (07) : 955 - 961
  • [7] Patient Satisfaction after Total Knee Arthroplasty Who is Satisfied and Who is Not?
    Bourne, Robert B.
    Chesworth, Bert M.
    Davis, Aileen M.
    Mahomed, Nizar N.
    Charron, Kory D. J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 57 - 63
  • [8] What are the bias, imprecision, and limits of agreement for finding the flexion-extension plane of the knee with five tibial reference lines?
    Brar, Abheetinder S.
    Howell, Stephen M.
    Hull, Maury L.
    [J]. KNEE, 2016, 23 (03) : 406 - 411
  • [9] Effect of Component Mal-Rotation on Knee Loading in Total Knee Arthroplasty Using Multi-Body Dynamics Modeling Under a Simulated Walking Gait
    Chen, Zhenxian
    Wang, Ling
    Liu, Yaxiong
    He, Jiankang
    Lian, Qin
    Li, Dichen
    Jin, Zhongmin
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (09) : 1287 - 1296
  • [10] Cherian JJ, 2014, CURR REV MUSCULOSKE, V7, P89, DOI 10.1007/s12178-014-9218-y