Platelet adhesion, contact phase coagulation activation, and C5a generation of polyethylene glycol acid-grafted high flux cellulosic membrane with varieties of grafting amounts

被引:25
作者
Fushimi, F [1 ]
Nakayama, M [1 ]
Nishimura, K [1 ]
Hiyoshi, T [1 ]
机构
[1] Asahi Chem Ind Co Ltd, Hollow Fiber Plant, Technol Dev Sect, Nobeoka, Miyazaki 882, Japan
关键词
biocompatibility; PEG acid-grafted high flux cellulosic membrane; platelet adhesion; contact phase of blood coagulation; complement activation;
D O I
10.1046/j.1525-1594.1998.06046.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Grafting of polyethylene glycol chains onto cellulosic membrane can be expected to reduce the interaction between blood (plasma protein and cells) and the membrane surface. Alkylether carboxylic acid (PEG acid) grafted high flux cellulosic membranes for hemodialysis, in which the polyethylene glycol chain bears an alkyl group at one side and a carboxyl group at the other side, have been developed and evaluated. PEG acid-grafted high flux cellulosic membranes with various grafting amounts have been compared with respect to platelet adhesion, the contact phase of blood coagulation, and complement activation in vitro. A new method of quantitating platelet adhesion on hollow-fiber membrane surfaces has been developed, which is based on the determination of lactate dehydrogenase (LDH) activity after lysis of the adhered platelets. PEG acid-grafted high flux cellulosic membranes showed reduced platelet adhesion and complement activation effects in grafting amounts of 200 ppm or higher without detecting adverse effects up to grafting amounts of 850 ppm. The platelet adhesion of a PEG acid-grafted cellulosic membrane depends on both the flux and grafting amounts of the membrane. It is concluded that the grafting of PEG acid onto a cellulosic membrane improves its biocompatibility as evaluated in terms of platelet adhesion, complement activation, and thrombogenicity.
引用
收藏
页码:821 / 826
页数:6
相关论文
共 20 条
[1]  
Akizawa T, 1989, ASAIO Trans, V35, P333
[2]  
AKIZAWA T, 1990, ASAIO T, V36, pM460
[3]  
CHENOWETH DE, 1984, ASAIO J, V7, P44
[4]   COMPLEMENT (C5A)-INDUCED GRANULOCYTE AGGREGATION INVITRO - POSSIBLE MECHANISM OF COMPLEMENT-MEDIATED LEUKOSTASIS AND LEUKOPENIA [J].
CRADDOCK, PR ;
HAMMERSCHMIDT, D ;
WHITE, JG ;
DALMASSO, AP ;
JACOB, HS .
JOURNAL OF CLINICAL INVESTIGATION, 1977, 60 (01) :260-264
[5]  
Deppisch R., 1992, Blood Purification, V10, P87
[6]   SOLUTION TECHNIQUE TO INCORPORATE POLYETHYLENE OXIDE AND OTHER WATER-SOLUBLE POLYMERS INTO SURFACES OF POLYMERIC BIOMATERIALS [J].
DESAI, NP ;
HUBBELL, JA .
BIOMATERIALS, 1991, 12 (02) :144-153
[7]   PREPARATION AND SURFACE CHARACTERIZATION OF PEO-GRAFTED AND HEPARIN-IMMOBILIZED POLYURETHANES [J].
HAN, DK ;
PARK, KD ;
AHN, KD ;
JEONG, SY ;
KIM, YH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A1) :87-104
[8]  
IKADA Y, 1984, ADV POLYM SCI, V57, P103
[9]   INTERACTIONS OF POLY(ETHYLENE GLYCOL)-GRAFTED CELLULOSE MEMBRANES WITH PROTEINS AND PLATELETS [J].
KISHIDA, A ;
MISHIMA, K ;
CORRETGE, E ;
KONISHI, H ;
IKADA, Y .
BIOMATERIALS, 1992, 13 (02) :113-118
[10]  
Klinkmann H, 1989, Contrib Nephrol, V70, P213