Temporary Percutaneous Mechanical Circulatory Support in Advanced Heart Failure

被引:15
作者
Brown, Jessica L. [1 ]
Estep, Jerry D. [2 ]
机构
[1] Houston Methodist Hosp, 6550 Fannin St,Suite 1901, Houston, TX 77030 USA
[2] Houston Methodist Hosp, Methodist DeBa Key Heart & Vasc Ctr, Houston Methodist Inst Acad Med, Heart Transplant & LVAD Program,Div Heart Failure, 6550 Fannin St,Suite 1901, Houston, TX 77030 USA
关键词
Cardiogenic shock; Percutaneous mechanical circulatory support; IABP; Impella; TandemHeart; ECMO; Pressure-volume loop; INTRAAORTIC BALLOON COUNTERPULSATION; VENTRICULAR ASSIST DEVICE; EXTRACORPOREAL MEMBRANE-OXYGENATION; RANDOMIZED CLINICAL-TRIAL; CARDIOGENIC-SHOCK; CORONARY INTERVENTION; GUIDELINES; SOCIETY; ECMO;
D O I
10.1016/j.hfc.2016.03.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiogenic shock is severe, refractory heart failure caused by significant myocardial dysfunction in the setting of adequate preload that is accompanied by systemic hypoperfusion. Progressive end-organ dysfunction is a hallmark of persistent cardiogenic shock and necessitates intervention to overcome altered hemodynamics and restore end-organ perfusion. Temporary percutaneous mechanical circulatory support is an established modality in the treatment of cardiogenic shock and is increasingly used in patients with cardiogenic shock as a bridge to recovery or further definitive therapy. This article reviews the current devices, their effects on left ventricular hemodynamics, and the evidence supporting their continued use.
引用
收藏
页码:385 / +
页数:15
相关论文
共 30 条
  • [1] Benefits of a novel percutaneous ventricular assist device for right heart failure: The prospective RECOVER RIGHT study of the Impel la RP device
    Anderson, Mark B.
    Goldstein, James
    Milano, Carmelo
    Morris, Lynn D.
    Kormos, Robert L.
    Bhama, Jay
    Kapur, Navin K.
    Barisal, Aditya
    Garcia, Jose
    Baker, Joshua N.
    Silvestry, Scott
    Holman, William L.
    Douglas, Pamela S.
    O'Neill, William
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12) : 1549 - 1560
  • [2] Bruckner BA, 2008, TEX HEART I J, V35, P447
  • [3] A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock
    Burkhoff, Daniel
    Cohen, Howard
    Brunckhorst, Corinna
    O'Neill, William W.
    [J]. AMERICAN HEART JOURNAL, 2006, 152 (03) : 469.e1 - 469.e8
  • [4] Hemodynamics of Mechanical Circulatory Support
    Burkhoff, Daniel
    Sayer, Gabriel
    Doshi, Darshan
    Uriel, Nir
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (23) : 2664 - 2674
  • [5] Impella ventricular support in clinical practice: Collaborative viewpoint from a European expert user group
    Burzotta, Francesco
    Trani, Carlo
    Doshi, Sagar N.
    Townend, Jonathan
    van Geuns, Robert Jan
    Hunziker, Patrick
    Schieffer, Bernhard
    Karatolios, Konstantinos
    Moller, Jacob Eifer
    Ribichini, Flavio L.
    Schaefer, Andreas
    Henriques, Jose P. S.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 : 684 - 691
  • [6] Complications of Extracorporeal Membrane Oxygenation for Treatment of Cardiogenic Shock and Cardiac Arrest: A Meta-Analysis of 1,866 Adult Patients
    Cheng, Richard
    Hachamovitch, Rory
    Kittleson, Michelle
    Patel, Jignesh
    Arabia, Francisco
    Moriguchi, Jaime
    Esmailian, Fardad
    Azarbal, Babak
    [J]. ANNALS OF THORACIC SURGERY, 2014, 97 (02) : 610 - 616
  • [7] Doll JA, 2015, CATHETER CARDIOVASC
  • [8] Percutaneous Placement of an Intra-Aortic Balloon Pump in the Left Axillary/Subclavian Position Provides Safe, Ambulatory Long-Term Support as Bridge to Heart Transplantation
    Estep, Jerry D.
    Cordero-Reyes, Andrea M.
    Bhimaraj, Arvind
    Trachtenberg, Barry
    Khalil, Nashwa
    Loebe, Matthias
    Bruckner, Brian
    Orrego, Carlos M.
    Bismuth, Jean
    Kleiman, Neal S.
    Torre-Amione, Guillermo
    [J]. JACC-HEART FAILURE, 2013, 1 (05) : 382 - 388
  • [9] The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summary
    Feldman, David
    Pamboukian, Salpy V.
    Teuteberg, Jeffrey J.
    Birks, Emma
    Lietz, Katherine
    Moore, Stephanie A.
    Morgan, Jeffrey A.
    Arabia, Francisco
    Bauman, Mary E.
    Buchholz, Hoger W.
    Deng, Mario
    Dickstein, Marc L.
    El-Banayosy, Aly
    Elliot, Tonya
    Goldstein, Daniel. J.
    Grady, Kathleen L.
    Jones, Kylie
    Hryniewicz, Katarzyna
    John, Ranjit
    Kaan, Annemarie
    Kusne, Shimon
    Loebe, Matthias
    Massicotte, M. Patricia
    Moazami, Nader
    Mohacsi, Paul
    Mooney, Martha
    Nelson, Thomas
    Pagani, Francis
    Perry, William
    Potapov, Evgenij V.
    Rame, Eduardo
    Russell, Stuart D.
    Sorensen, Erik N.
    Sun, Benjamin
    Strueber, Martin
    Mangi, Abeel A.
    Petty, Michael G.
    Rogers, Joseph
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (02) : 157 - 187
  • [10] The RECOVER I: A multicenter prospective study of Impella 5.0/LD for postcardiotomy circulatory support
    Griffith, Bartley P.
    Anderson, Mark B.
    Samuels, Louis E.
    Pae, Walter E., Jr.
    Naka, Yoshifumi
    Frazier, O. Howard
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (02) : 548 - 554