Effect of storage tanks on solar-powered absorption chiller cooling system performance

被引:5
作者
Toprak, Kasim [1 ]
Ouedraogo, Kiswendsida E. [2 ]
机构
[1] Izmir Inst Technol, Dept Mech Engn, TR-35430 Izmir, Turkey
[2] Izmir Inst Technol, Dept Energy Engn, Izmir, Turkey
关键词
absorption chiller; capacity factor; thermal storage; AIR-CONDITIONING SYSTEM; ENERGY-STORAGE; REDUCTION;
D O I
10.1002/er.5210
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermal storage, low power tariff at night, and low nocturnal temperature can be used in synergy to reduce the cooling costs of the solar-powered absorption chiller cooling systems. This study aims to reduce the required cooling capacity of an absorption chiller (ACH) powered by a solar parabolic trough collector (PTC) and a backup fuel boiler by integrating thermal storage tanks. The thermal performance of the system is simulated for a building that is cooled for 14 h/day. The system uses 1000 m(2) PTC with 1020 kW ACH. Chilled water storage (CHWS) and cooling water storage (CWS) effects on the system performance for different operation hours per day of the ACH under Izmir (Turkey) and Phoenix (USA) weather conditions are analyzed. When the ACH operates 14 h/day as the load for both systems and both locations, the variations of the solar collector efficiency and the cooling load to heat input ratio remain less than 4% after the modifications. From the addition of CHWS to the reference system, a parametric study consisting of changing the ACH operation hours per day shows that the required cooling capacity of the ACH can be reduced to 34%. The capacity factor of the ACH is improved from its reference value of 41% up to 96%.
引用
收藏
页码:4366 / 4375
页数:10
相关论文
共 31 条
[1]  
[Anonymous], 2017, RENEWABLE POWER GENE
[2]  
[Anonymous], 2005, EN EFF EL UT
[3]   Thermal conductivity of concrete - A review [J].
Asadi, Iman ;
Shafigh, Payam ;
Bin Abu Hassan, Zahiruddin Fitri ;
Mahyuddin, Norhayati Binti .
JOURNAL OF BUILDING ENGINEERING, 2018, 20 :81-93
[4]  
Ayhan Demirbas AAH & AAB, 2017, ENERGY SOURCES POL B, P12
[5]   Performance and sustainability assessment of energy options for building HVAC applications [J].
Balta, M. Tolga ;
Dincer, Ibrahim ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2010, 42 (08) :1320-1328
[6]   Evaluation of a novel solar driven sorption cooling/heating system integrated with PCM storage compartment [J].
Behi, Mohammadreza ;
Mirmohammadi, Seyed Aliakbar ;
Ghanbarpour, Morteza ;
Behi, Hamidreza ;
Palm, Bjorn .
ENERGY, 2018, 164 :449-464
[7]   The chilled water storage analysis for a university building cooling system [J].
Boonnasa, Somkiat ;
Namprakai, Pichai .
APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) :1396-1408
[8]  
CANBAY CS, 2003, OPT HVAC CONTR STRAT
[9]   Building energy-consumption status worldwide and the state-of-the-art technologies for zero-energy buildings during the past decade [J].
Cao, Xiaodong ;
Dai, Xilei ;
Liu, Junjie .
ENERGY AND BUILDINGS, 2016, 128 :198-213
[10]   Data-Driven Methodology for Energy and Peak Load Reduction of Residential HVAC Systems [J].
Cetin, Kristen Sara ;
Kallus, Catilyn .
ICSDEC 2016 - INTEGRATING DATA SCIENCE, CONSTRUCTION AND SUSTAINABILITY, 2016, 145 :852-859