Simultaneous Transapical Transcatheter Aortic Valve Replacement and Transcatheter Mitral Valve Replacement for Native Valvular Stenosis

被引:18
作者
Elkharbotly, Ali [1 ]
Delago, Augustin [1 ]
El-Hajjar, Mohammad [1 ]
机构
[1] Albany Med Coll, Div Cardiol, Med, Albany, NY 12208 USA
关键词
mitral valve disease; percutaneous intervention; percutaneous valve therapy; structural heart disease intervention; surgery; valvular; transcatheter valve implantation; aortic repair; endovascular; IMPLANTATION; 1ST;
D O I
10.1002/ccd.26078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve replacement (TAVR) is well established for patients who cannot undergo surgery (Leon et al., N Engl J Med 2010; 363: 1597) or are high risk for surgery (Smith et al., N Engl J Med 2011; 364: 2187-2198). Experience with the TAVR procedure has led to recent reports of successful transcatheter mitral valve replacement (TMVR) procedures (Cheung et al., J Am Coll Cardiol 2014; 64: 1814; Seiffert et al., J Am Coll Cardiol Interv 2012; 5: 341-349) separately or simultaneously with the TAVR. However, these reports were of simultaneous valve-in-valve procedures (Cheung Anson, et al. J Am Coll Cardiol 2013; 61: 1759-1766). A recent report from Portugal also reported simultaneous transpical implantation of an inverted transcatheter aortic valve-in-ring in the mitral position and transcatheter aortic valve (Hasan et al., Circulation 2013; 128: e74-e76). There has been an experience of TMVR only in native mitral valve for mitral valve stenosis, but none in both aortic and mitral valves. We report the first in human case of simultaneous transapical TAVR and TMVR in native valves secondary to valvular stenosis. Our patient was not a candidate for percutaneous balloon mitral valvuloplasty secondary to a high Wilkins Score. Sizing of the aortic valve was based on the transesophageal echocardiogram (TEE), whereas sizing of the mitral valve was based on TEE measurements and balloon inflation during left ventriculography. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1347 / 1351
页数:5
相关论文
共 50 条
[31]   Transapical Transcatheter Valve Replacement Using J-Valve for Aortic Valve Diseases [J].
Xue, Yunxing ;
Zhou, Qing ;
Li, Shuchun ;
Li, Jie ;
Mu, Dan ;
Luo, Xuan ;
Liu, Chang ;
Xu, Can ;
Wang, Dongjin .
ANNALS OF THORACIC SURGERY, 2021, 112 (04) :1243-1249
[32]   Transapical transcatheter aortic valve replacement in patients with cardiogenic shock [J].
D'Ancona, Giuseppe ;
Pasic, Miralem ;
Buz, Semih ;
Drews, Thorsten ;
Dreysse, Stephan ;
Kukucka, Marian ;
Hetzer, Roland ;
Unbehaun, Axel .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (04) :426-430
[33]   Modified transapical transcatheter aortic valve replacement: A new tailored approach to the aortic valve [J].
Mendoza, Cesar E. ;
Rivera, Hector .
JOURNAL OF CARDIAC SURGERY, 2022, 37 (06) :1642-1643
[34]   Reoperative transapical transcatheter aortic valve replacement for central aortic regurgitation [J].
Zhu, Yuanjia ;
Kapadia, Samir ;
Krishnaswamy, Amar ;
Svensson, Lars G. ;
Mick, Stephanie .
JOURNAL OF CARDIAC SURGERY, 2016, 31 (09) :572-574
[35]   Mitral valve regurgitation: a plea for transcatheter mitral valve replacement [J].
Modine, Thomas ;
Prendergast, Bernard ;
Piazza, Nicolo ;
Overtchouk, Pavel .
EUROINTERVENTION, 2019, 15 (07) :567-570
[36]   Transapical Mitral Valve Replacement for Mixed Native Mitral Stenosis and Regurgitation [J].
Bedzra, Edo ;
Don, Creighton W. ;
Reisman, Mark ;
Aldea, Gabriel S. .
ANNALS OF THORACIC SURGERY, 2016, 102 (02) :E97-E99
[37]   Impact of moderate to severe mitral stenosis in patients undergoing transcatheter aortic valve replacement [J].
Fischer, Quentin ;
Himbert, Dominique ;
Bernier, Mathieu ;
Urena, Marina ;
Nunes Ferreira-Neto, Alfredo ;
Paradis, Jean-Michel ;
Mohammadi, Siamak ;
Iung, Bernard ;
Rodes-Cabau, Josep .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 286 :36-42
[38]   Mitral regurgitation after transcatheter aortic valve replacement [J].
Nappi, Francesco ;
Nenna, Antonio ;
Timofeeva, Irina ;
Mihos, Christos ;
Gentile, Federico ;
Chello, Massimo .
JOURNAL OF THORACIC DISEASE, 2020, 12 (05) :2926-2935
[39]   Mitral Valve Stenosis after Transcatheter Aortic Valve Replacement: Case Report and Review of the Literature [J].
Cannata, Francesco ;
Regazzoli, Damiano ;
Barberis, Giancarlo ;
Chiarito, Mauro ;
Leone, Pier Pasquale ;
Lavanco, Vincenzo ;
Stefanini, Giulio G. ;
Ferrante, Giuseppe ;
Pagnotta, Paolo ;
Bragato, Renato ;
Corrada, Elena ;
Torracca, Lucia ;
Condorelli, Gianluigi ;
Reimers, Bernhard .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (12) :1196-1202
[40]   Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis [J].
Yoon, Sung-Han ;
Bleiziffer, Sabine ;
De Backer, Ole ;
Delgado, Victoria ;
Arai, Takahide ;
Ziegelmueller, Johannes ;
Barbanti, Marco ;
Sharma, Rahul ;
Perlman, Gidon Y. ;
Khalique, Omar K. ;
Holy, Erik W. ;
Saraf, Smriti ;
Deuschl, Florian ;
Fujita, Buntaro ;
Ruile, Philipp ;
Neumann, Franz-Josef ;
Pache, Gregor ;
Takahashi, Masao ;
Kaneko, Hidehiro ;
Schmidt, Tobias ;
Ohno, Yohei ;
Schofer, Niklas ;
Kong, William K. F. ;
Tay, Edgar ;
Sugiyama, Daisuke ;
Kawamori, Hiroyuki ;
Maeno, Yoshio ;
Abramowitz, Yigal ;
Chakravarty, Tarun ;
Nakamura, Mamoo ;
Kuwata, Shingo ;
Yong, Gerald ;
Kao, Hsien-Li ;
Lee, Michael ;
Kim, Hyo-Soo ;
Modine, Thomas ;
Wong, S. Chiu ;
Bedgoni, Francesco ;
Testa, Luca ;
Teiger, Emmanuel ;
Butter, Christian ;
Ensminger, Stephan M. ;
Schaefer, Ulrich ;
Dvir, Danny ;
Blanke, Philipp ;
Leipsic, Jonathon ;
Nietlispach, Fabian ;
Abdel-Wahab, Mohamed ;
Chevalier, Bernard ;
Tamburino, Corrado .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (21) :2579-2589