Respiratory Rate Extraction Via an Autoregressive Model Using the Optimal Parameter Search Criterion

被引:23
作者
Lee, J. [1 ]
Chon, K. H. [1 ]
机构
[1] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
关键词
Optimal parameter search; AR model; Respiratory rate; Pulse oximeter; Time-frequency spectrum; IDENTIFICATION; ALGORITHM;
D O I
10.1007/s10439-010-0080-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present an autoregressive model-based method which enables accurate respiratory rate extraction from pulse oximeter recordings over a wide range: 12-48 breaths/min. The method uses the optimal parameter search (OPS) technique to estimate accurate AR parameters which are then factorized into multiple pole terms. The pole with the highest magnitude is shown to correspond to the respiratory rate. The performance of the proposed method to extract respiratory rate is compared to the widely used Burg algorithm using both simulation examples and pulse oximeter recordings. In a previous study, we demonstrated several nonparametric time-frequency approaches that were more accurate than Burg's algorithm when the data length was 1 min [Chon, K. H., S. Dash, and K. Ju. IEEE Trans. Biomed. Eng. 56(8): 2054-2063, 2009]. One of the key advantages of the AR method is that a shorter data length can be used. Thus, in this study, we reduced the data length to 30 s and applied our OPS algorithm to examine if accurate respiratory rates can be extracted directly from pulse oximeter recordings. It was found that our proposed method's accuracy was consistently better with smaller variance than Burg's method. In particular, our proposed method's accuracy was significantly greater when respiratory rates were lower than 24 breaths/min.
引用
收藏
页码:3218 / 3225
页数:8
相关论文
共 14 条
[1]  
Ables J. G., 1974, Astronomy and Astrophysics Supplement Series, V15, P383
[2]  
Burg J. P., 1967, P 37 ANN INT SEG M O
[3]   Estimation of Respiratory Rate From Photoplethysmogram Data Using Time-Frequency Spectral Estimation [J].
Chon, Ki H. ;
Dash, Shishir ;
Ju, Kihwan .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (08) :2054-2063
[4]   Assessment of granger causality by nonlinear model identification: Application to short-term cardiovascular variability [J].
Faes, Luca ;
Nollo, Giandomenico ;
Chon, Ki H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (03) :381-395
[5]  
Fleming S.G., 2007, Int. J. Biol. Med. Sci., V2, P232
[6]  
Lu S, 2001, IEEE T BIO-MED ENG, V48, P1116
[7]  
Marple J.S. J., 1987, DIGITAL SPECTRAL ANA
[8]   The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform [J].
Shelley K.H. ;
Awad A.A. ;
Stout R.G. ;
Silverman D.G. .
J. Clin. Monit. Comput., 2006, 2 (81-87) :81-87
[9]   SOME CHARACTERISTICS OF A THYMIC HUMORAL FACTOR DETERMINED BY ASSAY IN VIVO OF DNA SYNTHESIS IN LYMPH NODES OF THYMECTOMIZED MICE [J].
TRAININ, N ;
BURGER, M ;
KAYE, AM .
BIOCHEMICAL PHARMACOLOGY, 1967, 16 (04) :711-&
[10]   A high resolution approach to estimating time-frequency spectra and their amplitudes [J].
Wang, HL ;
Siu, K ;
Ju, KW ;
Chon, KH .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (02) :326-338