3D contrast-enhanced MR angiography of the abdominal aorta and its distal branches: Interobserver agreement of radiologists in a routine examination

被引:11
作者
Billaud, Y
Beuf, O
Desjeux, G
Valette, PJ
Pilleul, F [1 ]
机构
[1] Hop Univ E Herriot, Dept Radiol Digest, Lyon, France
[2] Univ Lyon 1, Lab Resonance Magnet Nucl, CNRS, UMR 5012, F-69622 Villeurbanne, France
[3] Dept Epidemiol Med, Lyon, France
关键词
angiography; aorta; magnetic resonance; visceral arteries;
D O I
10.1016/j.acra.2004.10.060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate the quality of images of the aorta and visceral arteries made at a high level of spatial resolution with thin slices and an optimized acquisition time by three-dimensional contrast-enhanced magnetic resonance angiography (3D CE-MRA). Materials and Methods. 3D CE-MRA with a 1.4-mm slice thickness and 512-pixel base matrix was done on 62 consecutive patients with a 1.5-T magnetic resonance imaging MRI unit. A bolus test with a power injector was used to calculate the optimal scan delay time. For quantitative evaluation, the signal-to-noise ratio (SNR) was measured in 3 regions of interest. Qualitative image analysis was evaluated independently by two radiologists and graded on a scale of 0-3. Separate analyses were done for the aorta and distal visceral arterial branches. Results. The means SNR values were respectively 56.2 +/- 15.2 (mean +/- SD) for the aorta, 59.2 +/- 15.1 for the celiac trunk, and 57 +/- 15.2 for the superior mesenteric artery, with a homogeneous distribution (P = .99). Consistent enhancement was confirmed by the lack of statistically significant differences between the SNR values. The average score for vessel visualization on source images ranged from good to excellent for different segments. After post-processing of images, the average score for distal arterial segments was significantly improved. The overall agreement between the 2 reviewers in the visualization of definite artery segments was excellent (k = .91). Conclusion. 3D CE-MRA with a 512-pixel base matrix and thin slices can be applied in a reproducible way with excellent depiction and delineation of small vessels. Such a protocol could be used routinely.
引用
收藏
页码:155 / 163
页数:9
相关论文
共 34 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] Postprocessing techniques for gadolinium-enhanced three-dimensional MR angiography
    Davis, CP
    Hany, TF
    Wildermuth, S
    Schmidt, M
    Debatin, JF
    [J]. RADIOGRAPHICS, 1997, 17 (05) : 1061 - 1077
  • [3] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [4] Comparing contrast-enhanced breath-hold MR angiography and conventional angiography in the evaluation of mesenteric circulation
    Ernst, O
    Asnar, V
    Sergent, G
    Lederman, E
    Nicol, L
    Paris, JC
    L'Herminé, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) : 433 - 439
  • [5] High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography
    Fain, SB
    King, BF
    Breen, JF
    Kruger, DG
    Riederer, SJ
    [J]. RADIOLOGY, 2001, 218 (02) : 481 - 490
  • [6] Frayne R, 2000, J MAGN RESON IMAGING, V12, P476, DOI 10.1002/1522-2586(200009)12:3<476::AID-JMRI14>3.0.CO
  • [7] 2-F
  • [8] Optimization of contrast timing for breath-hold three-dimensional MR angiography
    Hany, TF
    McKinnon, GC
    Leung, DA
    Pfammatter, T
    Debatin, JF
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 551 - 556
  • [9] SURGICAL ANATOMY OF THE HEPATIC ARTERIES IN 1000 CASES
    HIATT, JR
    GABBAY, J
    BUSUTTIL, RW
    [J]. ANNALS OF SURGERY, 1994, 220 (01) : 50 - 52
  • [10] Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography
    Hilfiker, PR
    Herfkens, RJ
    Heiss, SG
    Alley, MT
    Fleischmann, D
    Pelc, NJ
    [J]. RADIOLOGY, 2000, 216 (01) : 298 - 303