Purpose: Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Testa for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Testa MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Materials and Methods: Between January 2005 and May 2010, 151 patients underwent radical prostatectomy. All patients were evaluated with either pelvic phased-array coil or endorectal coil prostate MRI prior to surgery (63 endorectal coils and 88 pelvic phased-array coils). Tumor stage based on MRI was compared with pathologic stage. We calculated the specificity, sensitivity and accuracy of each group in the evaluation of extracapsular extension and seminal vesicle invasion. Results: Both endorectal coil and pelvic phased-array coil MRI achieved high specificity, low sensitivity and moderate accuracy for the detection of extracapsular extension and seminal vesicle invasion. There were statistically no differences in specificity, sensitivity and accuracy between the two groups. Conclusion: Overall staging accuracy, sensitivity and specificity were not significantly different between endorectal coil and pelvic phased-array coil MRI.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [21] Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil
    O'Donohoe, Rory L.
    Dunne, Ruth M.
    Kimbrell, Vera
    Tempany, Clare M.
    ABDOMINAL RADIOLOGY, 2019, 44 (03) : 1062 - 1069
  • [22] Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil
    Rory L. O’Donohoe
    Ruth M. Dunne
    Vera Kimbrell
    Clare M. Tempany
    Abdominal Radiology, 2019, 44 : 1062 - 1069
  • [23] Accuracy of 3-Tesla Magnetic Resonance Imaging for the Staging of Prostate Cancer in Comparison to the Partin Tables
    Augustin, H.
    Fritz, G. A.
    Ehammer, T.
    Auprich, M.
    Pummer, K.
    ACTA RADIOLOGICA, 2009, 50 (05) : 562 - 569
  • [24] 3-T MRI with phased-array surface coil in the local staging of rectal cancer
    Sani, F.
    Foresti, M.
    Parmiggiani, A.
    D'Andrea, V.
    Manenti, A.
    Amorotti, C.
    Scotti, R.
    Gallo, E.
    Torricelli, P.
    RADIOLOGIA MEDICA, 2011, 116 (03): : 375 - 388
  • [25] The Predictive Value of Endorectal 3 Tesla Multiparametric Magnetic Resonance Imaging for Extraprostatic Extension in Patients with Low, Intermediate and High Risk Prostate Cancer
    Somford, D. M.
    Hamoen, E. H.
    Futterer, J. J.
    van Basten, J. P.
    Hulsbergen-van de Kaa, C. A.
    Vreuls, W.
    van Oort, I. M.
    Vergunst, H.
    Kiemeney, L. A.
    Barentsz, J. O.
    Witjes, J. A.
    JOURNAL OF UROLOGY, 2013, 190 (05) : 1728 - 1734
  • [26] PRELIMINARY-RESULTS OF ENDORECTAL SURFACE COIL MAGNETIC-RESONANCE-IMAGING FOR LOCAL STAGING OF PROSTATE-CANCER
    JAGER, GJ
    BARENTSZ, JO
    DELAROSETTE, JJMCH
    ROSENBUSCH, G
    RADIOLOGE, 1994, 34 (03): : 129 - 133
  • [27] Role of endorectal magnetic resonance imaging and transrectal ultrasonography in the local staging of prostate cancer
    May, F
    Treumann, T
    Dettmar, P
    Hartung, R
    Breul, J
    UROLOGE A, 2002, 41 (05): : 458 - +
  • [28] Combined endorectal and phased-array MRI in the prediction of pelvic lymph node metastasis in prostate cancer
    Wang, L
    Hricak, H
    Kattan, MW
    Schwartz, LH
    Eberhardt, SC
    Chen, HN
    Scardino, PT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 743 - 748
  • [29] Gadolinium-enhanced dynamic magnetic resonance imaging with endorectal coil for local staging of rectal cancer
    Tamakawa, Mitsuharu
    Kawaai, Yuriko
    Shirase, Ryuji
    Satoh, Taishi
    Akiba, Hidenari
    Hyodoh, Hideki
    Hareyama, Masato
    Furuhata, Tomohisa
    Hirata, Koichi
    Hasegawa, Tadashi
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (04): : 290 - 298
  • [30] Prostate MR imaging at 3T with a longitudinal array endorectal surface coil and phased array body coil
    Kim, David Y.
    Schnall, Mitchell D.
    Rosen, Mark A.
    Connick, Thomas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1327 - 1330