Pulmonary ultrasound and pulse oximetry versus chest radiography and arterial blood gas analysis for the diagnosis of acute respiratory distress syndrome: a pilot study

被引:43
作者
Bass, Cameron M. [1 ,2 ]
Sajed, Dana R. [1 ,2 ]
Adedipe, Adeyinka A. [1 ]
West, T. Eoin [1 ,2 ]
机构
[1] Univ Washington, Sch Med, Dept Med, Seattle, WA 98195 USA
[2] Univ Washington, Sch Med, Int Resp & Severe Illness Ctr, Seattle, WA 98195 USA
来源
CRITICAL CARE | 2015年 / 19卷
关键词
LUNG ULTRASOUND; CRITICAL-CARE; RATIO;
D O I
10.1186/s13054-015-0995-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: In low-resource settings it is not always possible to acquire the information required to diagnose acute respiratory distress syndrome (ARDS). Ultrasound and pulse oximetry, however, may be available in these settings. This study was designed to test whether pulmonary ultrasound and pulse oximetry could be used in place of traditional radiographic and oxygenation evaluation for ARDS. Methods: This study was a prospective, single-center study in the ICU of Harborview Medical Center, a referral hospital in Seattle, Washington, USA. Bedside pulmonary ultrasound was performed on ICU patients receiving invasive mechanical ventilation. Pulse oximetric oxygen saturation (SpO(2)), partial pressure of oxygen (PaO2), fraction of inspired oxygen (FiO(2)), provider diagnoses, and chest radiograph closest to time of ultrasound were recorded or interpreted. Results: One hundred and twenty three ultrasound assessments were performed on 77 consecutively enrolled patients with respiratory failure. Oxygenation and radiographic criteria for ARDS were met in 35 assessments. Where SpO(2) <= 97 %, the Spearman rank correlation coefficient between SpO(2)/FiO(2) and PaO2/FiO(2) was 0.83, p < 0.0001. The sensitivity and specificity of the previously reported threshold of SpO(2)/FiO(2) <= 315 for PaO2/FiO(2) <= 300 was 83 % (95 % confidence interval (CI) 68-93), and 50 % (95 % CI 1-99), respectively. Sensitivity and specificity of SpO(2)/FiO(2) <= 235 for PaO2/FiO(2) <= 200 was 70 % (95 % CI 47-87), and 90 % (95 % CI 68-99), respectively. For pulmonary ultrasound assessments interpreted by the study physician, the sensitivity and specificity of ultrasound interstitial syndrome bilaterally and involving at least three lung fields were 80 % (95 % CI 63-92) and 62 % (95 % CI 49-74) for radiographic criteria for ARDS. Combining SpO(2)/FiO(2) with ultrasound to determine oxygenation and radiographic criteria for ARDS, the sensitivity was 83 % (95 % CI 52-98) and specificity was 62 % (95 % CI 38-82). For moderate-severe ARDS criteria (PaO2/FiO(2) <= 200), sensitivity was 64 % (95 % CI 31-89) and specificity was 86 % (95 % CI 65-97). Excluding repeat assessments and independent interpretation of ultrasound images did not significantly alter the sensitivity measures. Conclusions: Pulse oximetry and pulmonary ultrasound may be useful tools to screen for, or rule out, impaired oxygenation or lung abnormalities consistent with ARDS in under-resourced settings where arterial blood gas testing and chest radiography are not readily available.
引用
收藏
页数:11
相关论文
共 27 条
[1]   Critical Care 1 Critical care and the global burden of critical illness in adults [J].
Adhikari, Neill K. J. ;
Fowler, Robert A. ;
Bhagwanjee, Satish ;
Rubenfeld, Gordon D. .
LANCET, 2010, 376 (9749) :1339-1346
[2]   Is thoracic ultrasound a viable alternative to conventional imaging in the critical care setting? [J].
Ashton-Cleary, D. T. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) :152-160
[3]  
Baker Kylie, 2013, Australas J Ultrasound Med, V16, P86, DOI 10.1002/j.2205-0140.2013.tb00170.x
[4]   Evaluation of ultrasound lung comets by hand-held echocardiography [J].
Bedetti G. ;
Gargani L. ;
Corbisiero A. ;
Frassi F. ;
Poggianti E. ;
Mottola G. .
Cardiovascular Ultrasound, 4 (1)
[5]   THE AMERICAN-EUROPEAN CONSENSUS CONFERENCE ON ARDS - DEFINITIONS, MECHANISMS, RELEVANT OUTCOMES, AND CLINICAL-TRIAL COORDINATION [J].
BERNARD, GR ;
ARTIGAS, A ;
BRIGHAM, KL ;
CARLET, J ;
FALKE, K ;
HUDSON, L ;
LAMY, M ;
LEGALL, JR ;
MORRIS, A ;
SPRAGG, R ;
COCHIN, B ;
LANKEN, PN ;
LEEPER, KV ;
MARINI, J ;
MURRAY, JF ;
OPPENHEIMER, L ;
PESENTI, A ;
REID, L ;
RINALDO, J ;
VILLAR, J ;
VANASBECK, BS ;
DHAINAUT, JF ;
MANCEBO, J ;
MATTHAY, M ;
MEYRICK, B ;
PAYEN, D ;
PERRET, C ;
FOWLER, AA ;
SCHALLER, MD ;
HUDSON, LD ;
HYERS, T ;
KNAUS, W ;
MATTHAY, R ;
PINSKY, M ;
BONE, RC ;
BOSKEN, C ;
JOHANSON, WG ;
LEWANDOWSKI, K ;
REPINE, J ;
RODRIGUEZROISIN, R ;
ROUSSOS, C ;
ANTONELLI, MA ;
BELOUCIF, S ;
BIHARI, D ;
BURCHARDI, H ;
LEMAIRE, F ;
MONTRAVERS, P ;
PETTY, TL ;
ROBOTHAM, J ;
ZAPOL, W .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (03) :818-824
[6]  
Biddison LD, 2014, CHEST J, V146
[7]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308
[8]   Chest sonography: a useful tool to differentiate acute cardiogenic pulmonary edema from acute respiratory distress syndrome [J].
Copetti, Roberto ;
Soldati, Gino ;
Copetti, Paolo .
CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)
[9]   A review and analysis of intensive care medicine in the least developed countries [J].
Dünser, MW ;
Baelani, I ;
Ganbold, L .
CRITICAL CARE MEDICINE, 2006, 34 (04) :1234-1242
[10]  
Einav S, 2014, CHEST, V146