Quantitative Analysis of Lorazepam in Pharmaceutical Formulation Through FTIR Spectroscopy

被引:11
作者
Konoz, Elaheh [1 ]
Sarrafi, Amir Hossein Mohsen [1 ]
Samadizadeh, Marjaneh [1 ]
Boreiri, Samaneh [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Fac Sci, Cent Tehran Branch, Tehran, Iran
关键词
FTIR; lorazepam; Tablets; Pharmaceuticals; Determination; PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; INFRARED DETERMINATION; DIRECT-INJECTION; BENZODIAZEPINES; DIAZEPAM; COLUMN; PLASMA; URINE;
D O I
10.1155/2012/914974
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A Fourier transform infrared (FTIR) spectrophotometric method was development for the rapid, direct measurement of lorazepam in different pharmaceutical products. The method involves the off-line extraction of lorazepam with sonication and direct determination in the extract through peak height measurement in the 1704 cm(-1) using a baseline correction between 1850 and 1550 cm(-1). For standardization an external calibration line established from standard solutions of lorazepam in chloroform were used. The method provides a limit of detection of 0.0030 mg per tablet (n=5), a relative standard deviation (RSD) of 2.65% for 5 independent measurement of standard solution at a concentration level of 1 mgg(-1). Result obtained by FTIR agrees with those obtained by a reference methodology based on ultraviolet spectrometry and thus the developed procedure offers a good alternative for the determination of lorazepam in commercial products.
引用
收藏
页码:2232 / 2238
页数:7
相关论文
共 12 条
[1]   Simultaneous determination of fifteen low-dosed benzodiazepines in human urine by solid-phase extraction and gas chromatography-mass spectrometry [J].
Borrey, D ;
Meyer, E ;
Lambert, W ;
Van Peteghem, C ;
De Leenheer, AP .
JOURNAL OF CHROMATOGRAPHY B, 2001, 765 (02) :187-197
[2]   Sensitive gas chromatographic-mass spectrometric screening of acetylated benzodiazepines [J].
Borrey, D ;
Meyer, E ;
Lambert, W ;
Van Calenbergh, S ;
Van Peteghem, C ;
De Leenheer, AP .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :105-118
[3]   Rapid analysis of benzodiazepines in whole blood by high-performance liquid chromatography: use of a monolithic column [J].
Bugey, A ;
Staub, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (03) :555-562
[4]  
DEJULIANORTIZ JV, 1990, CAN J SPECTROSC, V35, P44
[5]  
GHOSH J, 2003, TXB PHARM CHEM
[6]   Simple method for the determination of benzodiazepines in human body fluids by high-performance liquid chromatography-mass spectrometry [J].
Lee, XP ;
Kumazawa, T ;
Sato, J ;
Shoji, Y ;
Hasegawa, C ;
Karibe, C ;
Arinobu, T ;
Seno, H ;
Sato, K .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :223-231
[7]  
Lin-Vein D., 1991, INFRARED RAMAN CHARA
[8]   Voltammetric analysis of lipophilicity of benzodiazepine derivatives at the water | 1,2-dichloroethane interface [J].
Monzón, LMA ;
Yudi, LM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 495 (02) :146-151
[9]   Quality control Fourier transform infrared determination of diazepam in pharmaceuticals [J].
Moros, Javier ;
Garrigues, Salvador ;
de la Guardia, Miguel .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) :1277-1282
[10]   Determination of lormetazepam and its main metabolite in serum using micellar electrokinetic capillary chromatography with direct injection and ultraviolet absorbance detection [J].
Nevado, JJB ;
Peñalvo, GC ;
Calderón, MJP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02) :151-158