Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality

被引:61
作者
Tonning, E
Sapelnikova, S
Christensen, J
Carlsson, C
Winther-Nielsen, M
Dock, E
Solna, R
Skladal, P
Norgaard, L
Ruzgas, T
Emnéus, J
机构
[1] Lund Univ, Dept Analyt Chem, Ctr Chem & Chem Engn, S-22100 Lund, Sweden
[2] Royal Vet & Agr Univ, Ctr Adv Food Studies, Chemometr Grp, Dept Food Sci, DK-1958 Frederiksberg, Denmark
[3] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
[4] ANOX AB, S-22647 Lund, Sweden
[5] Danish Hydraul Inst, Water & Environm, Dept Environm Risk Assessment, DK-2970 Horsholm, Denmark
[6] Masaryk Univ, Dept Biochem, Fac Sci, CS-61137 Brno, Czech Republic
关键词
wastewater; pattern recognition; principal component analysis; multiplicative drift correction; bioelectronic tongue; amperometric sensor array;
D O I
10.1016/j.bios.2004.12.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Four wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chen-ti-thermo-mechanical pulp mill and pure water were investigated using an amperometric bioelectronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase. At a constant potential the current intensity on each sensor was measured for 200s, 100s before injection and 100s after injection of the sample. The dynamic biosensor response curves from the eight sensors were used for principal component analysis (PCA). A simple baseline and sensitivity correction equivalent to multiplicative drift correction (MDC), using steady state intensities of reference sample (catechol) recordings, was employed. A clear pattern emerged in perfect agreement with prior knowledge of the samples explaining 97% of the variation in the data by two principal components (PCs). The first PC described the treatment quality of the samples and the second PC described the difference between treated and untreated samples. Horseradish peroxidase and pure platinum sensors were found to be the determinant sensors, while the rest did not contribute much to the discrimination. The wastewater samples were characterized by the chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), inhibition of nitrification, inhibition of respiration and toxicity towards Vibrio fischeri using Microtox (R), the freshwater alga Pseudokirchneriella subcapita and the freshwater crustacean Daphnia magna. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:608 / 617
页数:10
相关论文
共 24 条
[1]   Aquatic toxicity from pulp and paper mill effluents: a review [J].
Ali, M ;
Sreekrishnan, TR .
ADVANCES IN ENVIRONMENTAL RESEARCH, 2001, 5 (02) :175-196
[2]  
Artursson T, 2000, J CHEMOMETR, V14, P711, DOI 10.1002/1099-128X(200009/12)14:5/6<711::AID-CEM607>3.3.CO
[3]  
2-W
[4]   An electronic nose for the discrimination of forane 134a and carbon dioxide in a humidity controlled atmosphere [J].
Delpha, C ;
Siadat, M ;
Lumbreras, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :49-56
[5]   Multivariate data analysis of dynamic amperometric biosensor responses from binary analyte mixtures -: application of sensitivity correction algorithms [J].
Dock, E ;
Christensen, J ;
Olsson, M ;
Tonning, E ;
Ruzgas, T ;
Emnéus, J .
TALANTA, 2005, 65 (02) :298-305
[6]  
DOCK E, 2004, IN PRESS ANAL CHIM A
[7]   Orthogonal signal correction, wavelet analysis, and multivariate calibration of complicated process fluorescence data [J].
Eriksson, L ;
Trygg, J ;
Johansson, E ;
Bro, R ;
Wold, S .
ANALYTICA CHIMICA ACTA, 2000, 420 (02) :181-195
[8]   A calibration method for handling the temporal drift of solid state gas-sensors [J].
Haugen, JE ;
Tomic, O ;
Kvaal, K .
ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) :23-39
[9]   Drift counteraction for an electronic nose [J].
Holmberg, M ;
Winquist, F ;
Lundstrom, I ;
Davide, F ;
DiNatale, C ;
DAmico, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 36 (1-3) :528-535
[10]   Drift counteraction in odour recognition applications: lifelong calibration method [J].
Holmberg, M ;
Davide, FAM ;
DiNatale, C ;
DAmico, A ;
Winquist, F ;
Lundstrom, I .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 42 (03) :185-194