Identification of the Most Accurate Spectral-domain Optical Coherence Tomography Parameters in Eyes With Early High-Tension and Low-Tension Glaucoma

被引:2
作者
Gracitelli, Carolina P. B. [1 ,3 ]
Moreno, Pilar A. [1 ,2 ]
Leite, Mauro T. [1 ]
Prata, Tiago S. [1 ,2 ]
机构
[1] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[2] Hosp Oftalmol Med Olhos, Osasco, Brazil
[3] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, 9500 Gilman Dr, La Jolla, CA 92093 USA
关键词
spectral-domain optical coherence tomography; ganglion cells; nerve fiber layer; NERVE-FIBER LAYER; GANGLION-CELL COMPLEX; VISUAL-FIELD SENSITIVITY; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; FOURIER-DOMAIN; THICKNESS; DIAGNOSIS; DAMAGE; OCT;
D O I
10.1097/IJG.0000000000000406
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of the study was to compare the diagnostic ability of macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) thickness in high-tension glaucoma (HTG) and low-tension glaucoma (LTG). Patients and Methods: Glaucoma was defined as glaucomatous optic neuropathy and reproducible visual field defects. Patients were classified as having LTG if untreated intraocular pressure was <= 21mm Hg on 2 different occasions. Only eyes with early glaucoma (mean deviation < -6 dB) were included. All patients underwent spectral-domain optical coherence tomography (SDOCT) imaging. Results: A total of 56 normal subjects, 64 HTG patients, and 35 LTG patients were enrolled. Overall, after adjusting for mean deviation and age, the average pRNFL thickness in eyes with LTG was 18.7 mm thinner than in eyes with HTG (17% difference, P < 0.01). In the HTG group, no significant difference was found between areas under the receiver operating characteristic curve (AUCs) for average GCC and average pRNFL thicknesses (0.77 vs. 0.68, P = 0.06). In the LTG group, average pRNFL thickness had a significantly larger AUC compared with average GCC thickness (0.95 vs. 0.81, P < 0.001). Comparing AUCs between HTG and LTG groups, although the average GCC had similar AUCs in both groups (P = 0.47), the average pRNFL thickness had a significantly larger AUC in the LTG group (P < 0.001). Conclusions: In eyes with early glaucoma, the pRNFL thickness scan seems to be a more accurate SDOCT protocol to identify those with LTG compared with the GCC thickness scan.
引用
收藏
页码:854 / 859
页数:6
相关论文
共 54 条
  • [11] Results of the European Glaucoma Prevention Study
    Centofanti, M
    Zeyen, T
    Miglior, S
    [J]. OPHTHALMOLOGY, 2005, 112 (03) : 366 - 375
  • [12] Relationship between Visual Field Sensitivity and Macular Ganglion Cell Complex Thickness as Measured by Spectral-Domain Optical Coherence Tomography
    Cho, Jung Woo
    Sung, Kyung Rim
    Lee, Suhwan
    Yun, Sung-Cheol
    Kang, Sung Yong
    Choi, Jaewan
    Na, Jung Hwa
    Lee, Youngrok
    Kook, Michael S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6401 - 6407
  • [13] TOPOGRAPHY OF GANGLION-CELLS IN HUMAN RETINA
    CURCIO, CA
    ALLEN, KA
    [J]. JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 300 (01) : 5 - 25
  • [14] Mapping the visual field to the optic disc in normal tension glaucoma eyes
    Garway-Heath, DF
    Poinoosawmy, D
    Fitzke, FW
    Hitchings, RA
    [J]. OPHTHALMOLOGY, 2000, 107 (10) : 1809 - 1815
  • [15] Gracitelli CP, 2014, OPEN OPHTHALMOL J, V9, P68
  • [16] Greenfield DS, 2003, ARCH OPHTHALMOL-CHIC, V121, P41
  • [17] Diagnosis of glaucoma and detection of glaucoma progression using spectral domain optical coherence tomography
    Grewal, Dilraj S.
    Tanna, Angelo P.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (02) : 150 - 161
  • [18] Epidemiology 2 - Compared to what? Finding controls for case-control studies
    Grimes, DA
    Schulz, KF
    [J]. LANCET, 2005, 365 (9468) : 1429 - 1433
  • [19] Age-related losses of retinal ganglion cells and axons
    Harwerth, Ronald S.
    Wheat, Joe L.
    Rangaswamy, Nalini V.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) : 4437 - 4443
  • [20] Modeling the effects of aging on retinal ganglion cell density and nerve fiber layer thickness
    Harwerth, Ronald S.
    Wheat, Joe L.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (02) : 305 - 314