Identification of the Most Accurate Spectral-domain Optical Coherence Tomography Parameters in Eyes With Early High-Tension and Low-Tension Glaucoma

被引:2
作者
Gracitelli, Carolina P. B. [1 ,3 ]
Moreno, Pilar A. [1 ,2 ]
Leite, Mauro T. [1 ]
Prata, Tiago S. [1 ,2 ]
机构
[1] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[2] Hosp Oftalmol Med Olhos, Osasco, Brazil
[3] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, 9500 Gilman Dr, La Jolla, CA 92093 USA
关键词
spectral-domain optical coherence tomography; ganglion cells; nerve fiber layer; NERVE-FIBER LAYER; GANGLION-CELL COMPLEX; VISUAL-FIELD SENSITIVITY; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; FOURIER-DOMAIN; THICKNESS; DIAGNOSIS; DAMAGE; OCT;
D O I
10.1097/IJG.0000000000000406
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of the study was to compare the diagnostic ability of macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) thickness in high-tension glaucoma (HTG) and low-tension glaucoma (LTG). Patients and Methods: Glaucoma was defined as glaucomatous optic neuropathy and reproducible visual field defects. Patients were classified as having LTG if untreated intraocular pressure was <= 21mm Hg on 2 different occasions. Only eyes with early glaucoma (mean deviation < -6 dB) were included. All patients underwent spectral-domain optical coherence tomography (SDOCT) imaging. Results: A total of 56 normal subjects, 64 HTG patients, and 35 LTG patients were enrolled. Overall, after adjusting for mean deviation and age, the average pRNFL thickness in eyes with LTG was 18.7 mm thinner than in eyes with HTG (17% difference, P < 0.01). In the HTG group, no significant difference was found between areas under the receiver operating characteristic curve (AUCs) for average GCC and average pRNFL thicknesses (0.77 vs. 0.68, P = 0.06). In the LTG group, average pRNFL thickness had a significantly larger AUC compared with average GCC thickness (0.95 vs. 0.81, P < 0.001). Comparing AUCs between HTG and LTG groups, although the average GCC had similar AUCs in both groups (P = 0.47), the average pRNFL thickness had a significantly larger AUC in the LTG group (P < 0.001). Conclusions: In eyes with early glaucoma, the pRNFL thickness scan seems to be a more accurate SDOCT protocol to identify those with LTG compared with the GCC thickness scan.
引用
收藏
页码:854 / 859
页数:6
相关论文
共 54 条
  • [1] Abe RY, 2014, OPEN OPHTHALMOL J, V9, P78
  • [2] RATE AND PATTERN OF NEURORETINAL RIM AREA DECREASE IN OCULAR HYPERTENSION AND GLAUCOMA
    AIRAKSINEN, PJ
    TUULONEN, A
    ALANKO, HI
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (02) : 206 - 210
  • [3] Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by optical coherence tomography
    Ajtony, Csilla
    Balla, Zsolt
    Somoskeoy, Szabolcs
    Kovacs, Balint
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) : 258 - 263
  • [4] Distribution-free ROC analysis using binary regression techniques
    Alonzo, TA
    Pepe, MS
    [J]. BIOSTATISTICS, 2002, 3 (03) : 421 - 432
  • [5] Alward WL, 1998, AM J OPHTHALMOL, V126, P498
  • [6] Alward WLM, 2001, OPHTHALMOLOGY, V108, P247
  • [7] ARAIE M, 1993, OPHTHALMOLOGY, V100, P1808
  • [8] The Applicability of Ganglion Cell Complex Parameters Determined From SD-OCT Images to Detect Glaucomatous Eyes
    Arintawati, Paramastri
    Sone, Takashi
    Akita, Tomoyuki
    Tanaka, Junko
    Kiuchi, Yoshiaki
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (09) : 713 - 718
  • [9] Correlation among retinal thickness, optic disc, and visual field in glaucoma patients and suspects: A pilot study
    Asrani, S
    Challa, P
    Herndon, L
    Lee, P
    Stinnett, S
    Allingham, RR
    [J]. JOURNAL OF GLAUCOMA, 2003, 12 (02) : 119 - 128
  • [10] COMPARISON OF VISUAL-FIELD DEFECTS IN THE LOW-TENSION GLAUCOMAS WITH THOSE IN THE HIGH-TENSION GLAUCOMAS
    CAPRIOLI, J
    SPAETH, GL
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 97 (06) : 730 - 737