Applications of the infrared thermography in the energy audit of buildings: A review

被引:168
|
作者
Lucchi, Elena [1 ,2 ]
机构
[1] Politecn Milan, Via Bonardi 9, I-20133 Milan, Italy
[2] EURAC Res, Viale Druso 1, I-39100 Bolzano, Italy
来源
关键词
Infrared thermography; Building energy audit; Energy loss; air leakage; thermal bridging; moisture; THERMAL-DIFFUSIVITY MEASUREMENTS; NONDESTRUCTIVE EVALUATION; PULSED THERMOGRAPHY; DEFECT DETECTION; IR THERMOGRAPHY; AIR TIGHTNESS; HEAT-LOSS; U-VALUE; BRIDGES; VALIDATION;
D O I
10.1016/j.rser.2017.10.031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
From a wide range of bibliography (148 publications composed by books, guidelines, scientific papers, and other documents), the study presents a critical review of the use of the infrared thermography (IRT) survey in the building energy audit. After explaining its historical growth, the applicability of passive and active approaches has been described, considering well-established and emerging techniques, general procedures, types of IR-camera used, technical issues, and limitations. The passive approach is the most common to detect thermally significant defects. Thus, a specific procedure for the energy audit has been reported, matching different standards, guidelines, and professional advice. Similarly, recurring energy related problems are toughly presented (i.e. thermal characterization of buildings; thermal bridging, insulation level, air leakage and moisture detection; indoor temperature and U-value measurements; human comfort assessment). Finally, advantages and potential sources of errors as well as future trends in the use of IRT for the energy audit have been described. The research aims to serve as a reference for energy auditors and thermographers, to decide upon the best procedure for detecting specific energy defects.
引用
收藏
页码:3077 / 3090
页数:14
相关论文
共 50 条
  • [21] AERODYNAMIC APPLICATIONS OF INFRARED THERMOGRAPHY
    DARYABEIGI, K
    ALDERFER, DW
    INFRARED TECHNOLOGY XV, 1989, 1157 : 166 - 175
  • [22] Industrial applications of infrared thermography
    Balageas, D
    Krapez, JC
    Legrandjacques, L
    Lepoutre, F
    Petry, H
    PHOTOACOUSTIC AND PHOTOTHERMAL PHENOMENA: TENTH INTERNATIONAL CONFERENCE, 1999, 463 : 357 - 361
  • [23] Veterinary applications of infrared thermography
    Rekant, Steven I.
    Lyons, Mark A.
    Pacheco, Juan M.
    Arzt, Jonathan
    Rodriguez, Luis L.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2016, 77 (01) : 98 - 107
  • [24] Thermal Imagery Based Instance Segmentation for Energy Audit Applications in Buildings
    Arjoune, Youness
    Peri, Sai
    Sugunaraj, Niroop
    Sadhukhan, Debanjan
    Nord, Michael
    Krishnamoorthy, Gautham
    Flynn, David
    Ranganathan, Prakash
    2019 IEEE INTERNATIONAL CONFERENCE ON BIG DATA (BIG DATA), 2019, : 5974 - 5976
  • [25] Infrared Screening of Residential Buildings for Energy Audit Purposes: Results of a Field Test
    Dall'O', Giuliano
    Sarto, Luca
    Panza, Angela
    ENERGIES, 2013, 6 (08): : 3859 - 3878
  • [26] Clinical applications of dynamic infrared thermography in plastic surgery: a systematic review
    John, Hannah Eliza
    Niumsawatt, Vachara
    Rozen, Warren Matthew
    Whitaker, Iain S.
    GLAND SURGERY, 2016, 5 (02) : 122 - 132
  • [27] Musculoskeletal applications of infrared thermography on back and neck syndromes: a systematic review
    Albuquerque, Nelson F.
    Lopes, Bruno S.
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2021, 57 (03) : 386 - 396
  • [28] Heat transfer modeling using analytical solutions for infrared thermography applications in multilayered buildings systems
    Serra, C.
    Tadeu, A.
    Simoes, N.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 115 : 471 - 478
  • [29] Effects of individual climatic parameters on the infrared thermography of buildings
    Lehmann, B.
    Ghazi Wakili, K.
    Frank, Th.
    Collado, B. Vera
    Tanner, Ch.
    APPLIED ENERGY, 2013, 110 : 29 - 43
  • [30] Experiences of infrared thermography in electronics applications
    Lehtiniemi, R
    Rantala, J
    THERMOSENSE XXI, 1999, 3700 : 112 - 120