Monte Carlo investigation of a high-efficiency, two-plane Compton camera for long-range localization of radioactive materials

被引:8
|
作者
Poitrasson-Riviere, Alexis [1 ]
Maestas, Ben A. [1 ]
Hamel, Michael C. [1 ]
Clarke, Shaun D. [1 ]
Flaska, Marek [1 ]
Pozzi, Sara A. [1 ]
Pausch, Guntram [2 ]
Herbach, Claus-Michael [2 ]
Gueorguiev, Andrey [2 ]
Ohmes, Martin F. [2 ]
Stein, Juergen [2 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Detect Nucl Nonproliferat Grp, Ann Arbor, MI 48109 USA
[2] FLIR Radiat GmbH, D-42651 Solingen, Germany
关键词
Compton imaging; Gamma rays; Monte Carlo simulations; Organic scintillators; Inorganic scintillators; GAMMA-CAMERA; SENSITIVITY; RESOLUTION;
D O I
10.1016/j.pnucene.2015.01.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Compton cameras have become an instrument of interest for long-range localization of radioactive materials in nuclear-nonproliferation applications. In this work, a specialized simulation tool was developed for the optimization of a Compton camera through realistic Monte Carlo simulations. This tool can be used for Compton cameras with different geometries. The MCNPX-PoliMi code was used to simulate Compton scatters and photoelectric absorptions in the camera's detectors. The imaging capability is derived from the physics of Compton scattering and the full-energy information obtained in photoelectric absorptions. The simulated system is a 1 x 1 m(2) Compton camera consisting of two planar arrays of photon detectors. Several scintillators were evaluated: LaBr3, CaF2, and NaI(Tl) (all inorganic scintillators), and C9H10 (plastic organic scintillator). The investigation was carried out with a Cs-137 source. A minimum detectable activity (MDA) was defined and used to assess the performance of cameras based on different detectors. The simulation results show that C9H10 is a reliable, low-cost, scatter-plane material, increasing the MDA by similar to 0.2 mCi when compared to a CaF2 scatter plane. On the other hand, the intrinsic background of LaBr3 undermines its above-average energy resolution as the MDA increased by similar to 0.5 mCi when compared to a NaI(TI) absorption plane. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 1 条
  • [1] Monte Carlo Investigation of a High-Sensitivity Two-Plane Compton Camera for Long-Range Detection of SNM
    Maestas, Ben A.
    Clarke, Shaun D.
    Flaska, Marek
    Pozzi, Sara A.
    Poitrasson-Riviere, Alexis
    Pausch, Guntram
    Herbach, Claus-Michael
    Guergueiev, Andrey
    Ohmes, Martin
    Stein, Juergen
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 964 - +