Simultaneous determination of silver and gold nanoparticles by cloud point extraction and total reflection X-ray fluorescence analysis

被引:23
|
作者
Bahadir, Z. [1 ,2 ]
Torrent, L. [2 ]
Hidalgo, M. [2 ]
Margui, E. [2 ]
机构
[1] Giresun Univ, Fac Sci & Arts, Dept Chem, TR-28100 Giresun, Turkey
[2] Univ Girona, Fac Sci, Dept Chem, C-M Aurelia Campmany 69, Girona 17003, Spain
关键词
Gold nanoparticles; Silver nanoparticles; CPE; TXRF; Water; WATER SAMPLES; METALLIC NANOPARTICLES; ENVIRONMENTAL WATER; PRECONCENTRATION; SPECTROMETRY; QUANTIFICATION; SEPARATION; SPECIATION; CHEMISTRY; EXPOSURE;
D O I
10.1016/j.sab.2018.07.016
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
While the nanoscale dimensions give metallic nanoparticles unique physical and chemical properties, their potential release in the environment and subsequent effects on ecosystem health are becoming an increasing concern. In the present contribution, for the first time, a novel and simple analytical approach has been developed for the simultaneous quantification of silver and gold nanoparticles (AgNPs, AuNPs) in aqueous samples. The method combines a sample preparation and enrichment step based on cloud point extraction (CPE) with total reflection X-ray fluorescence spectrometry (TXRF) detection. Experimental conditions enabling the simultaneous extraction and detection of AgNPs and AuNPs were studied in detail. Under the best analytical conditions, limits of detection for AgNPs and AuNPs were 0.3 and 0.2 mu g L-1, respectively. Due to the lack of suitable certified references materials, accuracy of the CPE-TXRF method was tested by analysing several types of spiked water samples, including mineral, tap, river and sea water. Percentage recoveries achieved for the analysis of spiked samples were in all cases in the range of 82-100% for both types of studied NPs, suggesting that the existence of natural colloids, ionic Ag+ and Au3+ species, and other components in environmental waters have little influence on the quantitative determination of AgNPs and AuNPs. The only exception was the recovery obtained in the analysis of the spiked sea water sample that was around 40-50%. However, for salty aqueous samples, the developed analytical approach might still be feasible if the standard addition method is used for calibration purposes. In an attempt to provide additional information on AgNPs and AuNPs behaviour in the environment, the CPE-TXRF method was also applied to study the influence of organic matter content in waters as well as the influence of soil matrix on AgNPs and AuNPs stability.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 50 条
  • [1] Determination of silver nanoparticles in complex aqueous matrices by total reflection X-ray fluorescence spectrometry combined with cloud point extraction
    Torrent, Laura
    Iglesias, Monica
    Hidalgo, Manuela
    Margui, Eva
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (03) : 383 - 394
  • [2] Quantification of gold nanoparticles in blood using total reflection X-ray fluorescence
    Mankovskii, Gabriella
    Pejovic-Milic, Ana
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 194
  • [3] Total reflection X-ray fluorescence
    Schmeling, Martina
    PHYSICAL SCIENCES REVIEWS, 2019, 4 (07)
  • [4] Analytical capabilities of total reflection X-ray fluorescence spectrometry for silver nanoparticles determination in soil adsorption studies
    Torrent, Laura
    Iglesias, Monica
    Hidalgo, Manuela
    Margui, Eva
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 126 : 71 - 78
  • [5] Simultaneous determination of Os, Ir, Pt and Au in sorbent phases by total reflection X-ray fluorescence
    Maksimova, Yulia A.
    Dubenskiy, Alexander S.
    Garmash, Andrey V.
    V. Pashkova, Galina V.
    V. Shigapov, Ilya V.
    Seregina, Irina F.
    Pavlova, Lyudmila A.
    Sharanov, Pavel Yu.
    Bolshov, Mikhail A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 196
  • [6] Evaluation of analysis volume in total reflection X-ray fluorescence analysis
    Tsuji, Kouichi
    Taniguchi, Naoya
    Yamaguchi, Hiroki
    Matsuyama, Tsugufumi
    X-RAY SPECTROMETRY, 2023, 52 (06) : 357 - 363
  • [7] Determination of fluorine by total reflection X-ray fluorescence spectrometry
    Tarsoly, G.
    Ovari, M.
    Zaray, Gy.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (04) : 287 - 290
  • [8] Influence of the sample morphology on total reflection X-ray fluorescence analysis
    Horntrich, C.
    Meirer, F.
    Streli, C.
    Kregsamer, P.
    Pepponi, G.
    Zoeger, N.
    Wobrauschek, P.
    POWDER DIFFRACTION, 2009, 24 (02) : 140 - 144
  • [9] Summary of ISO standard 20289: Total reflection X-ray fluorescence analysis of water
    Borgese, Laura
    Bilo, Fabjola
    Federici, Stefania
    Margui, Eva
    Hase, Thomas
    Huang, Yuying
    Beckhoff, Burkhard
    Depero, Laura E.
    SURFACE AND INTERFACE ANALYSIS, 2020, 52 (03) : 119 - 123
  • [10] Determination of technetium by total reflection X-ray fluorescence
    Bermúdez, JI
    Greaves, ED
    Nemeth, P
    Sajo-Bohus, L
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2247 - 2251