Determination of phenol in soil sample as an environmental pollution using aminophenol modified glassy carbon sensor electrode

被引:0
作者
Mulazimoglu, Ibrahim Ender [1 ]
机构
[1] Selcuk Univ, Ahmet Kelesoglu Educ Fac, Dept Chem, Konya, Turkey
来源
ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH | 2011年 / 28卷 / 01期
关键词
2,4-diaminophenol; Aminophenol diazonium salt; Cyclic voltammetry; Glassy carbon sensor electrode; STRIPPING VOLTAMMETRIC DETERMINATION; COVALENT MODIFICATION; ELECTROCHEMICAL-BEHAVIOR; PASTE ELECTRODE; SURFACES; ACID; PROCAINE; COMPLEX; ENERGY;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a simple and sensitive method for the electrochemical determination of phenol in soil sample using disposable screen-printed glassy carbon (GC) electrode surface modified with an electrografted aminophenol film, via the electrochemical reduction of its prepared aminophenol diazonium salt in non-aqueous media, is presented. 1 mM of aminophenol diazonium salt (APDAS) in 100 mM tetrabutylammonium tetrafluoroborate (TBATFB) was used for modification of GC electrode surface in this study. The surface modification of GC electrode was performed with aminophenol (AP) using cyclic voltammetry (CV), whereas the characterization of this sensor electrode was performed using CV and electrochemical impedance spectroscopy. The modification process was carried out in non-aqueous media, whereas phenol determination was carried out in aqueous media. Acetonitrile (MeCN) for providing non-aqueous condition and Britton-Robinson (BR) buffer solution at pH 10 and 100 mM KCl solution for providing aqueous condition were used. As the final of this study, a reaction mechanism was suggested for the binding of phenol to aminophenol modified GC electrode surface. 0.1316 mgL(-1) phenol was determined in soil sample by using AP modified GC electrode.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 50 条
  • [21] Adsorption Studies and Selective Determination of Epinephrine at Glycerol-Clay Modified Glassy Carbon Electrode
    Agyeman, Augustine O.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (10): : 9601 - 9618
  • [22] An electrochemical nanocomposite modified carbon paste electrode as a sensor for simultaneous determination of hydrazine and phenol in water and wastewater samples
    Karimi-Maleh, Hassan
    Moazampour, Mahbobeh
    Ensafi, Ali A.
    Mallakpour, Shadpour
    Hatami, Mehdi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (09) : 5879 - 5888
  • [23] Visible Light Photoelectrochemical Sensor for Acetaminophen Determination using a Glassy Carbon Electrode Modified with BiVO4 Nanoparticles
    Araujo, Mayara da Silva
    Barretto, Tulio Rolim
    Rolim Galvao, Juliana Costa
    Teixeira Tarley, Cesar Ricardo
    Dall'Antonia, Luiz Henrrique
    de Matos, Roberto
    Medeiros, Roberta Antigo
    ELECTROANALYSIS, 2021, 33 (03) : 663 - 671
  • [24] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of noscapine in biological and pharmaceutical samples
    Rezaei, Behzad
    Zare, S. Zohreh Mirahmadi
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01): : 292 - 299
  • [25] Electrochemical Sensor Using Glassy Carbon Electrode Modified with HPMαFP/Ppy/GCE Composite Film for Determination of Ofloxacin
    Han, Hui
    Li, Jin-Zhou
    Pang, Xiao-Zhe
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 9060 - 9070
  • [26] Determination of analgesics in pharmaceutical formulations and urine samples using nano polypyrrole modified glassy carbon electrode
    Muralidharan, B.
    Gopu, G.
    Vedhi, C.
    Manisankar, P.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (08) : 1177 - 1184
  • [27] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples
    Rezaei, B.
    Zare, Z. Mirahmadi
    ANALYTICAL LETTERS, 2008, 41 (12) : 2267 - 2286
  • [28] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [29] Determination of levodopa using a glassy carbon electrode modified with TiO2 nanoparticles and carbon nanotubes in real samples
    Ebrahimi, Fatemeh
    Rafati, Amir Abbas
    Bagheri, Ahmad
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (11) : 3985 - 3998
  • [30] DETERMINATION OF ISONIAZID BY USING ROOM TEMPERATURE IONIC LIQUIDS MODIFIED GLASSY CARBON ELECTRODE
    Behnamipour, S.
    Abbasi, K. H.
    Rouhollahi, A.
    Ardakani, Mazloum M.
    Haghgoo, S.
    Arast, Y.
    ACTA MEDICA MEDITERRANEA, 2016, 32 : 1549 - 1553