Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy

被引:485
作者
Wang, H
Dong, L
O'Daniel, J
Mohan, R
Garden, AS
Ang, KK
Kuban, DA
Bonnen, M
Chang, JY
Cheung, R
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
关键词
D O I
10.1088/0031-9155/50/12/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A greyscale-based fully automatic deformable image registration algorithm, originally known as the 'demons' algorithm, was implemented for CT image-guided radiotherapy. We accelerated the algorithm by introducing an 'active force' along with an adaptive force strength adjustment during the iterative process. These improvements led to a 40% speed improvement over the original algorithm and a high tolerance of large organ deformations. We used three methods to evaluate the accuracy of the algorithm. First, we created a set of mathematical transformations for a series of patient's CT images. This provides a 'ground truth' solution for quantitatively validating the deformable image registration algorithm. Second, we used a physically deformable pelvic phantom, which can measure deformed objects under different conditions. The results of these two tests allowed us to quantify the accuracy of the deformable registration. Validation results showed that more than 96% of the voxels were within 2 mm of their intended shifts for a prostate and a head-and-neck patient case. The mean errors and standard deviations were 0.5 mm 1.5 mm and 0.2 mm +/- 0.6 mm, respectively. Using the deformable pelvis phantom, the result showed a tracking accuracy of better than 1.5 mm for 23 seeds implanted in a phantom prostate that was deformed by inflation of a rectal balloon. Third, physician-drawn contours outlining the tumour volumes and certain anatomical structures in the original CT images were deformed along with the CT images acquired during subsequent treatments or during a different respiratory phase for a lung cancer case. Visual inspection of the positions and shapes of these deformed contours agreed well with human judgment. Together, these results suggest that the accelerated demons algorithm has significant potential for delineating and tracking doses in targets and critical structures during CT-guided radiotherapy.
引用
收藏
页码:2887 / 2905
页数:19
相关论文
共 50 条
[41]  
Tichavsky P, 2002, INT CONF ACOUST SPEE, P2841
[42]  
Valverde FL, 2001, 2001 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, P82, DOI 10.1109/ICIP.2001.958056
[43]  
Vemuri B C, 1998, Med Image Anal, V2, P79, DOI 10.1016/S1361-8415(01)80029-3
[44]   Implementation and validation of a three-dimensional deformable registration algorithm for targeted prostate cancer radiotherapy [J].
Wang, H ;
Dong, L ;
Lii, MF ;
Lee, AL ;
De Crevoisier, R ;
Mohan, R ;
Cox, JD ;
Kuban, DA ;
Cheung, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :725-735
[45]  
Wang H, 2000, P ANN INT IEEE EMBS, V22, P2850, DOI 10.1109/IEMBS.2000.901462
[46]   Automated image registration: I. General methods and intrasubject, intramodality validation [J].
Woods, RP ;
Grafton, ST ;
Holmes, CJ ;
Cherry, SR ;
Mazziotta, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (01) :139-152
[47]   A voxel-based method for the statistical analysis of gray and white matter density applied to schizophrenia [J].
Wright, IC ;
McGuire, PK ;
Poline, JB ;
Travere, JM ;
Murray, RM ;
Frith, CD ;
Frackowiak, RSJ ;
Friston, KJ .
NEUROIMAGE, 1995, 2 (04) :244-252
[48]   Two algorithms for non-rigid image registration and their evaluation [J].
Xie, ZY ;
Ng, L ;
Gee, J .
MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 :157-164
[49]   A model to accumulate fractionated dose in a deforming organ [J].
Yan, D ;
Jaffray, DA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (03) :665-675
[50]   Organ/patient geometric variation in external beam radiotherapy and its effects [J].
Yan, D ;
Lockman, D .