RF coil design for low and high field MRI: numerical methods and measurements

被引:0
|
作者
Stara, Riccardo [1 ,4 ]
Fontana, Nunzia [3 ,4 ]
Alecci, Marcello [4 ,7 ]
Alfonsetti, Maria [4 ,7 ]
Galante, Angelo [4 ,7 ]
Vitacolonna, Assunta [4 ,7 ]
Biagi, Laura [4 ,6 ]
Buonincontri, Guido [2 ]
Del Guerra, Alberto [1 ,4 ]
Tosetti, Michela [4 ,6 ]
Manara, Giuliano [3 ,4 ]
Monorchio, Agostino [3 ,4 ]
Tiberi, Gianluigi [3 ,5 ]
Retico, Alessandra [4 ]
机构
[1] Univ Pisa, Dept Phys, I-56100 Pisa, Italy
[2] Univ Cambridge, Cambridge, England
[3] Univ Pisa, Dept Engn, Pisa, Italy
[4] Ist Nazl Fis Nucl, Pisa, Italy
[5] Imago7 Fdn, Pisa, Italy
[6] Sci Inst Stella Maris, Pisa, Italy
[7] Univ Laquila, Dipartimento Sci Salute, Laquila, Italy
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
MRI; radiofrequency coil; surface coil; TEM; MoM; FEM; UHFMRI;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several clinical magnetic resonance applications at 1.5 T and higher field strengths require a careful selection of the RadioFrequency (RF) coil design to optimize the RF spatial distribution and sensitivity. Specifically, two basic requirements must be fulfilled for obtaining high quality images: in the transmission mode, RF coils must be able to produce a uniform magnetic field in the volume of interest so that the nuclei can be properly excited; in the receiving mode, a high signal to noise ratio is needed, and the coil must be able to collect the signal emitted by the nuclei with better sensitivity throughout the volume of interest. A number of analytical and numerical methods are reported in the literature to simulate the RF field distributions of surface and volume coils. In this work, we compared the performances of two computational methods (Method of Moments and Finite Elements Method), considering the modelling of both surface (single loop, figure of eight coil. FO8, dual loop) and volume (TEM) coils. Low (1.5 T) and high (7 T) field operating regimes have been analysed. Measurements obtained on the workbench and with a 1.5 T scanner are used for validation.
引用
收藏
页码:3465 / 3469
页数:5
相关论文
共 50 条
  • [21] Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications
    Alfonsetti, M
    Clementi, V
    Iotti, S
    Placidi, G
    Lodi, R
    Barbiroli, B
    Sotgiu, A
    Alecei, M
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (02) : 69 - 75
  • [22] Numerical Evaluation on Irregular Field Generated by Screening Current in High-Field REBCO Coil for Whole-Body MRI
    Nakazono, Kohei
    Ueda, Hiroshi
    Ishiyama, Atsushi
    Noguchi, So
    Miyazaki, Hiroshi
    Tosaka, Taizo
    Kurusu, Tsutomu
    Nomura, Shunji
    Urayama, Shinichi
    Fukuyama, Hidenao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [23] Integration of Electro-textile RF Coil Array with Magnetic Resonance Imaging (MRI) System: Design Strategies and Characterization Methods
    Zhang, Daisong
    Rahmat-Samii, Yahya
    2018 IEEE INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2018,
  • [24] Ultra-high field MRI: parallel-transmit arrays and RF pulse design
    Williams, Sydney N.
    McElhinney, Paul
    Gunamony, Shajan
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (02)
  • [25] Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications
    M. Alfonsetti
    V. Clementi
    S. Iotti
    G. Placidi
    R. Lodi
    B. Barbiroli
    A. Sotgiu
    M. Alecci
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 69 - 75
  • [26] An inverse methodology for high-frequency RF coil design for MRI with de-emphasized B1 fields
    Xu, B
    Wei, Q
    Liu, F
    Crozier, S
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (09) : 1582 - 1587
  • [27] A hybrid FDTD/MoM algorithm with a non-uniform grid for MRI RF coil design
    Liu, Yang
    Wang, Qiuliang
    Liu, Feng
    MAGNETIC RESONANCE IMAGING, 2023, 96 : 75 - 84
  • [28] Challenging the Lumped Birdcage Coil Model for High-Field MRI
    Puddu, Claudio
    Fanti, Alessandro
    Curreli, Nicola
    Mazzarella, Giuseppe
    2014 LOUGHBOROUGH ANTENNAS AND PROPAGATION CONFERENCE (LAPC), 2014, : 308 - 311
  • [29] Low-cost inductively coupled stacked wireless RF coil for MRI at 3 T
    Lu, Ming
    Chai, Shuyang
    Zhu, Haoqin
    Yan, Xinqiang
    NMR IN BIOMEDICINE, 2023, 36 (01)
  • [30] Design of Hexagonal RF Surface coil for 3T MRI Scanner by Characteristic Mode Analysis
    Ullah, Rafi
    Venkatesan, Soundarya
    2022 IEEE MICROWAVES, ANTENNAS, AND PROPAGATION CONFERENCE, MAPCON, 2022, : 1100 - 1103