RF coil design for low and high field MRI: numerical methods and measurements

被引:0
|
作者
Stara, Riccardo [1 ,4 ]
Fontana, Nunzia [3 ,4 ]
Alecci, Marcello [4 ,7 ]
Alfonsetti, Maria [4 ,7 ]
Galante, Angelo [4 ,7 ]
Vitacolonna, Assunta [4 ,7 ]
Biagi, Laura [4 ,6 ]
Buonincontri, Guido [2 ]
Del Guerra, Alberto [1 ,4 ]
Tosetti, Michela [4 ,6 ]
Manara, Giuliano [3 ,4 ]
Monorchio, Agostino [3 ,4 ]
Tiberi, Gianluigi [3 ,5 ]
Retico, Alessandra [4 ]
机构
[1] Univ Pisa, Dept Phys, I-56100 Pisa, Italy
[2] Univ Cambridge, Cambridge, England
[3] Univ Pisa, Dept Engn, Pisa, Italy
[4] Ist Nazl Fis Nucl, Pisa, Italy
[5] Imago7 Fdn, Pisa, Italy
[6] Sci Inst Stella Maris, Pisa, Italy
[7] Univ Laquila, Dipartimento Sci Salute, Laquila, Italy
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
MRI; radiofrequency coil; surface coil; TEM; MoM; FEM; UHFMRI;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several clinical magnetic resonance applications at 1.5 T and higher field strengths require a careful selection of the RadioFrequency (RF) coil design to optimize the RF spatial distribution and sensitivity. Specifically, two basic requirements must be fulfilled for obtaining high quality images: in the transmission mode, RF coils must be able to produce a uniform magnetic field in the volume of interest so that the nuclei can be properly excited; in the receiving mode, a high signal to noise ratio is needed, and the coil must be able to collect the signal emitted by the nuclei with better sensitivity throughout the volume of interest. A number of analytical and numerical methods are reported in the literature to simulate the RF field distributions of surface and volume coils. In this work, we compared the performances of two computational methods (Method of Moments and Finite Elements Method), considering the modelling of both surface (single loop, figure of eight coil. FO8, dual loop) and volume (TEM) coils. Low (1.5 T) and high (7 T) field operating regimes have been analysed. Measurements obtained on the workbench and with a 1.5 T scanner are used for validation.
引用
收藏
页码:3465 / 3469
页数:5
相关论文
共 50 条
  • [1] Design and simulation of a RF coil for a dedicated low-field MRI system
    Asfour, A
    Maliverney, P
    Fournier, JM
    Raoof, K
    METMBS '04: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MATHEMATICS AND ENGINEERING TECHNIQUES IN MEDICINE AND BIOLOGICAL SCIENCES, 2004, : 187 - 190
  • [2] A High Temperature Superconducting Imaging Coil for Low-Field MRI
    Cheong, Hoon-Sin
    Wild, James
    Alford, Neil
    Valkov, Ivelin
    Randell, Christopher
    Paley, Martyn
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2010, 37B (02) : 56 - 64
  • [3] Microstrip RF surface coil design for extremely high-field MRI and spectroscopy
    Zhang, XL
    Ugurbil, K
    Chen, W
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 443 - 450
  • [4] Numerical Design of Dual Resonant Microstrip Surface RF Coil for MRI Application
    Mahendra, Adhi
    Basari
    Rahardjo, Eko Tjipto
    2019 IEEE INTERNATIONAL CONFERENCE ON ANTENNA MEASUREMENTS & APPLICATIONS (CAMA), 2019, : 320 - 322
  • [5] Flat RF body coil design for open MRI
    Boskamp, EB
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2387 - 2389
  • [6] An inverse methodology for high frequency RF head coil design with pre-emphasized B1 field in MRI
    Xu, B
    Crozier, S
    Li, BK
    Wei, Q
    Liu, F
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1128 - 1131
  • [7] Numerical Design of RF Birdcage Coil without Lumped Elements for MRI 3T System
    Basari
    Priatna, Arwan
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 INTERNATIONAL CONFERENCE QUALITY IN RESEARCH (QIR), 2015, : 90 - 93
  • [8] An inverse design of an open, head/neck RF coil for MRI
    Lawrence, BG
    Crozier, S
    Cowin, G
    Yau, DD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) : 1024 - 1030
  • [9] Design Decoupling Methods of Multichannel Phased Array Receive Only RF Coil for Different Structures of 1.5T MRI
    Dapkar, Radhika
    Ugle, Niket
    Bagchi, Soumendu
    Bhuiya, Tapas
    Kulkarni, A. M.
    Gaikwad, Sandeep
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, : 606 - 610
  • [10] Integration of an RF coil and commercial field camera for ultrahigh-field MRI
    Gilbert, Kyle M.
    Dubovan, Paul, I
    Gati, Joseph S.
    Menon, Ravi S.
    Baron, Corey A.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2551 - 2565