Postblink changes in the ocular modulation transfer function measured by a double-pass method

被引:46
作者
Montés-Micó, R
Alió, JL
Charman, WN
机构
[1] VISSUM Inst Oftalmol de Alicante, Dev & Innovat Dept, Alicante 03016, Spain
[2] Univ Murcia, Dept Ophthalm Otorhinolaryngol & Pathol, Murcia, Spain
[3] Univ Miguel Hernandez, Sch Med, Alicante, Spain
[4] Univ Manchester, Fac Life Sci, Dept Optometry & Neurosci, Manchester, Lancs, England
关键词
D O I
10.1167/iovs.05-0609
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To examine the temporal changes in the modulation transfer function (MTF) of the eye after a blink. METHODS. The distance MTF of a 5-mm pupil was derived from double-pass retinal images in 20 healthy young subjects at various intervals after a blink (1 second up to 15 seconds). Such measurements include the effects of wavefront aberration, scattered light, and errors in focus and are thus more relevant to real life than are estimates of MTF based on wavefront errors alone. RESULTS. Optimal MTF by a variety of criteria was found some 6 seconds after a blink. CONCLUSIONS. Inclusion of the effects of stray light and errors of focus does not affect the finding that optimal retinal image quality occurs some time after a blink. It does not appear that a loss in optical quality is the trigger of normal blinking.
引用
收藏
页码:4468 / 4473
页数:6
相关论文
共 46 条
  • [1] Albarran C, 1997, Cont Lens Anterior Eye, V20, P129, DOI 10.1016/S1367-0484(97)80011-2
  • [2] ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    WILLIAMS, DR
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02): : 195 - 201
  • [3] CALCULATIONS OF 2-DIMENSIONAL FOVEAL RETINAL IMAGES IN REAL EYES
    ARTAL, P
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (08): : 1374 - 1381
  • [4] DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM
    ARTAL, P
    IGLESIAS, I
    LOPEZGIL, N
    GREEN, DG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10): : 2358 - 2366
  • [5] BENEDETTO DA, 1984, ARCH OPHTHALMOL-CHIC, V102, P410
  • [6] SURFACE-TENSION GRADIENT MECHANISM FOR DRIVING PRECORNEAL TEAR FILM AFTER A BLINK
    BERGER, RE
    CORRSIN, S
    [J]. JOURNAL OF BIOMECHANICS, 1974, 7 (03) : 225 - &
  • [7] Berny F., 1969, OPTICAL INSTRUMENTS, P375
  • [8] BROWN SI, 1970, ARCH OPHTHALMOL-CHIC, V83, P542
  • [9] The stability of corneal topography in the post-blink interval
    Buehren, T
    Collins, MJ
    Iskander, DR
    Davis, B
    Lingelbach, B
    [J]. CORNEA, 2001, 20 (08) : 826 - 833
  • [10] OPTICAL QUALITY OF HUMAN EYE
    CAMPBELL, FW
    GUBISCH, RW
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1966, 186 (03): : 558 - +