Artificial chamber and 3D printed iris: a new wet lab model for teaching Descemet's membrane endothelial keratoplasty

被引:21
作者
Famery, Nicolas [1 ]
Abdelmassih, Youssef [1 ]
El-Khoury, Sylvain [1 ]
Guindolet, Damien [1 ]
Cochereau, Isabelle [1 ,2 ,3 ]
Gabison, Eric E. [1 ,2 ,3 ]
机构
[1] Fdn Ophtalmol A de Rothschild, Cornea External Disorders & Refract Surg Dept, Paris, France
[2] Hosp Bichat Claude Bernard, Paris, France
[3] Paris Diderot Univ, Paris, France
关键词
artificial anterior chamber; artificial iris; Descemet membrane endothelial keratoplasty; endothelial keratoplasty; wet lab; SURGERY; SIMULATOR; DEPTH; EYES;
D O I
10.1111/aos.13852
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To describe a new wet lab model of Descemet membrane endothelial keratoplasty (DMEK) using human corneas mounted on an artificial anterior chamber with an artificial iris and to compare the performance time and scores between beginners and experienced anterior segment surgeons. Methods Corneas were mounted on an artificial chamber. To simulate an anterior chamber and to avoid loosing the graft into the tubing, a 3D printed iris was added. Each DMEK procedure required only one cornea for graft preparation, insertion, orientation, unfolding and centration. Ten human research corneas were used for training purposes. Intraoperative OCT was only used to validate the different steps of the procedure. Operators were divided into two groups, two beginners and three experienced DMEK surgeons. Results All DMEK procedures were successfully performed. Descemet's tears were frequent but harvesting was successful in all procedures. All combinations of graft unfolding techniques were possible. Experienced surgeons performed statistically better then beginners with faster harvesting (12.8 versus 28.2 min; p = 0.02) and insertion (13.5 versus 20.8 min; p = 0.05) times and better performance score (94 versus 52; p = 0.03). Conclusion This DMEK wet lab model offers a close to reality, feasible, resource-sparing and valid teaching technique that permits to perform all DMEK surgical steps. It also offers the possibility of varying the surgical difficulty by changing the anterior chamber depth.
引用
收藏
页码:E179 / E183
页数:5
相关论文
共 19 条
  • [1] Influence of surgery simulator training on ophthalmology resident phacoemulsification performance
    Belyea, David A.
    Brown, Sarah E.
    Rajjoub, Lamise Z.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10) : 1756 - 1761
  • [2] Impact of Surgical Learning Curve in Descemet Membrane Endothelial Keratoplasty on Visual Acuity Gain
    Debellemaniere, Guillaume
    Guilbert, Emmanuel
    Courtin, Romain
    Panthier, Christophe
    Sabatier, Patrick
    Gatinel, Damien
    Saad, Alain
    [J]. CORNEA, 2017, 36 (01) : 1 - 6
  • [3] Descemet Membrane Endothelial Keratoplasty: Safety and Outcomes A Report by the American Academy of Ophthalmology
    Deng, Sophie X.
    Lee, W. Barry
    Hammersmith, Kristin M.
    Kuo, Anthony N.
    Li, Jennifer Y.
    Shen, Joanne F.
    Weikert, Mitchell P.
    Shtein, Roni M.
    [J]. OPHTHALMOLOGY, 2018, 125 (02) : 295 - 310
  • [4] A simple ex vivo model for teaching Descemet membrane endothelial keratoplasty
    Droutsas, Konstantinos
    Petrak, Michael
    Melles, Gerrit R. J.
    Koutsandrea, Chryssanthi
    Georgalas, Ilias
    Sekundo, Walter
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92 (05) : E362 - E365
  • [5] Virtual reality training improves wet-lab performance of capsulorhexis: results of a randomized, controlled study
    Feudner, Elisabeth M.
    Engel, Corinna
    Neuhann, Irmingard M.
    Petermeier, Katrin
    Bartz-Schmidt, Karl-Ulrich
    Szurman, Peter
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (07) : 955 - 963
  • [6] Endothelial Keratoplasty: Fellow Eyes Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty
    Guerra, Frederico P.
    Anshu, Arundhati
    Price, Marianne O.
    Price, Francis W.
    [J]. CORNEA, 2011, 30 (12) : 1382 - 1386
  • [7] The First 100 Eyes of Standardized Descemet Stripping Automated Endothelial Keratoplasty versus Standardized Descemet Membrane Endothelial Keratoplasty
    Hamzaoglu, Ebru C.
    Straiko, Michael D.
    Mayko, Zachary M.
    Sales, Christopher S.
    Terry, Mark A.
    [J]. OPHTHALMOLOGY, 2015, 122 (11) : 2193 - 2199
  • [8] Keenan TDL, 2012, ARCH OPHTHALMOL-CHIC, V130, P621, DOI 10.1001/archophthalmol.2011.2585
  • [9] Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes
    Kriechbaum, K
    Findl, O
    Kiss, B
    Sacu, S
    Petternel, V
    Drexler, W
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01) : 89 - 94
  • [10] Donor tissue preparation for Descemet membrane endothelial keratoplasty
    Lie, Jessica T.
    Birbal, Renuka
    Ham, Lisanne
    van der Wees, Jacqueline
    Melles, Gerrit R. J.