Time-resolved all fiber fluorescence spectroscopy system

被引:0
作者
Chen, A. Y. H. [1 ]
Vanholsbeeck, F. [1 ]
Tai, D. C. S. [1 ]
Swift, S. [2 ,3 ]
Singhal, N. [3 ]
Harvey, J. D. [1 ,3 ]
Hooks, D. A.
Smaill, B. H.
机构
[1] Univ Auckland, Dept Phys, Private Bag 92019, Auckland, New Zealand
[2] Univ Auckland, Auckland, New Zealand
[3] Univ Auckland, Dept Phys, Auckland, New Zealand
来源
19TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2 | 2008年 / 7004卷
关键词
action potential; GFP; fluorescence; fiber probe; cardiac electrical activation; bioremediation;
D O I
10.1117/12.785967
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a simple fiber optic fluorescence spectrometry system with a wide variety of biomedical applications. This low-cost, all-fiber system is portable, robust and has the capacity to acquire fluorescence spectra at rates up to 1kHz. We demonstrate the capabilities of the system by presenting experimental measurements of action potentials in the di-4-ANEPPS stained heart and the concentration of GFP tagged bacteria.
引用
收藏
页数:4
相关论文
共 9 条
[1]   High-speed, random-access fluorescence microscopy: II. Fast quantitative measurements with voltage-sensitive dyes [J].
Bullen, A ;
Saggau, P .
BIOPHYSICAL JOURNAL, 1999, 76 (04) :2272-2287
[2]  
CRAWFORD RL, 1996, BIOREMEDIATION
[3]   Ratiometric intracellular calcium imaging in the isolated beating rat heart using indo-1 fluorescence [J].
Eerbeek, O ;
Mik, EG ;
Zuurbier, CJ ;
van 't Loo, M ;
Donkersloot, C ;
Ince, C .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (06) :2042-2050
[4]   The zebrafish lysozyme C promoter drives myeloid-specific expression in transgenic fish [J].
Hall, Chris ;
Flores, Maria Vega ;
Storm, Thilo ;
Crosier, Kathy ;
Crosier, Phil .
BMC DEVELOPMENTAL BIOLOGY, 2007, 7
[5]   Intramural multisite recording of transmembrane potential in the heart [J].
Hooks, DA ;
LeGrice, IJ ;
Harvey, JD ;
Smaill, BH .
BIOPHYSICAL JOURNAL, 2001, 81 (05) :2671-2680
[6]   DESIGN AND USE OF AN OPTRODE FOR OPTICAL RECORDINGS OF CARDIAC ACTION-POTENTIALS [J].
NEUNLIST, M ;
ZOU, SZ ;
TUNG, L .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1992, 420 (5-6) :611-617
[7]   Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts [J].
Tai, DCS ;
Caldwell, BJ ;
LeGrice, IJ ;
Hooks, DA ;
Pullan, AJ ;
Smaill, BH .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (03) :H985-H993
[8]   Illumination and fluorescence collection volumes for fiber optic probes in tissue [J].
Tai, Dean C. S. ;
Hooks, Darren A. ;
Harvey, John D. ;
Smaill, Bruce H. ;
Soeller, Christian .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (03)
[9]   Fiber-optic fluorometer for microscale mapping of photosynthetic pigments in microbial communities [J].
Thar, R ;
Kühl, M ;
Holst, G .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (06) :2823-2828