An innovative sampling approach combined with liquid chromatography-tandem mass spectrometry for the analysis of emerging pollutants in drinking water

被引:11
|
作者
Di Carro, Marina [1 ]
Lluveras-Tenorio, Anna [2 ]
Benedetti, Barbara [1 ]
Magi, Emanuele [1 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, Via Dodecaneso 31, I-16146 Genoa, Italy
[2] Natl Interuniv Consortium Mat Sci & Technol, Via G Giusti 9, Florence, Italy
来源
JOURNAL OF MASS SPECTROMETRY | 2020年 / 55卷 / 11期
关键词
drinking water; emerging pollutants; liquid chromatography; tandem mass spectrometry; thin-film microextraction; THIN-FILM MICROEXTRACTION; SOLID-PHASE MICROEXTRACTION; PHARMACEUTICALS; OPTIMIZATION; CONTAMINANTS; PERFORMANCE; ENVIRONMENT; GEOMETRY; SYSTEM; FATE;
D O I
10.1002/jms.4608
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, an innovative sampling and preconcentration method followed by analysis with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization (LC-ESI-MS/MS) was developed for the determination of different emerging pollutants (five anti-inflammatory drugs and one antibacterial agent) in water matrices. Thin-film microextraction blades, consisting of stainless steel blades with a coating made of divinylbenzene, have been employed. The blades, fixed onto a stainless steel support, were mounted on a laboratory stirrer with adjustable speed, immersed in water samples and eluted with methanol. The analytical procedure was developed, carefully optimizing stirring speed and extraction time. A good reproducibility among the blades was observed; quantitation limits at the ng L(-1)level were achieved. Calibration curves were constructed by applying the whole procedure to tap water samples, free from analytes, spiked with standards in the concentration range 0.01-2 mu g L-1; good linearity was obtained, withR(2)between 0.9984 and 0.9991. The optimized method was applied to tap and surface waters; two anti-inflammatory drugs were detected at the ng L(-1)level in surface water. In one sample, diclofenac and naproxen were measured at 26 +/- 5 and 15 +/- 1 ng L-1, respectively; only diclofenac was quantified in the other sample at 14 +/- 3 ng L-1.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Successful adaption of a forensic toxicological screening workflow employing nontargeted liquid chromatography-tandem mass spectrometry to water analysis
    Steger, Julia
    Arnhard, Kathrin
    Haslacher, Sandra
    Geiger, Klemens
    Singer, Klaus
    Schlapp, Michael
    Pitterl, Florian
    Oberacher, Herbert
    ELECTROPHORESIS, 2016, 37 (7-8) : 1085 - 1094
  • [42] Simultaneous determination of fluoroquinolones in environmental water by liquid chromatography-tandem mass spectrometry with direct injection: A green approach
    Denadai, Marina
    Cass, Quezia Bezerra
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1418 : 177 - 184
  • [43] Rapid determination of free and conjugated estrogen in different water matrices by liquid chromatography-tandem mass spectrometry
    Kumar, Vimal
    Nakada, Norihide
    Yasojima, Makoto
    Yamashita, Naoyuki
    Johnson, Andrew C.
    Tanaka, Hiroaki
    CHEMOSPHERE, 2009, 77 (10) : 1440 - 1446
  • [44] Determination of Emerging Contaminants in Cereals by Gas Chromatography-Tandem Mass Spectrometry
    Albero, Beatriz
    Luis Tadeo, Jose
    Ana Perez, Rosa
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [45] Quantification of fluoroquinolones in wastewaters by liquid chromatography-tandem mass spectrometry
    Maia, Alexandra S.
    Paiga, Paula
    Delerue-Matos, Cristina
    Castro, Paula M. L.
    Tiritan, Maria Elizabeth
    ENVIRONMENTAL POLLUTION, 2020, 259
  • [46] Applicability of Adduct Detection in Liquid Chromatography-Tandem Mass Spectrometry
    Dziadosz, Marek
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (18) : 1671 - 1674
  • [47] Optimization of pressurized liquid extraction using a multivariate chemometric approach for the determination of anticancer drugs in sludge by ultra high performance liquid chromatography-tandem mass spectrometry
    Seira, Jordan
    Claparols, Catherine
    Joannis-Cassan, Claire
    Albasi, Claire
    Montrejaud-Vignoles, Mireille
    Sablayrolles, Caroline
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1283 : 27 - 38
  • [48] Identification of kinetin and kinetin riboside in coconut (Cocos nucifera L.) water using a combined approach of liquid chromatography-tandem mass spectrometry, high performance liquid chromatography and capillary electrophoresis
    Ge, L
    Yong, JWH
    Goh, NK
    Chia, LS
    Tan, SN
    Ong, ES
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2): : 26 - 34
  • [49] Rapid analysis of trace organic compounds in water by automated online solid-phase extraction coupled to liquid chromatography-tandem mass spectrometry
    Anumol, Tarun
    Snyder, Shane A.
    TALANTA, 2015, 132 : 77 - 86
  • [50] Determination of 115 Pesticide Residues in Textiles by Liquid Chromatography-Tandem Mass Spectrometry
    Li, Ying
    Ye, Xiwen
    Luo, Xin
    Zhu, Wenxuan
    Tang, Zhixu
    Niu, Zengyuan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2025, 39 (09)