A Comprehensive Cardiac Motion Estimation Framework Using Both Untagged and 3-D Tagged MR Images Based on Nonrigid Registration

被引:61
|
作者
Shi, Wenzhe [1 ]
Zhuang, Xiahai [2 ]
Wang, Haiyan [1 ]
Duckett, Simon
Luong, Duy V. N. [1 ]
Tobon-Gomez, Catalina [3 ]
Tung, KaiPin
Edwards, Philip J. [4 ]
Rhode, Kawal S. [5 ]
Razavi, Reza S. [5 ]
Ourselin, Sebastien [2 ]
Rueckert, Daniel [6 ,7 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Comp, London SW7 2AZ, England
[2] UCL, Dept Comp Sci, Ctr Med Image Comp, London WC1E 6BT, England
[3] Kings Coll London, Rayne Inst, London WC1E 6JF, England
[4] Univ London Imperial Coll Sci Technol & Med, St Marys Hosp, Dept Biosurg & Surg Technol, London W2 1NY, England
[5] Kings Coll London, St Thomas Hosp, Div Imaging Sci, London SE1 7EH, England
[6] Univ London Imperial Coll Sci Technol & Med, Dept Technol & Med, London SW7 2BZ, England
[7] Univ London Imperial Coll Sci Technol & Med, Dept Comp, London SW7 2BZ, England
基金
英国工程与自然科学研究理事会;
关键词
3-D tagging; cardiac function analysis; cardiac MR imaging; cardiac registration; motion tracking; segmentation; TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY; MAGNETIC-RESONANCE; MYOCARDIAL MOTION; HEART; SEGMENTATION; DEFORMATION; TRACKING;
D O I
10.1109/TMI.2012.2188104
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, we present a novel technique based on nonrigid image registration for myocardial motion estimation using both untagged and 3-D tagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both untagged and 3-D tagged MR images. To estimate the motion within the myocardium, we register a sequence of tagged and untagged MR images during the cardiac cycle to a set of reference tagged and untagged MR images at end-diastole. The similarity measure is spatially weighted to maximize the utility of information from both images. In addition, the proposed approach integrates a valve plane tracker and adaptive incompressibility into the framework. We have evaluated the proposed approach on 12 subjects. Our results show a clear improvement in terms of accuracy compared to approaches that use either 3-D tagged or untagged MR image information alone. The relative error compared to manually tracked landmarks is less than 15% throughout the cardiac cycle. Finally, we demonstrate the automatic analysis of cardiac function from the myocardial deformation fields.
引用
收藏
页码:1263 / 1275
页数:13
相关论文
共 50 条
  • [41] A dynamic 3-D cardiac surface model from MR images
    Delhay, B
    Lötjönen, J
    Clarysse, P
    Katila, T
    Magnin, IE
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 423 - 426
  • [42] 3-D/2-D registration of CT and MR to X-ray images
    Tomazevic, D
    Likar, B
    Slivnik, T
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1407 - 1416
  • [44] 3-D MOTION ESTIMATION USING A SEQUENCE OF NOISY STEREO IMAGES - MODELS, ESTIMATION, AND UNIQUENESS RESULTS
    YOUNG, GSJ
    CHELLAPPA, R
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (08) : 735 - 759
  • [45] Simulation based evaluation of cardiac motion estimation methods in tagged-MR Image sequences
    Patrick Clarysse
    Jean Tafazzoli
    Philippe Delachartre
    Pierre Croisille
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [46] Generating 3-D cardiac material markers using tagged MRI
    Kerwin, WS
    Prince, JL
    INFORMATION PROCESSING IN MEDICAL IMAGING, 1997, 1230 : 313 - 326
  • [47] Myocardial motion analysis based on an optical flow method using tagged MR images
    Tabata D.
    Isoda H.
    Kato K.
    Matsubara H.
    Kosugi T.
    Kosugi T.
    Terada M.
    Fukuyama A.
    Komori Y.
    Naganawa S.
    Radiological Physics and Technology, 2018, 11 (2) : 202 - 211
  • [48] A 3-D model-based registration approach for the PET, MR and MCG cardiac data fusion
    Mäkelä, T
    Pham, QC
    Clarysee, P
    Nenonen, J
    Lötjönen, J
    Sipilä, O
    Hänninen, H
    Lauerma, K
    Knuti, J
    Katila, T
    Magnin, IE
    MEDICAL IMAGE ANALYSIS, 2003, 7 (03) : 377 - 389
  • [49] Segmentation and analysis of 3D cardiac motion from tagged MRI images
    Metaxas, DN
    Axel, L
    Hu, ZH
    Montillo, A
    Park, K
    Qian, Z
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 122 - 125
  • [50] Fully automatic nonrigid registration-based local motion estimation for motion-corrected iterative cardiac CT reconstruction
    Isola, Alfonso A.
    Grass, Michael
    Niessen, Wiro J.
    MEDICAL PHYSICS, 2010, 37 (03) : 1093 - 1109