Experimental study on natural circulation flow instability in parallel boiling channels under low pressure

被引:24
作者
Cheng, Kun [1 ]
Meng, Tao [1 ]
Tan, Sichao [1 ]
Liu, Zheng [1 ]
机构
[1] Harbin Engn Univ, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin 150001, Heilongjiang, Peoples R China
基金
国家重点研发计划;
关键词
Rod bundle; Parallel boiling channels; Asymmetric heating; Flow instability; Natural circulation; DENSITY WAVE OSCILLATIONS; WATER-REACTORS; START-UP; DROP OSCILLATIONS; THERMOHYDRAULICS; MECHANISM; LOOP; BWR;
D O I
10.1016/j.ijheatmasstransfer.2018.12.085
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-phase flow instabilities in parallel boiling channels under natural circulation condition were experimentally studied at low pressure (0.2-0.6 MPa). The parallel boiling channels composed of two different form channels, namely a 3 x 3 rod bundle channel and a tube channel, were used as the testing section. In the present experiment, the flow oscillation behaviors can be classified into three typical modes based on their frequency spectrum characteristics: (1) small amplitude out-of-phase flow instability induced by the type-1 density wave oscillations in parallel boiling channels, (2) large amplitude out-of-phase flow instability with reversal flow induced by the occurrence of geysering in tube channel and (3) a kind of compound flow instability superposed by geysering and natural circulation instability. The influence of thermal hydraulic parameters on the evolution process of above three flow instabilities were analyzed. The marginal stability boundaries presented by the subcooling number (N-sub) and phase change number (N-pch) at different system pressures are obtained and all unstable flow occurs in the negative region of the outlet equilibrium quality in the present experiment. Besides, the effects of asymmetric heating between two parallel channels on NC flow instability were also studied. The asymmetric heating can change the NC flow distribution in parallel boiling channels and reduce the system stability. The occurrence of out-phase oscillations in parallel channels can be suppressed with the increasing of heating power asymmetry. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1126 / 1136
页数:11
相关论文
共 50 条
  • [1] Study on flow instability in natural circulation loop with parallel channels under moving condition
    Tian, Wenxi
    Gui, Minyang
    Wu, Di
    Chen, Ronghua
    Su, G. H.
    Qiu, Suizheng
    NUCLEAR ENGINEERING AND DESIGN, 2021, 379
  • [2] SIMULATION OF OSCILLATIONS IN BOILING FLOW IN A NATURAL CIRCULATION EVAPORATOR
    Paruya, S.
    Bhattacharya, P.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2009, 196 (03) : 362 - 390
  • [3] Experimental study on distribution regions of flow instability and boiling crisis in parallel twin rectangular channels under high pressure
    Tang Y.
    Chen B.
    Xiong W.
    Huang Y.
    Xu J.
    Hedongli Gongcheng/Nuclear Power Engineering, 2016, 37 (02): : 60 - 64
  • [4] Experimental Research of flow instability onset conditions in a natural circulation system with subcooled boiling
    Pan Liang-ming
    Li Jia
    Chen De-qi
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 4, 2014,
  • [5] Experimental study on Ledinegg flow instability of two-phase natural circulation in narrow rectangular channels at low pressure
    Qi, Shi
    Zhou, Tao
    Li, Bing
    Shahzad, Muhammad Ali
    Zou, Yaxiong
    Huang, Yan-Ping
    PROGRESS IN NUCLEAR ENERGY, 2017, 98 : 321 - 328
  • [6] An experimental investigation of flow boiling instability in a natural circulation loop
    Chen, Xianbing
    Gao, Puzhen
    Tan, Sichao
    Yu, Zhiting
    Chen, Chong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 1125 - 1134
  • [7] An experimental investigation of flow reversal under natural circulation flow boiling
    Chen X.
    Gao P.
    Wang Q.
    Wang Z.
    Huang Y.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2019, 40 (09): : 1589 - 1594
  • [8] Experimental Investigation on Characteristics of Boiling Two-Phase-Flow Instability in a Parallel-Multichannel Natural-Circulation System
    Singh, Sapna
    Nayak, A. K.
    Aparna, J.
    NUCLEAR SCIENCE AND ENGINEERING, 2016, 184 (02) : 263 - 279
  • [9] Influence of an insert on low-pressure natural circulation flow instability
    Cheng J.
    Cao X.
    Yu D.
    Han J.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2020, 41 (04): : 525 - 529
  • [10] Experimental investigation on the flow instability behavior of a multi-channel boiling natural circulation loop at low-pressures
    Jain, Vikas
    Nayak, A. K.
    Vijayan, P. K.
    Saha, D.
    Sinha, R. K.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (06) : 776 - 787