Acoustic emission monitoring and finite element analysis of debonding in fiber-reinforced polymer rebar reinforced concrete

被引:55
作者
Li, Weijie [1 ,2 ]
Ho, Siu Chun Michael [1 ]
Patil, Devendra [1 ]
Song, Gangbing [1 ,2 ]
机构
[1] Univ Houston, Dept Mech Engn, Houston, TX 77204 USA
[2] Dalian Univ Technol, Sch Civil Engn, Dalian, Peoples R China
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2017年 / 16卷 / 06期
关键词
Acoustic emission; fiber-reinforced polymer; reinforced concrete; debonding; finite element analysis; FRACTURE MECHANISMS; CLASSIFICATION; IDENTIFICATION; COMPOSITES; CORROSION;
D O I
10.1177/1475921716678922
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The acoustic emission technique is widely used for mechanical diagnostics and damage characterization in reinforced concrete structures. This article experimentally investigated the feasibility of debonding characterization in fiber-reinforced polymer rebar reinforced concrete using acoustic emission technique. To this end, carbon-fiber-reinforced polymer rebar reinforced concrete specimens were prepared and they were subjected to pullout tests to study the interfacial debonding between concrete and reinforcement. Test results showed that the debonding failure between concrete and reinforcement was characterized by the total peeling off of the helical wrapping layer of the carbon-fiber-reinforced polymer reinforcement. The response of acoustic emission activity was analyzed by descriptive parameters, such as cumulative acoustic emission hits, amplitude, and peak frequency. The evolution of debonding failure is thus characterized by these acoustic emission parameters. The results demonstrated a clear correlation between the damage evolution of carbon-fiber-reinforced polymer rebar pullout and the acoustic emission parameters. In addition, finite element analysis was adopted to study the stress field during the pullout of the reinforcement. The simulation results agreed well with the experimental investigations.
引用
收藏
页码:674 / 681
页数:8
相关论文
共 23 条
[1]   Classification of cracking mode in concrete by acoustic emission parameters [J].
Aggelis, Dimitrios G. .
MECHANICS RESEARCH COMMUNICATIONS, 2011, 38 (03) :153-157
[2]   Classification of acoustic emission data from buckling test of carbon fibre panel using unsupervised clustering techniques [J].
Al-Jumaili, Safaa Kh ;
Holford, Karen M. ;
Eaton, Mark J. ;
McCrory, John P. ;
Pearson, Matthew R. ;
Pullin, Rhys .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2015, 14 (03) :241-251
[3]  
[Anonymous], 2015, ACI COMMITTEE 440 4
[4]   Experimental study of bond behaviour between concrete and FRP bars using a pull-out test [J].
Baena, Marta ;
Torres, Lluis ;
Turon, Albert ;
Barris, Cristina .
COMPOSITES PART B-ENGINEERING, 2009, 40 (08) :784-797
[5]   Advanced structural health monitoring of concrete structures with the aid of acoustic emission [J].
Behnia, Arash ;
Chai, Hwa Kian ;
Shiotani, Tomoki .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 65 :282-302
[6]   Identification of corrosion mechanisms by univariate and multivariate statistical analysis during long term acoustic emission monitoring on a pre-stressed concrete beam [J].
Calabrese, L. ;
Campanella, G. ;
Proverbio, E. .
CORROSION SCIENCE, 2013, 73 :161-171
[7]   Modeling the pullout behavior of fiber reinforced polymer bars from concrete [J].
Chang, Xu ;
Yue, Gaowei ;
Lin, Haixiao ;
Tang, Chunan .
CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (04) :431-437
[8]   CRACK IDENTIFICATION IN REINFORCED CONCRETE BEAMS USING ANSYS SOFTWARE [J].
Dahmani, L. ;
Khennane, A. ;
Kaci, S. .
STRENGTH OF MATERIALS, 2010, 42 (02) :232-240
[9]   Modeling and characterization of fiber-reinforced plastic honeycomb sandwich panels for highway bridge applications [J].
Davalos, JF ;
Qiao, PZ ;
Xu, XF ;
Robinson, J ;
Barth, KE .
COMPOSITE STRUCTURES, 2001, 52 (3-4) :441-452
[10]   Real-time frequency determination of acoustic emission for different fracture mechanisms in carbon epoxy composites [J].
deGroot, PJ ;
Wijnen, PAM ;
Janssen, RBF .
COMPOSITES SCIENCE AND TECHNOLOGY, 1995, 55 (04) :405-412