A dual modality phantom for cone beam CT and ultrasound image fusion in prostate implant

被引:4
作者
Ng, Angela [2 ]
Beiki-Ardakan, Akbar [2 ]
Tong, Shidong [3 ]
Moseley, Douglas [2 ]
Siewerdsen, Jeffrey [4 ]
Jaffray, David [2 ]
Yeung, Ivan W. T. [1 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON MG5 2M9, Canada
[2] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[3] Penn State Canc Inst, Dept Radiat Oncol, Hershey, PA 17033 USA
[4] Univ Toronto, Toronto, ON M5G 2M9, Canada
关键词
image fusion; cone beam CT; prostate brachytherapy; transrectal ultrasound;
D O I
10.1118/1.2898189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In transrectal ultrasound (TRUS) guided prostate seed brachytherapy, TRUS provides good delineation of the prostate while x-ray imaging, e.g., C-arm, gives excellent contrast for seed localization. With the recent availability of cone beam CT (CBCT) technology, the combination of the two imaging modalities may provide an ideal system for intraoperative dosimetric feedback during implantation. A dual modality phantom made of acrylic and copper wire was designed to measure the accuracy and precision of image coregistration between a C-arm based CBCT and 3D TRUS. The phantom was scanned with TRUS and CBCT under the same setup condition. Successive parallel transverse ultrasound (US) images were acquired through manual stepping of the US probe across the phantom at an increment of 1 mm over 7.5 cm. The CBCT imaging was done with three reconstructed slice thicknesses (0.4, 0.8, and 1.6 mm) as well as at three different tilt angles (0 degrees, 15 degrees, 30 degrees), and the coregistration between CBCT and US images was done using the Variseed system based on four fiducial markers. Fiducial localization error (FLE), fiducial registration error (FRE), and target registration error (TRE) were calculated for all registered image sets. Results showed that FLE were typically less than 0.4 mm, FRE were less than 0.5 mm, and TRE were typically less than 1 mm within the range of operation for prostate implant (i.e., < 6 cm to surface of US probe). An analysis of variance test showed no significant difference in TRE for the CBCT-US fusion among the three slice thicknesses (p=0.37). As a comparison, the experiment was repeated with a US-conventional CT scanner combination. No significant difference in TRE was noted between the US-conventional CT fusion and that for all three CBCT image slice thicknesses (p=0.21). CBCT imaging was also performed at three different C-arm tilt angles of 0 degrees, 15 degrees, and 30 degrees and reconstructed at a slice thickness of 0.8 mm. There is no significant difference in TRE between 0 degrees and 15 degrees (p=0.191) as well as between 0 degrees and 30 degrees (p=0.275), which suggests that the C-arm may be tilted intraoperatively to acquire CBCT images without compromising the quality of image fusion. The results conclude a high degree of accuracy and precision for the CBCT-TRUS fusion, which could be useful toward achieving real time intraoperative dosimetry in prostate brachytherapy. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:2062 / 2071
页数:10
相关论文
共 25 条
  • [1] Dosimetric impact of the variation of the prostate volume and shape between pretreatment planning and treatment procedure
    Beaulieu, L
    Aubin, S
    Taschereau, R
    Pouliot, J
    Vigneault, E
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (01): : 215 - 221
  • [2] Pressure dependence of the sound velocity in distilled water
    Belogol'skii, VA
    Sekoyan, SS
    Samorukova, LM
    Stefanov, SR
    Levtsov, VI
    [J]. MEASUREMENT TECHNIQUES, 1999, 42 (04) : 406 - 413
  • [3] A clinical method for real-time dosimetric guidance of transperineal 125I prostate implants using interventional magnetic resonance imaging
    Cormack, RA
    Kooy, H
    Tempany, CM
    D'Amico, AV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (01): : 207 - 214
  • [4] DALY MJ, IN PRESS MED PHYS
  • [5] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [6] The distribution of target registration error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) : 917 - 927
  • [7] Computing intraoperative dosimetry for prostate brachytherapy using TRUS and fluoroscopy
    French, D
    Morris, J
    Keyes, M
    Goksel, O
    Salcudean, S
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (10) : 1262 - 1272
  • [8] Ultrasonography and fluoroscopic fusion for prostate brachytherapy dosimetry
    Gong, LX
    Cho, PS
    Han, BH
    Wallner, KE
    Sutlief, SG
    Pathak, SD
    Haynor, DR
    Kim, YM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (05): : 1322 - 1330
  • [9] Grado G L, 2000, Tech Urol, V6, P157
  • [10] International Commission on Radiation Units and Measurements, 1998, ICRU PUBL