共 4 条
Conceptual design of the W7-X port liners
被引:0
作者:
Stadler, Reinhold J.
[1
]
Peacock, A.
[1
]
Boscary, J.
[1
]
Mendelevitch, B.
[1
]
Scholz, P.
[2
]
Schubert, W.
[1
]
机构:
[1] Max Planck Inst Plasma Phys, D-85748 Garching, Germany
[2] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
关键词:
Stellarator;
Wendelstein;
7-X;
In-vessel components;
First wall;
Port liner;
D O I:
10.1016/j.fusengdes.2016.04.046
中图分类号:
TL [原子能技术];
O571 [原子核物理学];
学科分类号:
0827 ;
082701 ;
摘要:
The experimental stellarator Wendelstein 7-X has a large variety of ports for plasma diagnostics. For the steady-state operation with 10 MW input power and a plasma pulse length of up to 30 min, 101 diagnostics ports need to be shielded with actively cooled port liners made of stainless steel. A total of 41 variants of port liners taking into account the various port geometries and the interfaces with different types of diagnostics have to be installed. Before starting the production, different concepts have been studied. Five full-scale demonstrators and three different technologies representative of the port liner variety have been designed and are being produced. Results of this fabrication will serve as a basis for the procurement of the 101 port liners. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:492 / 496
页数:5
相关论文