Evaluation of optimization methods for intensity-based 2D-3D registration in x-ray guided interventions

被引:21
作者
van der Bom, I. M. J. [1 ]
Klein, S. [2 ]
Staring, M. [3 ]
Homan, R. [4 ]
Bartels, L. W. [5 ]
Pluim, J. P. W. [5 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01605 USA
[2] Erasmus MC, Dept Radiol & Med Informat, Biomed Imaging Grp Rotterdam, Rotterdam, Netherlands
[3] Leiden Univ, Dept Radiol, Ctr Med, Div Image Proc, Leiden, Netherlands
[4] Philips Healthcare, X ray Predev, Best, Netherlands
[5] Univ Utrecht, Dept Radiol, Image Sci Inst, Ctr Med, Utrecht, Netherlands
来源
MEDICAL IMAGING 2011: IMAGE PROCESSING | 2011年 / 7962卷
关键词
2D-3D registration; x-ray guided procedures; optimization; MEDICAL IMAGE REGISTRATION; ALGORITHM; CT;
D O I
10.1117/12.877655
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The advantage of 2D-3D image registration methods versus direct image-to-patient registration, is that these methods generally do not require user interaction (such as manual annotations), additional machinery or additional acquisition of 3D data. A variety of intensity-based similarity measures has been proposed and evaluated for different applications. These studies showed that the registration accuracy and capture range are influenced by the choice of similarity measure. However, the influence of the optimization method on intensity-based 2D-3D image registration has not been investigated. We have compared the registration performance of seven optimization methods in combination with three similarity measures: gradient difference, gradient correlation, and pattern intensity. Optimization methods included in this study were: regular step gradient descent, Nelder-Mead, Powell-Brent, Quasi-Newton, nonlinear conjugate gradient, simultaneous perturbation stochastic approximation, and evolution strategy. Registration experiments were performed on multiple patient data sets that were obtained during cerebral interventions. Various component combinations were evaluated on registration accuracy, capture range, and registration time. The results showed that for the same similarity measure, different registration accuracies and capture ranges were obtained when different optimization methods were used. For gradient difference, largest capture ranges were obtained with Powell-Brent and simultaneous perturbation stochastic approximation. Gradient correlation and pattern intensity had the largest capture ranges in combination with Powell-Brent, Nelder-Mead, nonlinear conjugate gradient, and Quasi-Newton. Average registration time, expressed in the number of DRRs required for convergence, was the lowest for Powell-Brent. Based on these results, we conclude that Powell-Brent is a reliable optimization method for intensity-based 2D-3D registration of x-ray images to CBCT, regardless of the similarity measure used.
引用
收藏
页数:15
相关论文
共 25 条
[1]  
[Anonymous], 1999, SPRINGER SCI
[2]  
[Anonymous], 2007, Numerical Recipes
[3]  
Arnold DV, 2002, IEEE T EVOLUT COMPUT, V6, P30, DOI [10.1109/4235.985690, 10.1023/A:1015059928466]
[4]   A faster method for 3D/2D medical image registration - a simulation study [J].
Birkfellner, W ;
Wirth, J ;
Burgstaller, W ;
Baumann, B ;
Staedele, H ;
Hammer, B ;
Gellrich, NC ;
Jacob, AL ;
Regazzoni, P ;
Messmer, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (16) :2665-2679
[5]   A family of hybrid conjugate gradient methods for unconstrained optimization [J].
Dai, YH .
MATHEMATICS OF COMPUTATION, 2003, 72 (243) :1317-1328
[6]   An efficient hybrid conjugate gradient method for unconstrained optimization [J].
Dai, YH ;
Yuan, Y .
ANNALS OF OPERATIONS RESEARCH, 2001, 103 (1-4) :33-47
[7]   Completely derandomized self-adaptation in evolution strategies [J].
Hansen, N ;
Ostermeier, A .
EVOLUTIONARY COMPUTATION, 2001, 9 (02) :159-195
[8]   METHODS OF CONJUGATE GRADIENTS FOR SOLVING LINEAR SYSTEMS [J].
HESTENES, MR ;
STIEFEL, E .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1952, 49 (06) :409-436
[9]   Intensity-based 2-D-3-D registration of cerebral angiograms [J].
Hipwell, JH ;
Penney, GP ;
McLaughlin, RA ;
Rhode, K ;
Summers, P ;
Cox, TC ;
Byrne, JV ;
Noble, JA ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) :1417-1426
[10]   Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy [J].
Khamene, A ;
Bloch, P ;
Wein, W ;
Svatos, M ;
Sauer, F .
MEDICAL IMAGE ANALYSIS, 2006, 10 (01) :96-112