Comparison of EEG Approximate Entropy and Complexity Measures of Depth of Anaesthesia During Inhalational General Anaesthesia

被引:20
作者
Fan, Shou-Zen [2 ]
Yeh, Jia-Rong [1 ,3 ]
Chen, Bo-Cun [1 ]
Shieh, Jiann-Shing [1 ,3 ]
机构
[1] Yuan Ze Univ, Dept Mech Engn, Tao Yuan 320, Taiwan
[2] Natl Taiwan Univ, Coll Med, Dept Anesthesiol, Taipei 106, Taiwan
[3] Natl Cent Univ, Ctr Dynam Biomarkers & Translat Med, Tao Yuan 320, Taiwan
关键词
Approximate entropy (ApEn); Lempel-Ziv complexity (LZC); Electroencephalogram (EEG); Bispectral index (BIS); HEART-RATE-VARIABILITY; BISPECTRAL INDEX; POWER SPECTRUM; PROPOFOL; AWARENESS; MONITOR; SYSTEM; ELECTROENCEPHALOGRAM; CONSCIOUSNESS;
D O I
10.5405/jmbe.820
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Approximate entropy (ApEn) and Lempel-Ziv complexity (LZC), which are nonlinear quantification methods of the regularity of electroencephalogram (EEG) signals, have recently been proposed as measures of the depth of anaesthesia. The present study compares these two methods to two traditional linear methods, namely 95% spectral edge frequency (SEF95) and median edge frequency (MEF), and a commercial method, bispectral index (BIS), in pre-anaesthesia, maintenance, and recovery stages. Twenty-three patients (12 males and 11 females) with inhalational anaesthesia were enrolled. The BIS, SEF95, and MEF data of the anaesthetized subjects are collected using a BIS monitor. Raw EEG data are transmitted to a computer for off-line analysis to obtain ApEn and LZC values. The ApEn, LZC, SEF95, and MEF values are converted to a 0-100 range for comparison with BIS. There are significant differences (P < 0.05) in th results between the pre-anaesthesia and maintenance stages and between the recovery and maintenance stages obtained from BIS, ApEn, and LZC, which indicates that the three measures can differentiate the state of anaesthetia in a patient. There are no differences (P > 0.05) in the ApEn and LZC values between the pre-anaesthesia and recovery stages, indicating that ApEn and LZC show the increases in values from maintenance phase to recovery phase similar to the reductions in values from pre-anaesthesia phase to maintenance phase. The changes of ApEn and LZC in recovery stage are significantly larger than that exhibited by BIS. BIS shows a statistically reduced level from the pre-anaesthesia to the recovery stage, whereas ApEn and LZC show no difference. This indicates that ApEn and LZC respond more rapidly to recovery than does BIS. LZC and ApEn perform more sensitively than BIS in detecting the recovery of consciousness from non-responding to responding. Moreover, traditional assessments SEF95 and MEF perform poorly compared to BIS.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 43 条
[1]   Anesthesia awareness and the bispectral index [J].
Avidan, Michael S. ;
Zhang, Lini ;
Burnside, Beth A. ;
Finkel, Kevin J. ;
Searleman, Adam C. ;
Selvidge, Jacqueline A. ;
Saager, Leif ;
Turner, Michelle S. ;
Rao, Srikar ;
Bottros, Michael ;
Hantler, Charles ;
Jacobsohn, Eric ;
Evers, Alex S. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (11) :1097-1108
[2]   Correlation of approximate entropy, bispectral index, and spectral edge frequency 95 (SEF95) with clinical signs of "anesthetic depth" during coadministration of propofol and remifentanil [J].
Bruhn, J ;
Bouillon, TW ;
Radulescu, L ;
Hoeft, A ;
Bertaccini, E ;
Shafer, SL .
ANESTHESIOLOGY, 2003, 98 (03) :621-627
[3]   Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia [J].
Bruhn, J ;
Röpcke, H ;
Hoeft, A .
ANESTHESIOLOGY, 2000, 92 (03) :715-726
[4]   Noise and poise: Enhancement of postural complexity in the elderly with a stochastic-resonance-based therapy [J].
Costa, M. ;
Priplata, A. A. ;
Lipsitz, L. A. ;
Wu, Z. ;
Huang, N. E. ;
Goldberger, A. L. ;
Peng, C. K. .
EPL, 2007, 77 (06)
[5]   The Narcotrend™ monitor and the electroencephalogram in propofol-induced sedation [J].
Doenicke, Alfred W. ;
Kugler, Johann ;
Kochs, Eberhard ;
Rau, Jeus ;
Mueckter, Haraed ;
Hoernecke, Rainer ;
Conzen, Peter ;
Bromber, Harry ;
Schneider, Gerhard .
ANESTHESIA AND ANALGESIA, 2007, 105 (04) :982-992
[6]   Behaviour of entropy/complexity measures of the electroencephalogram during propofol-induced sedation - Dose-dependent effects of remifentanil [J].
Ferenets, Rain ;
Vanluchene, Ann ;
Lipping, Tarmo ;
Heyse, Bjorn ;
Struys, Michel M. R. F. .
ANESTHESIOLOGY, 2007, 106 (04) :696-706
[7]   Comparison of entropy and complexity measures for the assessment of depth of sedation [J].
Ferenets, Rain ;
Lipping, Tarmo ;
Anier, Andres ;
Jantti, Ville ;
Melto, Sari ;
Hovilehto, Seppo .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (06) :1067-1077
[8]   Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness [J].
Gajraj, RJ ;
Doi, M ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) :46-52
[9]   HEART-RATE-VARIABILITY DURING PROPOFOL ANESTHESIA [J].
GALLETLY, DC ;
BUCKLEY, DHF ;
ROBINSON, BJ ;
CORFIATIS, T .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (02) :219-220
[10]  
Glantz S. A., 2002, Primer of Biostatistics