Nanostructured Gold Microelectrode Array for Ultrasensitive Detection of Heavy Metal Contamination

被引:42
作者
Podesva, Pavel [1 ]
Gablech, Imrich [2 ]
Neuzil, Pavel [1 ,2 ]
机构
[1] Northwestern Polytech Univ, Sch Mech Engn, Dept Microsyst Engn, 127 West Youyi Rd, Xian 710072, Shaanxi, Peoples R China
[2] Brno Univ Technol, Cent European Inst Technol, Purkynova 656-123, Brno 61200, Czech Republic
关键词
ANODIC-STRIPPING VOLTAMMETRY; ELECTROCHEMICAL DETECTION; NANOELECTRODE ENSEMBLES; MODIFIED ELECTRODES; OXYGEN REDUCTION; FILM ELECTRODE; NATURAL-WATERS; BEHAVIOR; MERCURY; COPPER;
D O I
10.1021/acs.analchem.7b03725
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Availability of potable water is a problem especially in developing countries as their water sources are often contaminated biologically as well as by heavy metals. Electrochemical methods are suitable for field application to monitor heavy metal contents. Noble metal electrodes with large surface areas are the subject of intensive development as they can yield an improved signal-to-noise ratio, enhanced sensitivity, and lower limits of detection (LOD). Here, we present a nanostructured Au microelectrode array subseqUently modified by selective electrodeposition in lithographically defined circles within a partially cross-linked gelatin layer. This method increased its surface area by a factor of approximate to 1440 in comparison with an original lithography -based prepared array. The Au surface properties can be tailored by a degree of gelatin layer cross-linking. We used this array for an ultrasensitive detection of the As3+ ions content by stripping voltammetry achieving LOD of 0.0212 parts per billion (signal-to-noise ratio = 3.3), 470X below the content limit recommended by the World Health Organization for potable water. These nanostructtired arrays were used to detect ions of other metals such as Cr, Cd, Hg, Cu, and Sb. In combination with a portable electrochemical device, we can envision an ultrasensitive heavy metal detection system for field application to monitor heavy metal contamination.
引用
收藏
页码:1161 / 1167
页数:7
相关论文
共 40 条
[1]   Constant current cathodic stripping potentiometric determination of arsenic on a mercury film electrode in the presence of copper ions [J].
Adeloju, SB ;
Young, TM ;
Jagner, D ;
Batley, GE .
ANALYTICA CHIMICA ACTA, 1999, 381 (2-3) :207-213
[2]  
[Anonymous], 2018, Guidelines for Drinking Water Quality
[3]   Multiple voltammetric waves for reductive desorption of cysteine and 4-mercaptobenzoic acid monolayers self-assembled on gold substrates [J].
Arihara, K ;
Ariga, T ;
Takashima, N ;
Arihara, K ;
Okajima, T ;
Kitamura, F ;
Tokuda, K ;
Ohsaka, T .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2003, 5 (17) :3758-3761
[4]   The Nanolithography Toolbox [J].
Balram, Krishna C. ;
Westly, Daron A. ;
Davanco, Marcelo ;
Grutter, Karen E. ;
Li, Qing ;
Michels, Thomas ;
Ray, Christopher H. ;
Yu, Liya ;
Kasica, Richard J. ;
Wallin, Christopher B. ;
Gilbert, Ian J. ;
Bryce, Brian A. ;
Simelgor, Gregory ;
Topolancik, Juraj ;
Lobontiu, Nicolae ;
Liu, Yuxiang ;
Neuzil, Pavel ;
Svatos, Vojtech ;
Dill, Kristen A. ;
Bertrand, Neal A. ;
Metzler, Meredith G. ;
Lopez, Gerald ;
Czaplewski, David A. ;
Ocola, Leonidas ;
Srinivasan, Kartik A. ;
Stavis, Samuel M. ;
Aksyuk, Vladimir A. ;
Liddle, J. Alexander ;
Krylov, Slava ;
Ilic, B. Robert .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2016, 121 :464-475
[5]  
Bari G.A., 2010, Modern electroplating, V5th
[6]  
Barra CM, 2001, ELECTROANAL, V13, P1098, DOI 10.1002/1521-4109(200109)13:13<1098::AID-ELAN1098>3.0.CO
[7]  
2-I
[8]  
Collinson M. M., 2013, ISRN Analytical Chemistry, V2013
[9]   Anodic stripping voltammetry of arsenic(III) using gold nanoparticle-modified electrodes [J].
Dai, X ;
Nekrassova, O ;
Hyde, ME ;
Compton, RG .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5924-5929
[10]   DETERMINATION OF TOTAL ARSENIC AT NANOGRAM LEVEL BY HIGH-SPEED ANODIC-STRIPPING VOLTAMMETRY [J].
DAVIS, PH ;
DULUDE, GR ;
GRIFFIN, RM ;
MATSON, WR ;
ZINK, EW .
ANALYTICAL CHEMISTRY, 1978, 50 (01) :137-143