The Comet Assay: Automated Imaging Methods for Improved Analysis and Reproducibility

被引:28
作者
Braafladt, Signe [1 ]
Reipa, Vytas [1 ]
Atha, Donald H. [1 ]
机构
[1] NIST, Biosyst & Biomat Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1038/srep32162
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Sources of variability in the comet assay include variations in the protocol used to process the cells, the microscope imaging system and the software used in the computerized analysis of the images. Here we focus on the effect of variations in the microscope imaging system and software analysis using fixed preparations of cells and a single cell processing protocol. To determine the effect of the microscope imaging and analysis on the measured percentage of damaged DNA (% DNA in tail), we used preparations of mammalian cells treated with etoposide or electrochemically induced DNA damage conditions and varied the settings of the automated microscope, camera, and commercial image analysis software. Manual image analysis revealed measurement variations in percent DNA in tail as high as 40% due to microscope focus, camera exposure time and the software image intensity threshold level. Automated image analysis reduced these variations as much as three-fold, but only within a narrow range of focus and exposure settings. The magnitude of variation, observed using both analysis methods, was highly dependent on the overall extent of DNA damage in the particular sample. Mitigating these sources of variability with optimal instrument settings facilitates an accurate evaluation of cell biological variability.
引用
收藏
页数:9
相关论文
共 14 条
[1]   The essential comet assay: a comprehensive guide to measuring DNA damage and repair [J].
Azqueta, Amaya ;
Collins, Andrew R. .
ARCHIVES OF TOXICOLOGY, 2013, 87 (06) :949-968
[2]   Titanium dioxide nanoparticles induce oxidative stress and DNA-adduct formation but not DNA-breakage in human lung cells [J].
Bhattacharya, Kunal ;
Davoren, Maria ;
Boertz, Jens ;
Schins, Roel P. F. ;
Hoffmann, Eik ;
Dopp, Elke .
PARTICLE AND FIBRE TOXICOLOGY, 2009, 6
[3]   High through put sample processing and automated scoring [J].
Brunborg, Gunnar ;
Jackson, Petra ;
Shaposhnikov, Sergey ;
Dahl, Hildegunn ;
Azqueta, Amaya ;
Collins, Andrew R. ;
Gutzkow, Kristine B. .
FRONTIERS IN GENETICS, 2014, 5
[4]   Controlling variation in the comet assay [J].
Collins, Andrew R. ;
El Yamani, Naouale ;
Lorenzo, Yolanda ;
Shaposhnikov, Sergey ;
Brunborg, Gunnar ;
Azqueta, Amaya .
FRONTIERS IN GENETICS, 2014, 5
[5]   Comet assay: a reliable tool for the assessment of DNA damage in different models [J].
Dhawan, Alok ;
Bajpayee, Mahima ;
Parmar, Devendra .
CELL BIOLOGY AND TOXICOLOGY, 2009, 25 (01) :5-32
[6]   THE COMET ASSAY - A COMPREHENSIVE REVIEW [J].
FAIRBAIRN, DW ;
OLIVE, PL ;
ONEILL, KL .
MUTATION RESEARCH-REVIEWS IN GENETIC TOXICOLOGY, 1995, 339 (01) :37-59
[7]   An Automated Protocol for Performance Benchmarking a Widefield Fluorescence Microscope [J].
Halter, Michael ;
Bier, Elianna ;
DeRose, Paul C. ;
Cooksey, Gregory A. ;
Choquette, Steven J. ;
Plant, Anne L. ;
Elliott, John T. .
CYTOMETRY PART A, 2014, 85A (11) :978-985
[8]   Etoposide: Four decades of development of a topoisomerase II inhibitor [J].
Hande, KR .
EUROPEAN JOURNAL OF CANCER, 1998, 34 (10) :1514-1521
[9]  
I. S. O. Technical Report, 2014, 161972014 ISOTR
[10]   The comet assay in nanotoxicology research [J].
Karlsson, Hanna L. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) :651-666