Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector

被引:15
作者
Babicz, M. [1 ,2 ]
Bagby, L. [3 ]
Baibussinov, B. [4 ,5 ]
Bellini, V [6 ,7 ]
Bonesini, M. [8 ,9 ]
Braggiotti, A. [4 ,5 ,10 ]
Centro, S. [4 ,5 ]
Cervi, T. [11 ,12 ]
Cocco, A. G. [13 ,14 ]
Falcone, A. [11 ,12 ,15 ]
Farnese, C. [4 ,5 ]
Fava, A. [3 ,4 ,5 ]
Fichera, F. [6 ,7 ]
Gibin, D. [4 ,5 ]
Guglielmi, A. [4 ,5 ]
Kose, U. [2 ]
Mazza, R. [8 ,9 ]
Menegolli, A. [11 ,12 ]
Meng, G. [4 ,5 ]
Montanari, C. [11 ,12 ]
Nessi, M. [2 ]
Picchi, P. [11 ,12 ]
Pietropaolo, F. [2 ,4 ,5 ]
Prata, M. C. [11 ,12 ]
Rappoldi, A. [11 ,12 ]
Raselli, G. L. [11 ,12 ]
Rossella, M. [11 ,12 ]
Rubbia, C. [2 ,16 ,17 ]
Sala, P. [2 ]
Scaramelli, A. [11 ,12 ]
Sergiampietri, F. [18 ]
Spanu, M. [11 ,12 ,19 ]
Torti, M. [8 ,9 ]
Tortorici, F. [6 ,7 ]
Varanini, F. [4 ,5 ]
Ventura, S. [4 ,5 ]
Vignoli, C. [17 ]
Zani, A. [2 ]
机构
[1] PAN, Inst Nucl Phys, Krakow, Poland
[2] CERN, Geneva, Switzerland
[3] Fermi Natl Lab, Batavia, IL USA
[4] Univ Padua, Padua, Italy
[5] INFN, Padua, Italy
[6] Univ Catania, Catania, Italy
[7] INFN, Catania, Italy
[8] Univ Milano Bicocca, Milan, Italy
[9] INFN, Milan, Italy
[10] CNR, Padua, Italy
[11] Univ Pavia, Pavia, Italy
[12] INFN, Pavia, Italy
[13] Univ Napoli, Naples, Italy
[14] INFN, Naples, Italy
[15] Univ Texas Arlington, Arlington, TX 76019 USA
[16] Gran Sasso Sci Inst, Laquila, Italy
[17] INFN, Lab Nazl Gran Sasso, Assergi, Italy
[18] INFN, Pisa, Italy
[19] Brookhaven Natl Lab, Upton, NY 11973 USA
来源
JOURNAL OF INSTRUMENTATION | 2018年 / 13卷
关键词
Photon detectors for UV; visible and IR photons (vacuum) (photomultipliers; HPDs; others); Noble liquid detectors (scintillation; ionization; double-phase); Time projection chambers;
D O I
10.1088/1748-0221/13/10/P10030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from Hamamatsu and tested at room temperature to evaluate the performance of the devices and their compliance to detect the liquid argon scintillation light in the T600 detector. Furthermore 60 units were also characterized at cryogenic temperature, in liquid argon bath, to evaluate any parameter variation which could affect the scintillation light detection. All the tested PMTs were found to comply with the requirements of ICARUS T600 and a subset of 360 specimens was selected for the final installation in the detector.
引用
收藏
页数:18
相关论文
共 12 条
[1]   Characterization of large area PMTs at cryogenic temperature for rare event physics experiments [J].
Agnes, P. ;
Raselli, G. L. ;
Rossella, M. .
JOURNAL OF INSTRUMENTATION, 2014, 9
[2]  
Akimov D. Yu., 2015, NUCL INSTRUM METH A, V794, P1
[3]   Design, construction and tests of the ICARUS T600 detector [J].
Amerio, S ;
Amoruso, S ;
Antonello, M ;
Aprili, P ;
Armenante, M ;
Arneodo, F ;
Badertscher, A ;
Baiboussinov, B ;
Ceolin, MB ;
Battistoni, G ;
Bekman, B ;
Benetti, P ;
Bernardini, E ;
Bischofberger, M ;
di Tigliole, AB ;
Brunetti, R ;
Bruzzese, R ;
Bueno, A ;
Calligarich, E ;
Campanelli, M ;
Carbonara, F ;
Carpanese, C ;
Cavalli, D ;
Cavanna, F ;
Cennini, P ;
Centro, S ;
Cesana, A ;
Chen, C ;
Chen, D ;
Chen, DB ;
Chen, Y ;
Cid, R ;
Cline, DB ;
Cieslik, K ;
Cocco, AG ;
Corti, D ;
Dai, Z ;
De Vecchi, C ;
Dabrowska, A ;
Di Cicco, A ;
Dolfini, R ;
Ereditato, A ;
Felcini, M ;
Ferella, A ;
Ferrari, A ;
Ferri, F ;
Fiorillo, G ;
Galli, S ;
Gamez, DG ;
Ge, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (03) :329-410
[4]   Characterization of ETL 9357FLA photomultiplier tubes for cryogenic temperature applications [J].
Ankowski, A ;
Antonello, M ;
Aprili, P ;
Arneodo, F ;
Badertscher, A ;
Baiboussinov, B ;
Ceolin, MB ;
Battistoni, G ;
Benetti, P ;
Bischofberger, M ;
di Tigliole, AB ;
Brunetti, R ;
Bucciarelli, G ;
Bueno, A ;
Calligarich, E ;
Carbonara, F ;
Carmona, MC ;
Cavanna, F ;
Cennini, P ;
Centro, S ;
Cesana, A ;
Cline, DB ;
Cieslik, K ;
Cocco, AG ;
Dai, Z ;
De Vecchi, C ;
Dabrowska, A ;
Di Cicco, A ;
Dolfini, R ;
Ereditato, A ;
Ferella, A ;
Ferrari, A ;
Fiorillo, G ;
García-Gamez, D ;
Ge, Y ;
Gibin, D ;
Berzolari, AG ;
Gil-Botella, I ;
Graczyk, K ;
Grandi, L ;
Guglielmi, A ;
Holeczek, J ;
Juszczak, C ;
Kielczewska, D ;
Kisiel, J ;
Kozlowski, T ;
Laffranchi, M ;
Lagoda, J ;
Lisowski, B ;
Lozano, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01) :146-157
[5]  
Babicz M., 2018, NUCL INSTRUM METH A
[6]  
Bonesini M., ARXIV180707123
[7]   Realization of a high vacuum evaporation system for wave-length shifter deposition on photo-detector windows [J].
Bonesini, Maurizio ;
Mazza, Roberto ;
Cervi, Tommaso ;
Menegolli, Alessandro ;
Prata, Marco Cesare ;
Raselli, Gian Luca ;
Rossella, Massimo ;
Spanu, Maura Ninuccia ;
Torti, Marta .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2018, 36 (01)
[8]   Comparison between large area photo-multiplier tubes at cryogenic temperature for neutrino and rare event physics experiments [J].
Falcone, A. ;
Bertoni, R. ;
Boffelli, F. ;
Bonesini, M. ;
Cervi, T. ;
Menegolli, A. ;
Montanari, C. ;
Prata, M. C. ;
Rappoldi, A. ;
Raselli, G. L. ;
Rossella, M. ;
Spanu, M. ;
Torti, M. ;
Zani, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 :55-58
[9]  
Hamamatsu Photonics K. K, 2011, R5912 MOD DAT SHEET
[10]  
Meyer H.O., ARXIV08050771