Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry

被引:79
|
作者
Peng, SX [1 ]
Branch, TM [1 ]
King, SL [1 ]
机构
[1] Procter & Gamble Pharmaceut, Hlth Care Res Ctr, Mason, OH 45040 USA
关键词
D O I
10.1021/ac001036c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated high-throughput liquid-liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC-MS/MS), The LC-MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC-MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids, The complete bioanalytical method, based on the automated LLE and fast gradient LC-IMS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [41] Quantitative determination of odanacatib in human plasma using liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry analysis
    Sun, Li
    Forni, Sabrina
    Schwartz, Michael S.
    Breidinger, Sheila
    Woolf, Eric J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 15 - 23
  • [42] Analysis of 30 synthetic cannabinoids in serum by liquid chromatography-electrospray ionization tandem mass spectrometry after liquid-liquid extraction
    Kneisel, Stefan
    Auwaerter, Volker
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (07): : 825 - 835
  • [43] Liquid chromatography/electrospray tandem mass spectrometry method for the quantitation of fosinoprilat in human serum using automated 96-well solid-phase extraction for sample preparation
    Jemal, M
    Huang, M
    Mao, Y
    Whigan, D
    Schuster, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (12) : 1023 - 1028
  • [44] Analysis of cannabinoids by liquid chromatography— Thermospray mass spectrometry and liquid chromatography— Tandem mass spectrometry
    K. Ndjoko
    J. -L. Wolfender
    K. Hostettmann
    Chromatographia, 1998, 47 : 72 - 76
  • [45] Analysis of hydrazine in drinldng water by isotope dilution gas chromatography/tandem, mass spectrometry with derivatization and liquid-liquid extraction
    Davis, William E., II
    Li, Yongtao
    ANALYTICAL CHEMISTRY, 2008, 80 (14) : 5449 - 5453
  • [46] Development and application of HPLC methods with tandem mass spectrometric detection for the determination of hydrochlorothiazide in human plasma and urine using 96-well liquid-liquid extraction
    Fang, W
    Xie, W
    Hsieh, JYK
    Matuszewski, BK
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (17) : 2681 - 2703
  • [47] Analysis of cannabinoids by liquid chromatography - Thermospray mass spectrometry and liquid chromatography - Tandem mass spectrometry
    Ndjoko, K
    Wolfender, JL
    Hostettmann, K
    CHROMATOGRAPHIA, 1998, 47 (1-2) : 72 - 76
  • [48] Quantitation of 17α-ethinylestradiol in aquatic samples using liquid-liquid phase extraction, dansyl derivatization, and liquid chromatography/positive electrospray tandem mass spectrometry
    Zhang, F
    Bartels, MJ
    Brodeur, JC
    McClymont, EL
    Woodburn, KB
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (22) : 2739 - 2742
  • [49] High-throughput semi-automated 96-well liquid/liquid extraction and liquid chromatography/mass spectrometric analysis of everolimus (RAD 001) and cyclosporin a (CsA) in whole blood
    Brignol, N
    McMahon, LM
    Luo, S
    Tse, FLS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 898 - 907
  • [50] Determination of Eight Coccidiostats in Eggs by Liquid-Liquid Extraction-Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry
    Wang, Bo
    Liu, Jianyu
    Zhao, Xia
    Xie, Kaizhou
    Diao, Zhixiang
    Zhang, Genxi
    Zhang, Tao
    Dai, Guojun
    MOLECULES, 2020, 25 (04):