Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry

被引:79
|
作者
Peng, SX [1 ]
Branch, TM [1 ]
King, SL [1 ]
机构
[1] Procter & Gamble Pharmaceut, Hlth Care Res Ctr, Mason, OH 45040 USA
关键词
D O I
10.1021/ac001036c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated high-throughput liquid-liquid extraction (LLE) methodology has been developed for preparation of biological samples using a 96-well LLE plate and a 96-channel robotic liquid handling workstation. The 96-well LLE plate is made of a 96-well filter plate filled with inert diatomaceous earth particles, allowing continuous and efficient extraction of analytes between the aqueous biological sample and the organic extraction solvent. Two carboxylic acid-based protease inhibitor compounds with high and low levels of plasma protein binding were chosen for the development and application of the automated methodology. The LLE extracts of the plasma samples of the two compounds were analyzed by high-performance liquid chromatography with electrospray (ESI) tandem mass spectrometry (LC-MS/MS), The LC-MS/MS method was developed using a rapid gradient LC separation, followed by sample introduction through an ionspray interface in the negative ion mode and tandem mass spectrometric detection with selected reaction monitoring. In the optimized LLE method, a formate buffer solution was first loaded into a 96-well filter plate packed with inert diatomaceous earth material. Then crude plasma samples and a water-immiscible organic solvent, methyl ethyl ketone, were sequentially added to the LLE plate so that LLE would occur in the interface between the two liquid phases on the surface of individual particles in each well. The organic eluate containing extracted analytes was evaporated and reconstituted for LC-MS/MS analysis. This fully automated LLE methodology avoids several disjointed steps involved in a manual or semiautomated LLE method, leading to significantly reduced sample preparation time, increased sample throughput, and clean sample extracts for improved ESI-MS/MS detection. The automated LLE methodology is universal and can be employed for sample preparation of other biological fluids, The complete bioanalytical method, based on the automated LLE and fast gradient LC-IMS/MS, was validated and successfully applied to the quantitative analysis of protease inhibitors in rat plasma.
引用
收藏
页码:708 / 714
页数:7
相关论文
共 50 条
  • [11] Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid-liquid extraction used as plasma sample preparation techniques for liquid chromatography-tandem mass spectrometry
    Zimmer, D
    Pickard, V
    Czembor, W
    Müller, C
    JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 23 - 35
  • [12] A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma
    Shou, WZ
    Jiang, XY
    Beato, BD
    Weng, ND
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (07) : 466 - 476
  • [13] Automated liquid-liquid extraction based on 96-well plate format in conjunction with ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the quantitation of methoxsalen in human plasma
    Yadav, Manish
    Contractor, Pritesh
    Upadhyay, Vivek
    Gupta, Ajay
    Guttikar, Swati
    Singhal, Puran
    Goswami, Sailendra
    Shrivastav, Pranav S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 167 - 171
  • [14] Development of a rapid method for the determination of glimepiride in human plasma using liquid-liquid extraction based on 96-well format micro-tubes and liquid chromatography/tandem mass spectrometry
    Dotsikas, Y
    Kousoulos, C
    Tsatsou, G
    Loukas, YL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 2055 - 2061
  • [15] Method development for the quantitation of ABT-578 in rabbit artery tissue by 96-well liquid-liquid extraction and liquid chromatography/tandem mass spectrometric detection
    Ji, QC
    Zhang, J
    Rodila, R
    Watson, P
    El-Shourbagy, T
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (19) : 2293 - 2298
  • [16] Determination of suvorexant in human plasma using 96-well liquid-liquid extraction and HPLC with tandem mass spectrometric detection
    Breidinger, S. A.
    Simpson, R. C.
    Mangin, E.
    Woolf, E. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1002 : 254 - 259
  • [17] Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma
    Eerkes, A
    Shou, WZ
    Weng, ND
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) : 917 - 928
  • [18] A 96-well single-pot liquid-liquid extraction, hydrophilic interaction liquid chromatography-mass spectrometry method for the determination of muraglitazar in human plasma
    Xue, Y. -J.
    Liu, Jane
    Unger, Steve
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 979 - 988
  • [19] Determination of digoxin and its metabolites in biological samples by solidphase supported liquid-liquid extraction-liquid chromatography-tandem mass spectrometry
    Yijian, Sun
    Bo, Zou
    Aihua, Wang
    Ruihua, Wang
    Jiayi, L.I.
    Xiaoping, Hou
    Jifen, Wang
    Jing, Chang
    Chinese Journal of Analysis Laboratory, 2023, 42 (05) : 665 - 670
  • [20] Development of a novel 96-well format for liquid-liquid microextraction and its application in the HPLC analysis of biological samples
    Borijihan, Guirong
    Li, Youxin
    Gao, Jianguo
    Bao, James J.
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (9-10) : 1155 - 1161