Remote monitoring of implantable cardioverter-defibrillators Problems and implications using a telemonitoring system

被引:0
作者
Siebermair, J. [1 ]
Clauss, S. [1 ]
Martens, E. [1 ]
Schuessler, F. [1 ]
Oversohl, N. [1 ]
Haserueck, N. [1 ]
Estner, H. L. [1 ]
Kaeaeb, S. [2 ]
Wakili, R. [1 ]
机构
[1] Hosp Ludwig Maximilians Univ Munich LMU, Dept Med 1, D-80336 Munich, Germany
[2] Partner Site Munich Heart Alliance, Deutsch Zentrum Herzkreislaufforsch DZHK, Munich, Germany
关键词
Implantable cardioverter-defibrillator; Home monitoring; Heart failure; Telemedicine; Telemonitoring; HEART-FAILURE; TELEMEDICINE; MANAGEMENT; PACEMAKER; DEVICES; TRIAL; TIME; CARE; ICD;
D O I
10.1007/s00059-014-4080-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The rising number of implantable devices has led to an increase in device-related workload, e.g., regular interrogation follow-up visits. Telemonitoring systems for implantable cardioverter-defibrillators (ICDs) seem to be a promising tool for reducing workload and costs, and they have the potential of optimizing patient care. However, issues such as practical functionality of ICD telemonitoring in daily routine may affect its broad implementation. The objective of this study was to evaluate potential problems during the implementation of a telemonitoring system, Medtronic CareLink (TM) (CL (TM)) with respect to the installation and data transmission process. A total of 159 patients with ICDs who were equipped with the CL (TM) system were evaluated and followed up for 16 months regarding the success rate of the first data transmission via the telemonitoring system. In this cohort, a high rate of nontransmission of 23.9 % was observed after the 16-month follow-up. A detailed interview of these patients (no transmission) revealed that the main reasons for failed transmissions were due to the patients' loss of interest in the concept (approximately 50 %) as well as technical problems (approximately 25 %) with setting up the system. These results indicate that telemonitoring systems bear potential problems and that the evaluation of patient motivation and technical support options seems to play an important role in establishing the functionality of these systems.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 20 条
[1]   Feasibility Evaluation of a Remote Monitoring System for Implantable Cardiac Devices in Japan A Prospective Analysis [J].
Ando, Kenji ;
Koyama, Junjiroh ;
Abe, Yoshihisa ;
Sato, Toshiaki ;
Shoda, Morio ;
Soga, Yoshimitsu ;
Nobuyoshi, Masakiyo ;
Honda, Toshihiro ;
Nakao, Koichi ;
Terata, Ken ;
Kadowaki, Ken ;
Maeda, Akiko ;
Ogawa, Satoshi ;
Manaka, Tetsuyuki ;
Hagiwara, Nobuhisa ;
Doi, Kentaro .
INTERNATIONAL HEART JOURNAL, 2011, 52 (01) :39-43
[2]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[3]   Experience-based guidelines for the implementation of telemedicine services [J].
Brebner, JA ;
Brebner, EM ;
Ruddick-Bracken, H .
JOURNAL OF TELEMEDICINE AND TELECARE, 2005, 11 :3-5
[4]   Determinants of successful telemedicine implementations: a literature study [J].
Broens, Tom H. F. ;
in't Veld, Rianne M. H. A. Huis ;
Vollenbroek-Hutten, Miriam M. R. ;
Hermens, Hermie J. ;
van Halteren, Aart T. ;
Nieuwenhuis, Lambert J. M. .
JOURNAL OF TELEMEDICINE AND TELECARE, 2007, 13 (06) :303-309
[5]   Telemonitoring for patients with chronic heart failure: A systematic review [J].
Chaudhry, Sarwat I. ;
Phillips, Christopher O. ;
Stewart, Simon S. ;
Riegel, Barbara ;
Mattera, Jennifer A. ;
Jerant, Anthony F. ;
Krumholz, Harlan M. .
JOURNAL OF CARDIAC FAILURE, 2007, 13 (01) :56-62
[6]   Telemonitoring in Patients with Heart Failure [J].
Chaudhry, Sarwat I. ;
Mattera, Jennifer A. ;
Curtis, Jeptha P. ;
Spertus, John A. ;
Herrin, Jeph ;
Lin, Zhenqiu ;
Phillips, Christopher O. ;
Hodshon, Beth V. ;
Cooper, Lawton S. ;
Krumholz, Harlan M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (24) :2301-2309
[7]   The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial The Value of Wireless Remote Monitoring With Automatic Clinician Alerts [J].
Crossley, George H. ;
Boyle, Andrew ;
Vitense, Holly ;
Chang, Yanping ;
Mead, R. Hardwin .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (10) :1181-1189
[8]  
European Heart Rhythm Association, 2006, J Am Coll Cardiol, V48, pe247, DOI 10.1016/j.jacc.2006.07.010
[9]   Remote Monitoring Reduces Healthcare Use and Improves Quality of Care in Heart Failure Patients With Implantable Defibrillators The Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) Study [J].
Landolina, Maurizio ;
Perego, Giovanni B. ;
Lunati, Maurizio ;
Curnis, Antonio ;
Guenzati, Giuseppe ;
Vicentini, Alessandro ;
Parati, Gianfranco ;
Borghi, Gabriella ;
Zanaboni, Paolo ;
Valsecchi, Sergio ;
Marzegalli, Maurizio .
CIRCULATION, 2012, 125 (24) :2985-2992
[10]   A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial) [J].
Mabo, Philippe ;
Victor, Frederic ;
Bazin, Patrick ;
Ahres, Said ;
Babuty, Dominique ;
Da Costa, Antoine ;
Binet, Didier ;
Daubert, Jean-Claude .
EUROPEAN HEART JOURNAL, 2012, 33 (09) :1105-1111