3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study

被引:6
|
作者
Chan, Andrew [1 ]
Parent, Eric [2 ]
Mahood, Jim [3 ]
Lou, Edmond [1 ,3 ,4 ]
机构
[1] Univ Alberta, Dept Biomed Engn, 1098 Res Transit Facil, 8308-114 St, Edmonton, AB T6G 2V2, Canada
[2] Univ Alberta, Fac Rehabil Med, Dept Phys Therapy, 2-50 Corbett Hall, Edmonton, AB T6G 2G4, Canada
[3] Univ Alberta, 2D Walter C Mackenzie Hlth Sci Ctr, Dept Surg, 8440-112 St, Edmonton, AB T6G 2B7, Canada
[4] Univ Alberta, Dept Elect Engn, Donadeo ICE 11 263, 9211-116 St, Edmonton, AB T6G 1H9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
3D ultrasound (3DUS); Image guidance; Motion tracking; Scoliosis; Image registration; ADOLESCENT IDIOPATHIC SCOLIOSIS; ACCURACY; REGISTRATION; CT; PLACEMENT; VERTEBRAE; FUSION;
D O I
10.1007/s11548-021-02516-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Posterior spinal fusion surgery is required to correct severe idiopathic scoliosis. The surgery involves insertion of screws which requires high accuracy to prevent neurologic damage to the spinal cord. Although conventional CT navigation can reduce this risk, 3D-ultrasound-based navigation could achieve this without added ionizing radiation and usage of expensive and bulky equipment. This study aimed to evaluate the accuracy of a 3D ultrasound navigation system for posterior spine surgery. Methods A custom 3D ultrasound (3DUS) with model-to-surface registration algorithm was developed and integrated into a 3D navigation environment. A CT scan of an adolescent spine (T3-T11) was segmented and 3D printed for experiments. A probe with reflective markers was placed in vertebral pedicles 684 times in varying levels, positions in the capture space and orientation of vertebra, and the entrypoint and trajectory accuracies were measured. Results Among 684 probe placements in vertebral levels T3 to T11 in the phantom spine, 95.5% were within 1 mm and 5 degrees of accuracy, with an average accuracy of 0.4 +/- 0.4 mm and 2.1 +/- 0.9 degrees, requiring 8.8 s to process. Accuracies were statistically significantly affected by vertebral orientation and position in the capture volume, though this was still within the targeted accuracies of 1 mm and 5 degrees. Conclusion This preliminary ultrasound-based navigation system is accurate and fast enough for guiding placement of pedicle screws into the spine in posterior fusion surgery. The current results are limited to phantom spines, and future study in animal or human cadavers is needed to investigate soft tissue effects on registration accuracy.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 50 条
  • [31] Is the Use of Intraoperative 3D Navigation for Thoracolumbar Spine Surgery a Risk Factor for Post-Operative Infection?
    Berman, Daniel
    Eleswarapu, Ananth
    Krystal, Jonathan
    Hoang, Henry
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (08)
  • [32] Evaluation of a 2D Fluoroscopy-Based Navigation System for Insertion of the Dynamic Hip Screw (DHS): an Experimental Study
    Mueller, M. C.
    Belei, P.
    de la Fuente, M.
    Strake, M.
    Weber, O.
    Burger, C.
    Radermacher, K.
    Wirtz, D. C.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (06): : 536 - 542
  • [33] A freehand ultrasound framework for spine assessment in 3D: a preliminary study
    Garcia-Cano, Edgar
    Cosio, Fernando Arambula
    Robles, Fabian Torres
    Fanti, Zian
    Bellefleur, Christian
    Joncas, Julie
    Labelle, Hubert
    Duong, Luc
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2096 - 2100
  • [34] Cervical Pedicle Screw Insertion Using O-Arm-Based 3D Navigation: Technical Advancement to Improve Accuracy of Screws
    Wada, Keiji
    Tamaki, Ryo
    Inoue, Tomohisa
    Hagiwara, Kenji
    Okazaki, Ken
    WORLD NEUROSURGERY, 2020, 139 : E182 - E188
  • [35] 3D printed pedicle screw guides reduce the rate of intraoperative screw revision in adolescent idiopathic scoliosis surgery
    Jeong, Seongho
    Yang, Ally
    Dhodapkar, Meera M.
    Jabbouri, Sahir S.
    Jonnalagadda, Anshu
    Tuason, Dominick
    SPINE JOURNAL, 2023, 23 (12) : 1894 - 1899
  • [36] A framework for human spine imaging using a freehand 3D ultrasound system
    Purnama, Ketut E.
    Wilkinson, Michael. H. F.
    Veldhuizen, Albert G.
    van Ooijen, Peter. M. A.
    Lubbers, Jaap
    Burgerhof, Johannes G. M.
    Sardjono, Tri A.
    Verkerke, Gijbertus J.
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (01) : 1 - 17
  • [37] Development of a surgical navigation system based on 3D Slicer for intraoperative implant placement surgery
    Chen, Xiaojun
    Xu, Lu
    Wang, Huixiang
    Wang, Fang
    Wang, Qiugen
    Kikinis, Ron
    MEDICAL ENGINEERING & PHYSICS, 2017, 41 : 81 - 89
  • [38] 3D TENDON STRAIN ESTIMATION ON HIGH-FREQUENCY 3D ULTRASOUND IMAGES A SIMULATION AND PHANTOM STUDY
    Carvalho, C.
    Bogaerts, S.
    Scheys, L.
    D'hooge, J.
    Peers, K.
    Suetens, P.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 172 - 175
  • [39] Evaluation of an Ultrasound-Based Navigation System for Spine Neurosurgery: A Porcine Cadaver Study
    Gueziri, Houssem-Eddine
    Rabau, Oded
    Santaguida, Carlo
    Collins, D. Louis
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [40] 3D Ultrasound Parametric Modeling Imaging for Spine Deformity - A Preliminary Study
    Gao, Yuchong
    Zeng, Hongye
    Zhao, Jianhao
    Zhang, Mingbo
    Zheng, Rui
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,