3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study

被引:6
|
作者
Chan, Andrew [1 ]
Parent, Eric [2 ]
Mahood, Jim [3 ]
Lou, Edmond [1 ,3 ,4 ]
机构
[1] Univ Alberta, Dept Biomed Engn, 1098 Res Transit Facil, 8308-114 St, Edmonton, AB T6G 2V2, Canada
[2] Univ Alberta, Fac Rehabil Med, Dept Phys Therapy, 2-50 Corbett Hall, Edmonton, AB T6G 2G4, Canada
[3] Univ Alberta, 2D Walter C Mackenzie Hlth Sci Ctr, Dept Surg, 8440-112 St, Edmonton, AB T6G 2B7, Canada
[4] Univ Alberta, Dept Elect Engn, Donadeo ICE 11 263, 9211-116 St, Edmonton, AB T6G 1H9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
3D ultrasound (3DUS); Image guidance; Motion tracking; Scoliosis; Image registration; ADOLESCENT IDIOPATHIC SCOLIOSIS; ACCURACY; REGISTRATION; CT; PLACEMENT; VERTEBRAE; FUSION;
D O I
10.1007/s11548-021-02516-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Posterior spinal fusion surgery is required to correct severe idiopathic scoliosis. The surgery involves insertion of screws which requires high accuracy to prevent neurologic damage to the spinal cord. Although conventional CT navigation can reduce this risk, 3D-ultrasound-based navigation could achieve this without added ionizing radiation and usage of expensive and bulky equipment. This study aimed to evaluate the accuracy of a 3D ultrasound navigation system for posterior spine surgery. Methods A custom 3D ultrasound (3DUS) with model-to-surface registration algorithm was developed and integrated into a 3D navigation environment. A CT scan of an adolescent spine (T3-T11) was segmented and 3D printed for experiments. A probe with reflective markers was placed in vertebral pedicles 684 times in varying levels, positions in the capture space and orientation of vertebra, and the entrypoint and trajectory accuracies were measured. Results Among 684 probe placements in vertebral levels T3 to T11 in the phantom spine, 95.5% were within 1 mm and 5 degrees of accuracy, with an average accuracy of 0.4 +/- 0.4 mm and 2.1 +/- 0.9 degrees, requiring 8.8 s to process. Accuracies were statistically significantly affected by vertebral orientation and position in the capture volume, though this was still within the targeted accuracies of 1 mm and 5 degrees. Conclusion This preliminary ultrasound-based navigation system is accurate and fast enough for guiding placement of pedicle screws into the spine in posterior fusion surgery. The current results are limited to phantom spines, and future study in animal or human cadavers is needed to investigate soft tissue effects on registration accuracy.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 50 条
  • [21] An intraoperative 3D image-based navigation error during cervical pedicle screw insertion
    Nakashima, Hiroaki
    Ishikawa, Yoshimoto
    Ando, Kei
    Kobayashi, Kazuyoshi
    Ishiguro, Naoki
    Imagama, Shiro
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2020, 82 (04): : 799 - 805
  • [22] Comparison of Smartphone Augmented Reality, Smartglasses Augmented Reality, and 3D CBCT-guided Fluoroscopy Navigation for Percutaneous Needle Insertion: A Phantom Study
    Long, Dilara J.
    Li, Ming
    De Ruiter, Quirina M. B.
    Hecht, Rachel
    Li, Xiaobai
    Varble, Nicole
    Blain, Maxime
    Kassin, Michael T.
    Sharma, Karun V.
    Sarin, Shawn
    Krishnasamy, Venkatesh P.
    Pritchard, William F.
    Karanian, John W.
    Wood, Bradford J.
    Xu, Sheng
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (05) : 774 - 781
  • [23] The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion
    Deng, Ting
    Jiang, Minghui
    Lei, Qing
    Cai, Lihong
    Chen, Li
    COMPUTER ASSISTED SURGERY, 2016, 21 (01) : 143 - 149
  • [24] 3D printing in spine surgery
    Sheha, Evan D.
    Gandhi, Sapan D.
    Colman, Matthew W.
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7
  • [25] Augmented Reality Spine Surgery Navigation Increasing Pedicle Screw Insertion Accuracy for Both Open and Minimally Invasive Spine Surgeries
    Felix, Brent
    Kalatar, Seyed Babak
    Moatz, Bradley
    Hofstetter, Christoph
    Karsy, Michael
    Parr, Ryan
    Gibby, Wendell
    SPINE, 2022, 47 (12) : 865 - 872
  • [26] Intraoperative 3D Imaging Reduces Pedicle Screw Related Complications and Reoperations in Adolescents Undergoing Posterior Spinal Fusion for Idiopathic Scoliosis: A Retrospective Study
    Saarinen, Antti J.
    Suominen, Eetu N.
    Helenius, Linda
    Syvanen, Johanna
    Raitio, Arimatias
    Helenius, Ilkka
    CHILDREN-BASEL, 2022, 9 (08):
  • [27] 3D printing and spine surgery
    Senkoylu, Alpaslan
    Daldal, Ismail
    Cetinkaya, Mehmet
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (02)
  • [28] Error Analysis for a navigation system using 3D abdominal ultrasound
    Iommi, David
    Valladares, Alejandra
    Figl, Michael
    Hummel, Johann
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [29] Utility of a custom screw insertion guide and a full-scale, color-coded 3D plaster model for guiding safe surgical exposure and screw insertion during spine revision surgery
    Otsuki, Bungo
    Takemoto, Mitsuru
    Fujibayashi, Shunsuke
    Kimura, Hiroaki
    Masamoto, Kazutaka
    Matsuda, Shuichi
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (01) : 94 - 102
  • [30] 3D ultrasound guided navigation system with hybrid image fusion
    Iommi, David
    Valladares, Alejandra
    Figl, Michael
    Grahovac, Marko
    Fichtinger, Gabor
    Hummel, Johann
    SCIENTIFIC REPORTS, 2021, 11 (01)