3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study

被引:6
|
作者
Chan, Andrew [1 ]
Parent, Eric [2 ]
Mahood, Jim [3 ]
Lou, Edmond [1 ,3 ,4 ]
机构
[1] Univ Alberta, Dept Biomed Engn, 1098 Res Transit Facil, 8308-114 St, Edmonton, AB T6G 2V2, Canada
[2] Univ Alberta, Fac Rehabil Med, Dept Phys Therapy, 2-50 Corbett Hall, Edmonton, AB T6G 2G4, Canada
[3] Univ Alberta, 2D Walter C Mackenzie Hlth Sci Ctr, Dept Surg, 8440-112 St, Edmonton, AB T6G 2B7, Canada
[4] Univ Alberta, Dept Elect Engn, Donadeo ICE 11 263, 9211-116 St, Edmonton, AB T6G 1H9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
3D ultrasound (3DUS); Image guidance; Motion tracking; Scoliosis; Image registration; ADOLESCENT IDIOPATHIC SCOLIOSIS; ACCURACY; REGISTRATION; CT; PLACEMENT; VERTEBRAE; FUSION;
D O I
10.1007/s11548-021-02516-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Posterior spinal fusion surgery is required to correct severe idiopathic scoliosis. The surgery involves insertion of screws which requires high accuracy to prevent neurologic damage to the spinal cord. Although conventional CT navigation can reduce this risk, 3D-ultrasound-based navigation could achieve this without added ionizing radiation and usage of expensive and bulky equipment. This study aimed to evaluate the accuracy of a 3D ultrasound navigation system for posterior spine surgery. Methods A custom 3D ultrasound (3DUS) with model-to-surface registration algorithm was developed and integrated into a 3D navigation environment. A CT scan of an adolescent spine (T3-T11) was segmented and 3D printed for experiments. A probe with reflective markers was placed in vertebral pedicles 684 times in varying levels, positions in the capture space and orientation of vertebra, and the entrypoint and trajectory accuracies were measured. Results Among 684 probe placements in vertebral levels T3 to T11 in the phantom spine, 95.5% were within 1 mm and 5 degrees of accuracy, with an average accuracy of 0.4 +/- 0.4 mm and 2.1 +/- 0.9 degrees, requiring 8.8 s to process. Accuracies were statistically significantly affected by vertebral orientation and position in the capture volume, though this was still within the targeted accuracies of 1 mm and 5 degrees. Conclusion This preliminary ultrasound-based navigation system is accurate and fast enough for guiding placement of pedicle screws into the spine in posterior fusion surgery. The current results are limited to phantom spines, and future study in animal or human cadavers is needed to investigate soft tissue effects on registration accuracy.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 50 条
  • [1] 3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study
    Andrew Chan
    Eric Parent
    Jim Mahood
    Edmond Lou
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 271 - 281
  • [2] Accuracy of pedicle screw insertion in posterior scoliosis surgery: a comparison between intraoperative navigation and preoperative navigation techniques
    Zhang, Wei
    Takigawa, Tomoyuki
    Wu, YongGang
    Sugimoto, Yoshihisa
    Tanaka, Masato
    Ozaki, Toshifumi
    EUROPEAN SPINE JOURNAL, 2017, 26 (06) : 1756 - 1764
  • [3] Positional and Orientational Accuracy of 3-D Ultrasound Navigation System on Vertebral Phantom Study
    Ottacher, Drake
    Chan, Andrew
    Parent, Eric
    Lou, Edmond
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) : 6412 - 6419
  • [4] Development and Evaluation of CT-to-3D Ultrasound Image Registration Algorithm in Vertebral Phantoms for Spine Surgery
    Chan, Andrew
    Coutts, Brendan
    Parent, Eric
    Lou, Edmond
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (01) : 310 - 321
  • [5] Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation
    Takao, Masaki
    Hamada, Hidetoshi
    Sakai, Takashi
    Sugano, Nobuhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 189 - 195
  • [6] Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study
    Bredow, Jan
    Meyer, Carolin
    Scheyerer, Max Joseph
    Siedek, Florian
    Mueller, Lars Peter
    Eysel, Peer
    Stein, Gregor
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1683 - 1689
  • [7] Accuracy of pedicle screw insertion in posterior scoliosis surgery: a comparison between intraoperative navigation and preoperative navigation techniques
    Wei Zhang
    Tomoyuki Takigawa
    YongGang Wu
    Yoshihisa Sugimoto
    Masato Tanaka
    Toshifumi Ozaki
    European Spine Journal, 2017, 26 : 1756 - 1764
  • [8] Feasibility of Intraoperative Computed Tomography Navigation System for Pedicle Screw Insertion of the Thoracolumbar Spine
    Lee, Ming-Hsueh
    Lin, Martin Hsiu-Chu
    Weng, Hsu-Huei
    Cheng, Wan-Chun
    Tsai, Yuan-Hsiung
    Wang, Ting-Chung
    Yang, Jen-Tsung
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (05): : E183 - E187
  • [9] Evaluation of 2D and 3D navigation for iliosacral screw fixation
    Behrendt, Daniel
    Muetze, Maria
    Steinke, Hanno
    Koestler, Martin
    Josten, Christoph
    Boehme, Jorg
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 249 - 255
  • [10] 3D Printing in Spine Surgery
    Cai, Hong
    Liu, Zhongjun
    Wei, Feng
    Yu, Miao
    Xu, Nanfang
    Li, Zihe
    INTELLIGENT ORTHOPAEDICS: ARTIFICIAL INTELLIGENCE AND SMART IMAGE-GUIDED TECHNOLOGY FOR ORTHOPAEDICS, 2018, 1093 : 345 - 359