Discrimination between ventricular and supraventricular tachycardia by dual chamber cardioverter defibrillators:: Importance of the atrial sensing function

被引:23
作者
Israel, CW
Grönefeld, G
Iscolo, N
Stöppler, C
Hohnloser, SH
机构
[1] Goethe Univ Frankfurt, Dept Med, Div Cardiol, D-60590 Frankfurt, Germany
[2] Ela Rech, Le Plessis Robinson, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 02期
关键词
implantable cardioverter defibrillator; dual chamber; detection algorithms; atrial sensing; ventricular tachycardia; supraventricular tachycardia;
D O I
10.1046/j.1460-9592.2001.00183.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the addition of atrial sensing in dual chamber ICDs may improve the ability of the device to discriminate between supraventricular (SVT) and ventricular tachycardia (VT), atrial sensing errors may also negatively affect tachycardia classification. This prospective study evaluated the incidence of a trial sensing errors in a dual chamber ICD and their impact on VT/SVT discrimination. in 145 patients, a dual chamber ICD (Defender) was implanted. Analysis of 1,241 tachycardia episodes stored during a mean follow-up of 14 +/- 8 months revealed atrial sensing errors in 827 (66%) episodes. Upon expert review device-based classification was confirmed in 509 (98%) of 522 SVT episodes. No false device-based SVT classification was related to atrial sensing errors. Of 719 episodes classified as VT by the device, 645 (90%) were confirmed. There were 74 episodes of false-positive VT detection. Of these, 63 were related to atrial sensing errors: atrial under sensing in 58 (92%) and atrial oversensing in 5 (8%) episodes. Atrial sensing errors led to incorrect VT/SVT discrimination in 51 (4%) of 1,241 episodes. Only the occurrence of paroxysmal atrial fibrillation and abdominal site of device implantation showed a significant influence on false VT/SVT discrimination. Atrial sensing errors are frequently encountered in dual chamber ICDs. Due to the VT/SVT discrimination algorithm, atrial sensing errors only led to misclassification in 4% of all episodes, mainly due to atrial undersensing. No VT underdetection due to atrial oversensing occurred.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 41 条
[21]  
KHANTARIA B, 1999, PACE, V22, P824
[22]   Intracardiac QRS electrogram width - An arrhythmia detection feature for implantable cardioverter defibrillators: Exercise induced variation as a base for device programming [J].
Klingenheben, T ;
Sticherling, C ;
Skupin, M ;
Hohnloser, SH .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08) :1609-1617
[23]   A new classification algorithm for discrimination of ventricular from supraventricular tachycardia in a dual chamber implantable cardioverter defibrillator [J].
Korte, T ;
Jung, W ;
Wolpert, C ;
Spehl, S ;
Schumacher, B ;
Esmailzadeh, B ;
Lüderitz, B .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (01) :70-73
[24]   Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing [J].
Kühlkamp, V ;
Dörnberger, V ;
Mewis, C ;
Suchalla, R ;
Bosch, RF ;
Seipel, L .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (07) :905-915
[25]   Preliminary clinical experience with the first dual chamber pacemaker defibrillator [J].
Lavergne, T ;
Daubert, JC ;
Chauvin, M ;
Dolla, E ;
Kacet, S ;
Leenhardt, A ;
Mabo, P ;
Ritter, P ;
Sadoul, N ;
Saoudi, N ;
Henry, C ;
Nitzsche, R ;
Ripart, A ;
Murgatroyd, F .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :182-188
[26]  
Le Franc P, 1997, PACE, V20, P2882
[27]  
LEMKE B, 1985, HERZSCHRITTMACHER, V5, P111
[28]   COMPLICATIONS AFTER SINGLE VERSUS DUAL CHAMBER PACEMAKER IMPLANTATION [J].
MUELLER, X ;
SADEGHI, H ;
KAPPENBERGER, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (06) :711-714
[29]  
Nair M, 1997, CIRCULATION, V95, P967
[30]   PROGRAMMABLE VT DETECTION ENHANCEMENTS IN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY [J].
NEUZNER, J ;
PITSCHNER, HF ;
SCHLEPPER, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (03) :539-547