Radioguided occult lesion localisation (ROLL) is available in the UK for impalpable breast lesions

被引:24
|
作者
Audisio, RA [1 ]
Nadeem, R
Harris, O
Desmond, S
Thind, R
Chagla, LS
机构
[1] Whiston Hosp, Dept Gen Surg, Prescot L35 5DR, Merseyside, England
[2] Whiston Hosp, Dept Surg, Prescot L35 5DR, Merseyside, England
[3] Whiston Hosp, Dept Radiol, Prescot L35 5DR, Merseyside, England
关键词
sub-clinical breast neoplasms; ROLL; radioguided surgery;
D O I
10.1308/1478708051595
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: To test the feasibility and reliability of ROLL in a district general hospital (DGH) dealing with screening detected breast lesions. Patients and Methods: [Tc-99m]-labelled colloidal human serum albumin was injected in the core of the breast lesion under ultrasound or stereotactic guidance 2-4 h prior to surgery. At operation, the radioactivity is localised using a gamma-probe. This allows optimal placement of the skin incision and subsequent WLE of the abnormal area. Results: ROLL was utilised on 36 patients (median age, 61 years; range, 43-75 years); of these, 33 B5 lesions had a therapeutic one-step procedure (lumpectomy and axillary dissection) and 3 B4 patients had the lesion excised for diagnostic purposes. Localisation lasted a median of 8 min (range, 5-15 min), ROLL-guided wide tumour excision lasted 20 min (range, 15-30 min), and median postoperative hospital stay was 2 days (range, 1-3 days). Median cancer diameter was 12 mm (range, 6-40 mm). Margins were clear in 29 patients, while 7 patients with DClS had involved margins. Median minimal clearance was 5 mm (range, < 1-10 mm). Patients had either excellent (24/36) or good (12/36) cosmetic results. Conclusions: ROLL successfully localised all lesions; this technique can be implemented in any DGH with a Nuclear Medicine Department. The learning curve is short, cost effectiveness is proven, and cosmetic results are highly rewarding. ROLL could rapidly become the standard localisation technique in the UK.
引用
收藏
页码:92 / 95
页数:4
相关论文
共 44 条
  • [41] The use of radioactive iodine-125 seed localization in patients with non-palpable breast cancer: A comparison with the radioguided occult lesion localization with 99m technetium
    van der Noordaa, M. E. M.
    Pengel, K. E.
    Groen, E.
    van Werkhoven, E.
    Rutgers, E. J. Th.
    Loo, C. E.
    Vogel, W.
    Peeters, M. J. T. F. D. Vrancken
    EJSO, 2015, 41 (04): : 553 - 558
  • [42] Survey of the Radioguided Surgery Working Group (GTCRG-RGSWG) of the Spanish Society of Nuclear Medicine and Molecular Imaging (SEMNIM): Radioguided localization of non-palpable breast lesions with or without indication for selective sentinel node biopsy: ROLL, SNOLL and 125I seeds
    Perez, P. A. de la Riva
    Salazar, D. Carrera
    Barranco, P. Paredes
    Girones, E. Goni
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2022, 41 (04): : 223 - 230
  • [43] Radioguided occult lesion localization plus sentinel node biopsy (SNOLL) versus wire-guided localization plus sentinel node detection: A case control study of 129 unifocal pure invasive non-palpable breast cancers
    Giacalone, P. L.
    Bourdon, A.
    Trinh, P. D.
    Taourel, P.
    Rathat, G.
    Sainmont, M.
    Perocchia, H.
    Rossi, M.
    Rouleau, C.
    EJSO, 2012, 38 (03): : 222 - 229
  • [44] Use of wire-guided and radio-guided occult lesion localization for non-palpable breast lesions: A systematic literature review and meta-analysis of current evidence
    Kiruparan, Nanthesh
    Kiruparan, Pasupathy
    Debnath, Debasish
    ASIAN JOURNAL OF SURGERY, 2022, 45 (01) : 79 - 88