Enhancing micro gas turbine performance in hot climates through inlet air cooling vapour compression technique

被引:31
作者
Comodi, G. [1 ]
Renzi, M. [2 ]
Caresana, F. [1 ]
Pelagalli, L. [1 ]
机构
[1] Univ Politecn Marche, Dipartimento Ingn Ind & Sci Matemat, I-60131 Ancona, Italy
[2] Libera Univ Bolzano, Fac Sci & Tecnol, I-39100 Bolzano, Italy
关键词
Micro turbines; Inlet air cooling; Distributed generation; Electrical efficiency; Hot climates; Direct expansion; DISTRIBUTED GENERATION; SYSTEM; MICROTURBINE; BENEFITS; ENHANCEMENT; ENGINES; IMPACT; HEAT;
D O I
10.1016/j.apenergy.2015.02.076
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Microturbines (MGTs) are power generation devices showing very interesting performance in terms of low environmental impact, high-grade waste heat and very low maintenance cost. One of the main issues that affect the output of MGTs is their strong sensibility to inlet air temperature. Both in literature and in practical applications, several solutions have been applied to control the inlet air conditions and reduce the sensibility of this kind of machines to ambient conditions. One of the most interesting technology is the refrigerating vapour compression technique. This solution has already been used for medium/large GTs, but there are very limited inlet air cooling applications on MGTs and few experimental data are documented. This paper describes a test bench that has been designed to apply the direct vapour expansion technique to a 100 kWe MGT and reports the power and efficiency augmentation of the machine when operating in hot summer days. The chiller was designed to treat the MGT's air flow rate under specific working conditions and cool the inlet air temperature down to 15 degrees C. Thanks to the reduction of the inlet air temperature, the MGT showed a benefit in terms of electric power gain up to 8% with respect to the nominal power output in ISO conditions while the electric efficiency increased by 1.5%. Results indicate that an almost linear trend can be obtained both in the electric power increase and in the electric efficiency increase as a function of the inlet air temperature when the chiller operates under nominal working conditions. When the IAC device operates at a higher temperature or a higher humidity than the design one, the gain is limited; in some working conditions with high relative humidity, most of the beneficial effect can even be lost. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:40 / 48
页数:9
相关论文
共 39 条
[1]   Impact of the use of a hybrid turbine inlet air cooling system in arid climates [J].
Al-Ansary, Hany A. ;
Orfi, Jamel A. ;
Ali, Mohamed E. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 75 :214-223
[2]   A review of inlet air-cooling technologies for enhancing the performance of combustion turbines in Saudi Arabia [J].
Al-Ibrahim, Abdulrahman M. ;
Varnham, Abdulhadi .
APPLIED THERMAL ENGINEERING, 2010, 30 (14-15) :1879-1888
[3]   Influence of the relative humidity on the air cooling thermal load in gas turbine power plant [J].
Amell, AA ;
Cadavid, FJ .
APPLIED THERMAL ENGINEERING, 2002, 22 (13) :1529-1533
[4]  
Andrepont J.S., 2001, ASHRAE T, V107, P892
[5]  
[Anonymous], 2008, ASHRAE HDB HVAC SYST, P171
[6]   Application of artificial neural networks to micro gas turbines [J].
Bartolini, C. M. ;
Caresana, F. ;
Comodi, G. ;
Pelagalli, L. ;
Renzi, M. ;
Vagni, S. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :781-788
[7]   Effect of ambient temperature on the performance of micro gas turbine with cogeneration system in cold region [J].
Basrawi, Firdaus ;
Yamada, Takanobu ;
Nakanishi, Kimio ;
Naing, Soe .
APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) :1058-1067
[8]   Potential renewable energy resources of the Lerma Valley, Salta, Argentina for its strategic territorial planning [J].
Belmonte, S. ;
Nunez, V. ;
Viramonte, J. G. ;
Franco, J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (6-7) :1475-1484
[9]   Microturbogas cogeneration systems for distributed generation: Effects of ambient temperature on global performance and components' behavior [J].
Caresana, F. ;
Pelagalli, L. ;
Comodi, G. ;
Renzi, M. .
APPLIED ENERGY, 2014, 124 :17-27
[10]   Use of a test-bed to study the performance of micro gas turbines for cogeneration applications [J].
Caresana, Flavio ;
Comodi, Gabriele ;
Pelagalli, Leonardo ;
Renzi, Massimiliano ;
Vagni, Sandro .
APPLIED THERMAL ENGINEERING, 2011, 31 (16) :3552-3558