Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging - art. no. 69181V

被引:8
作者
Sherman, J. R. [1 ]
Rangwala, H. S. [1 ]
Ionita, C. N. [1 ]
Dohatcu, A. C. [1 ]
Lee, J. W. [1 ]
Bednarek, D. R. [1 ]
Hoffmann, K. R. [1 ]
Rudin, S. [1 ]
机构
[1] SUNY Buffalo, Toshiba Stroke Res Ctr, Buffalo, NY 14214 USA
来源
MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2 | 2008年 / 6918卷
关键词
image-guided therapy; neurosurgical procedures; modeling; procedure simulation; segmentation and rendering; treatment planning;
D O I
10.1117/12.772583
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Effective minimally invasive treatment of cerebral bifurcation aneurysms is challenging due to the complex and remote vessel morphology. An evaluation of endovascular treatment in a phantom involving image-guided deployment of new asymmetric stents consisting of polyurethane patches placed to modify blood flow into the aneurysm is reported. The 3D lumen-geometry of a patient-specific basilar-artery bifurcation aneurysm was derived from a segmented computed-tomography dataset. This was used in a stereolithographic rapid-prototyping process to generate a mold which was then used to create any number of exact wax models. These models in turn were used in a lost-wax technique to create transparent elastomer patient-specific aneurysm phantoms (PSAP) for evaluating the effectiveness of asymmetric-stent deployment for flow modification. Flow was studied by recording real-time digitized video images of optical dye in the PSAP and its feeding vessel. For two asymmetric stent placements: through the basilar into the right-posterior communicating artery (RPCA) and through the basilar into the left-posterior communicating artery (LPCA), the greatest deviation of flow streamlines away from the aneurysm occurred for the RPCA stent deployment. Flow was also substantially affected by variations of inflow angle into the basilar artery, resulting in alternations in washout times as derived from time-density curves. Evaluation of flow in the PSAPs with real-time optical imaging can be used to determine new EIGI effectiveness and to validate computational-fluid-dynamic calculations for EIGI-treatment planning.
引用
收藏
页码:V9181 / V9181
页数:11
相关论文
共 12 条
[1]   Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils [J].
Bavinzski, G ;
Talazoglu, V ;
Killer, M ;
Richling, B ;
Gruber, A ;
Gross, CE ;
Plenk, H .
JOURNAL OF NEUROSURGERY, 1999, 91 (02) :284-293
[2]  
DOEFLER A, 2004, J NEUROSUGERY, V100, P150
[3]   DETERMINATION OF INSTANTANEOUS AND AVERAGE BLOOD-FLOW RATES FROM DIGITAL ANGIOGRAMS OF VESSEL PHANTOMS USING DISTANCE-DENSITY CURVES [J].
HOFFMANN, KR ;
DOI, K ;
FENCIL, LE .
INVESTIGATIVE RADIOLOGY, 1991, 26 (03) :207-212
[4]  
IONITA CN, 2008, SPIE
[5]  
KELESHIS C, 2008, SPIE
[6]  
Langille B.L., 1995, FLOW DEPENDENT REGUL, P277
[7]   Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity [J].
Lieber, BB ;
Stancampiano, AP ;
Wakhloo, AK .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (03) :460-469
[8]   Measurement of flow modification in phantom aneurysm model: Comparison of coils and a longitudinally and axially asymmetric stent - Initial findings [J].
Rudin, S ;
Wang, Z ;
Kyprianou, I ;
Hoffmann, KR ;
Wu, Y ;
Meng, H ;
Guterman, LR ;
Nemes, B ;
Bednarek, DR ;
Dmochowski, J ;
Hopkins, LN .
RADIOLOGY, 2004, 231 (01) :272-276
[9]   Finite-element modeling of the hemodynamics of stented aneurysms [J].
Stuhne, GR ;
Steinman, DA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (03) :382-387
[10]  
Szycher M., 2013, Szycher's Handbook of Polyurethanes