Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the analysis of paroxetine in human plasma

被引:46
作者
Weng, ND [1 ]
Eerkes, A [1 ]
机构
[1] Covance Labs Inc, Madison, WI 53706 USA
关键词
paroxetine HILIC-MS/MS; human plasma; paroxetine;
D O I
10.1002/bmc.288
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, simple, fast and rugged hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the determination of paroxetine was developed and validated over curve range 0.050-50 ng/mL using only 0.4 mL plasma. This is the first published LC-MS/MS method and the low limit of quantitation of this method is 10-fold lower than previously published methods. A simple liquid-liquid extraction method using methyl-tert butyl ether (MTBE) as the extraction solvent was used to extract paroxetine and the internal standard (IS) fentanyl-d(5) from plasma. The extract was evaporated to dryness, reconstituted and injected onto a silica column using a low aqueous-high organic mobile phase. The chromatographic run time was 2.0 min per injection, with retention times of 1.1 and 1.2 min for paroxetine and IS, respectively. The detection was by monitoring paroxetine at m/z 330 --> 192 and IS at m/z 342 --> 188, respectively. The inter-day precision and accuracy of the quality control (QC) samples were <5.0% relative standard deviation (RSD) and <2.9% relative error (RE). This method can be used for supporting therapeutical drug monitoring and pharmacokinetic or drug-drug interaction studies. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 42 条
[1]  
[Anonymous], 1997, ELECTROSPRAY IONIZAT
[2]   Determination of fluvoxamine and paroxetine in human serum with highperformance liquid chromatography and ultraviolet detection [J].
Bagli, M ;
Rao, ML ;
Sobanski, T ;
Laux, G .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (02) :283-295
[3]   THE ROLE OF CYTOCHROME-P4502D6 IN THE METABOLISM OF PAROXETINE BY HUMAN LIVER-MICROSOMES [J].
BLOOMER, JC ;
WOODS, FR ;
HADDOCK, RE ;
LENNARD, MS ;
TUCKER, GT .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 33 (05) :521-523
[4]  
BROSEN K, 1993, CLIN INVESTIGATOR, V71, P1002
[5]   Hydrophilic interaction liquid chromatography/electrospray mass spectrometry determination of acyclovir in pregnant rat plasma and tissues [J].
Brown, SD ;
White, CA ;
Bartlett, MG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (19) :1871-1876
[6]   Simultaneous determination of hydrocodone and hydromorphone in human plasma by liquid chromatography with tandem mass spectrometric detection [J].
Chen, YL ;
Hanson, GD ;
Jiang, XY ;
Weng, ND .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (01) :55-64
[7]   A high-pressure liquid chromatographic-tandem mass spectrometric method for the determination of ethambutol in human plasma, bronchoalveolar lavage fluid, and alveolar cells [J].
Conte, JE ;
Lin, E ;
Zhao, YP ;
Zurlinden, E .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (02) :113-118
[8]   High-performance liquid chromatographic-tandem mass spectrometric method for the determination of ethionamide in human plasma, bronchoalveolar lavage fluid and alveolar cells [J].
Conte, JE ;
Wang, GF ;
Lin, ET ;
Zurlinden, E .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02) :343-353
[9]   Analytical methods for the quantitative determination of selective serotonin reuptake inhibitors for therapeutic drug monitoring purposes in patients [J].
Eap, CB ;
Baumann, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 686 (01) :51-63
[10]   Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma [J].
Eerkes, A ;
Shou, WZ ;
Weng, ND .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) :917-928